HTabGroup

A - Z (Full Detail)
Displaying 101 - 110 of 2252

If no results are displayed, please adjust your choices on the left. The first selections might be slow, as there are thousands of records to load! As you select, each remaining search parameter will recalculate.

BBC5PA-B02XCI-0400X-X11

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
0.1 - 5 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Panel mount: Imperial
Termination: 
Clamp
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Fast
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Paddle Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Clamp Terminal
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 4A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Order Sample

BBC5PA-B02XCI-0700X-X11

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
6 - 15 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Panel mount: Imperial
Termination: 
Clamp
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Fast
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Paddle Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Clamp Terminal
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 7A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Order Sample

BBC5PA-B02XCI-1000X-X11

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
6 - 15 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Panel mount: Imperial
Termination: 
Clamp
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Fast
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Paddle Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Clamp Terminal
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Order Sample

BBC5PA-B02XCI-1250X-X11

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
6 - 15 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Panel mount: Imperial
Termination: 
Clamp
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Fast
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Paddle Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Clamp Terminal
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 12.5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Order Sample

BBC5PA-B02XCI-1800X-X12

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
16 - 30 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Panel mount: Imperial
Termination: 
Clamp
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Fast
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Paddle Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Clamp Terminal
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 18A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark
Order Sample

BBC5PA-B02XCI-2500X-X11

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
16 - 30 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Panel mount: Imperial
Termination: 
Clamp
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Fast
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Paddle Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Clamp Terminal
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Order Sample

BBC5PA-B03XCI-1000X-X11

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
6 - 15 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Panel mount: Imperial
Termination: 
Clamp
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Fast
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Paddle Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Clamp Terminal
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Order Sample

BBC5PA-B03XCI-1250X-X11

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
6 - 15 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Panel mount: Imperial
Termination: 
Clamp
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Fast
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Paddle Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Clamp Terminal
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 12.5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Order Sample

BBC5PA-B07XCI-0700X-X12

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
6 - 15 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Panel mount: Imperial
Termination: 
Clamp
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Fast
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Paddle Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Clamp Terminal
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Red (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 7A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark
Order Sample

BBC5ZA-B04XCI-2000X-X12

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
16 - 30 A
Frequency: 
AC only
Mounting: 
Panel mount: Imperial
Termination: 
Clamp
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Fast
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Paddle Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Clamp Terminal
  • Rated Voltage - Main Circuit: Special (Specify)
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Blue (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark
Order Sample

Pages

Accordion View
Displaying 501 - 550 of 2252

If no results are displayed, please adjust your choices on the left. The first selections might be slow, as there are thousands of records to load! As you select, each remaining search parameter will recalculate.

Part No: BFA1FD-B0ZXCS-3000X-X32

Frame: B-Frame
  • Frame and Handle:Black Body, Push-to-Reset Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit:80V Polarity Sensitive (0.6kA) MKI
  • Frequency:DC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:Special (Specify)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Short Time Delay
  • Main Circuit Current Ratings:30A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL 489A, UL508, IEC60934,VDE & CE
  • Safety Marks: No Safety Mark

Part No: BFA1PA-B02XAI-1900X-X12

Frame: B-Frame
  • Frame and Handle:Black Body, Push-to-Reset Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit:240V (1kA) MKII
  • Frequency:AC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:White (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings:19A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BFA1PA-B02XAI-3000X-X11

Frame: B-Frame
  • Frame and Handle:Black Body, Push-to-Reset Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit:240V (1kA) MKII
  • Frequency:AC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:White (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings:30A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BFA1PA-B02XAS-0250X-X12

Frame: B-Frame
  • Frame and Handle:Black Body, Push-to-Reset Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit:240V (1kA) MKII
  • Frequency:AC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:White (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay
  • Main Circuit Current Ratings:2.5A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BFA1PA-B02XAS-0400X-X12

Frame: B-Frame
  • Frame and Handle:Black Body, Push-to-Reset Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit:240V (1kA) MKII
  • Frequency:AC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:White (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay
  • Main Circuit Current Ratings:4A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BFA1PA-B02XAS-2000X-X12

Frame: B-Frame
  • Frame and Handle:Black Body, Push-to-Reset Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit:240V (1kA) MKII
  • Frequency:AC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:White (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay
  • Main Circuit Current Ratings:20A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BFA1PA-B02XBS-0120X-X11

Frame: B-Frame
  • Frame and Handle:Black Body, Push-to-Reset Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit:240V (1kA) MKII
  • Frequency:AC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:White (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Medium Time Delay
  • Main Circuit Current Ratings:1.2A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BFA1PA-B02XBS-1500X-X12

Frame: B-Frame
  • Frame and Handle:Black Body, Push-to-Reset Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit:240V (1kA) MKII
  • Frequency:AC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:White (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Medium Time Delay
  • Main Circuit Current Ratings:15A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BFA1PA-B02XBS-3000X-X12

Frame: B-Frame
  • Frame and Handle:Black Body, Push-to-Reset Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit:240V (1kA) MKII
  • Frequency:AC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:White (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Medium Time Delay
  • Main Circuit Current Ratings:30A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BFA1PA-B03XAI-0900X-XXX

Frame: B-Frame
  • Frame and Handle:Black Body, Push-to-Reset Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit:240V (1kA) MKII
  • Frequency:AC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:Black (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings:9A
  • Relay Trip Coils:Not Applicable

Part No: BFA1PA-B03XCS-1500X-X11

Frame: B-Frame
  • Frame and Handle:Black Body, Push-to-Reset Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit:240V (1kA) MKII
  • Frequency:AC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:Black (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Short Time Delay
  • Main Circuit Current Ratings:15A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BFA1PA-B0ZXBS-1000X-XXX

Frame: B-Frame
  • Frame and Handle:Black Body, Push-to-Reset Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit:240V (1kA) MKII
  • Frequency:AC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:Special (Specify)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Medium Time Delay
  • Main Circuit Current Ratings:10A
  • Relay Trip Coils:Not Applicable

Part No: BFAAPA-B02XAS-0500X-X12

Frame: B-Frame
  • Frame and Handle:Black Body, Push-to-Reset Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit with 90 Deg. Bent Terminal
  • Rated Voltage - Main Circuit:240V (1kA) MKII
  • Frequency:AC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:White (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay
  • Main Circuit Current Ratings:5A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BFACED-B02XCS-2500X-X12

Frame: B-Frame
  • Frame and Handle:Black Body, Push-to-Reset Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit, Screw Terminal
  • Rated Voltage - Main Circuit:65V DC (0.5kA) MKII
  • Frequency:DC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:White (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Short Time Delay
  • Main Circuit Current Ratings:25A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BFACMM-B02XBW-1300X-X11

Frame: B-Frame
  • Frame and Handle:Black Body, Push-to-Reset Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit, Screw Terminal
  • Rated Voltage - Main Circuit:65V DC / 240V AC MKII
  • Frequency:AC / DC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:White (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Medium Time Delay (BD + Inertia Delay)
  • Main Circuit Current Ratings:13A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BFACMM-B03XAD-2500X-X12

Frame: B-Frame
  • Frame and Handle:Black Body, Push-to-Reset Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit, Screw Terminal
  • Rated Voltage - Main Circuit:65V DC / 240V AC MKII
  • Frequency:AC / DC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:Black (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay (Dual Rated)
  • Main Circuit Current Ratings:25A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BFACPA-B02XAS-1000X-X11

Frame: B-Frame
  • Frame and Handle:Black Body, Push-to-Reset Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit, Screw Terminal
  • Rated Voltage - Main Circuit:240V (1kA) MKII
  • Frequency:AC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:White (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay
  • Main Circuit Current Ratings:10A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BFACPA-B02XAS-2000X-X11

Frame: B-Frame
  • Frame and Handle:Black Body, Push-to-Reset Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit, Screw Terminal
  • Rated Voltage - Main Circuit:240V (1kA) MKII
  • Frequency:AC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:White (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay
  • Main Circuit Current Ratings:20A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BFACPA-B03XBS-1600X-X11

Frame: B-Frame
  • Frame and Handle:Black Body, Push-to-Reset Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit, Screw Terminal
  • Rated Voltage - Main Circuit:240V (1kA) MKII
  • Frequency:AC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:Black (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Medium Time Delay
  • Main Circuit Current Ratings:16A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BFC1ED-B03XAS-0500X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BFC1ED-B03XAS-0800X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 8A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BFC1MM-B03XBD-0400X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
  • Main Circuit Current Ratings: 4A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BFC1MM-B0ZXBD-1500X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Special (Specify)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BFC1MM-B0ZXBD-3000X-X22

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Special (Specify)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
  • Main Circuit Current Ratings: 30A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: No approvals required, refer to ticksheet
  • Safety Marks: No Safety Mark

Part No: BFC1PA-B03XBS-2000X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BFC1PA-B0ZXCS-0100X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Special (Specify)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 1A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BFC1ZA-B02XAI-2500X-XXX

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: Special (Specify)
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable

Part No: BFC5ED-B02XBI-2500X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Clamp Terminal
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BFCCFD-B03XCS-1500X-X31

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Screw Terminal
  • Rated Voltage - Main Circuit: 80V Polarity Sensitive (0.6kA) MKI
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL 489A, UL508, IEC60934,VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BFCCPA-B02XCI-2500X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Screw Terminal
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BFQ1ED-B02XBS-0750X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 7.5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BFQ1ED-B02XBS-1500X-XXX

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable

Part No: BFQ1ED-B02XBS-2500X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BFQ1ED-B02XCS-0100X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 1A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BFQ1ED-B02XCS-0250X-XXX

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 2.5A
  • Relay Trip Coils: Not Applicable

Part No: BFQ1ED-B02XCS-0400X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 4A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BFQ1ED-B02XCS-1000X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BFQ1ED-B02XOP-0400X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Instantaneous
  • Main Circuit Current Ratings: 4A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BFQ1ED-B02XOP-0500X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Instantaneous
  • Main Circuit Current Ratings: 5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BFQ1ED-B12XCS-0400X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 4A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BFQ1ED-B12XCS-1000X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BFQ1ED-B13XBS-0050X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 0.5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BFQ1ED-D02XOX-2500D0-2412

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Relay Trip (Voltage Sensing)
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Switch
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: 24V DC
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BFQ1MM-B02XBD-0200X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
  • Main Circuit Current Ratings: 2A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BFQ1MM-B02XBD-0500X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
  • Main Circuit Current Ratings: 5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BFQ1PA-B02XAI-0400X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 4A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BFQ1PA-B02XAI-1000X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BFQ1PA-B02XAI-1200X-XXX

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 12A
  • Relay Trip Coils: Not Applicable

Part No: BFQ1PA-B02XAI-2500X-XXX

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable

Part No: BFQ1PA-B02XAS-0300X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 3A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Pages

List View
Displaying 301 - 330 of 2252

If no results are displayed, please adjust your choices on the left. The first selections might be slow, as there are thousands of records to load! As you select, each remaining search parameter will recalculate.

Part No No of Poles Framesort descending View/Order Termination
BBC1MM-B13XBD-1500X-X12 1 B-Frame Quick connect
BBC1PA-B01XCI-0400X-X11 1 B-Frame Quick connect
BBC1PA-B02XCI-1000X-X12 1 B-Frame Quick connect
BBC1PA-B02XCI-1250X-X11 1 B-Frame Quick connect
BBC1PA-B02XCI-0400X-X12 1 B-Frame Quick connect
BBC1PA-B02XCI-0600X-X12 1 B-Frame Quick connect
BBC1PA-B02XCI-0700X-X11 1 B-Frame Quick connect
BBC1PA-B02XCS-1700X-X11 1 B-Frame Quick connect
BBC1PA-B02XCS-0900X-X11 1 B-Frame Quick connect
BBC1PA-B03XAI-1000X-X11 1 B-Frame Quick connect
BBC1PA-B03XBS-1000X-X11 1 B-Frame Quick connect
BBC1PA-B03XBS-1500X-X11 1 B-Frame Quick connect
BBC1PA-B03XBS-2500X-X11 1 B-Frame Quick connect
BBC1PA-B03XCI-1250X-X11 1 B-Frame Quick connect
BBC1PA-B07XBI-0300X-XXX 1 B-Frame Quick connect
BBC1PA-B07XCI-1000X-X11 1 B-Frame Quick connect
BBC1PA-B07XCI-2000X-X11 1 B-Frame Quick connect
BBC1PA-B07XCI-2500X-X11 1 B-Frame Quick connect
BBC1PA-B08XAI-1250X-X11 1 B-Frame Quick connect
BBC1ZA-B01XCI-0500X-XXX 1 B-Frame Quick connect
BBC1ZA-B02XAI-2500X-XXX 1 B-Frame Quick connect
BBC1ZA-B02XBI-2500X-X12 1 B-Frame Quick connect
BBC1ZA-B03XAI-1000X-X12 1 B-Frame Quick connect
BBC1ZA-B03XCI-1000X-XXX 1 B-Frame Quick connect
BBC1ZA-B06XAI-1500X-X12 1 B-Frame Quick connect
BBC1ZA-B06XCI-1500X-XXX 1 B-Frame Quick connect
BBC1ZA-B08XAI-1250X-X12 1 B-Frame Quick connect
BBC5PA-B01XCI-0500X-X11 1 B-Frame Clamp
BBC5PA-B02XCI-1000X-X11 1 B-Frame Clamp
BBC5PA-B02XCI-0100X-X12 1 B-Frame Clamp

Pages

Keyword Search

Add a space to represent gaps between sections of a part number

Displaying 501 - 550 of 2247

BFA1PA-B02XAS-2000X-X12

Frame: B-Frame
  • Frame and Handle:Black Body, Push-to-Reset Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit:240V (1kA) MKII
  • Frequency:AC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:White (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay
  • Main Circuit Current Ratings:20A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFA1PA-B02XBS-0120X-X11

Frame: B-Frame
  • Frame and Handle:Black Body, Push-to-Reset Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit:240V (1kA) MKII
  • Frequency:AC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:White (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Medium Time Delay
  • Main Circuit Current Ratings:1.2A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BFA1PA-B02XBS-1500X-X12

Frame: B-Frame
  • Frame and Handle:Black Body, Push-to-Reset Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit:240V (1kA) MKII
  • Frequency:AC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:White (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Medium Time Delay
  • Main Circuit Current Ratings:15A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFA1PA-B02XBS-3000X-X12

Frame: B-Frame
  • Frame and Handle:Black Body, Push-to-Reset Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit:240V (1kA) MKII
  • Frequency:AC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:White (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Medium Time Delay
  • Main Circuit Current Ratings:30A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFA1PA-B03XAI-0900X-XXX

Frame: B-Frame
  • Frame and Handle:Black Body, Push-to-Reset Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit:240V (1kA) MKII
  • Frequency:AC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:Black (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings:9A
  • Relay Trip Coils:Not Applicable

BFA1PA-B03XCS-1500X-X11

Frame: B-Frame
  • Frame and Handle:Black Body, Push-to-Reset Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit:240V (1kA) MKII
  • Frequency:AC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:Black (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Short Time Delay
  • Main Circuit Current Ratings:15A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BFA1PA-B0ZXBS-1000X-XXX

Frame: B-Frame
  • Frame and Handle:Black Body, Push-to-Reset Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit:240V (1kA) MKII
  • Frequency:AC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:Special (Specify)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Medium Time Delay
  • Main Circuit Current Ratings:10A
  • Relay Trip Coils:Not Applicable

BFAAPA-B02XAS-0500X-X12

Frame: B-Frame
  • Frame and Handle:Black Body, Push-to-Reset Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit with 90 Deg. Bent Terminal
  • Rated Voltage - Main Circuit:240V (1kA) MKII
  • Frequency:AC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:White (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay
  • Main Circuit Current Ratings:5A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFACED-B02XCS-2500X-X12

Frame: B-Frame
  • Frame and Handle:Black Body, Push-to-Reset Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit, Screw Terminal
  • Rated Voltage - Main Circuit:65V DC (0.5kA) MKII
  • Frequency:DC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:White (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Short Time Delay
  • Main Circuit Current Ratings:25A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFACMM-B02XBW-1300X-X11

Frame: B-Frame
  • Frame and Handle:Black Body, Push-to-Reset Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit, Screw Terminal
  • Rated Voltage - Main Circuit:65V DC / 240V AC MKII
  • Frequency:AC / DC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:White (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Medium Time Delay (BD + Inertia Delay)
  • Main Circuit Current Ratings:13A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BFACMM-B03XAD-2500X-X12

Frame: B-Frame
  • Frame and Handle:Black Body, Push-to-Reset Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit, Screw Terminal
  • Rated Voltage - Main Circuit:65V DC / 240V AC MKII
  • Frequency:AC / DC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:Black (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay (Dual Rated)
  • Main Circuit Current Ratings:25A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFACPA-B02XAS-1000X-X11

Frame: B-Frame
  • Frame and Handle:Black Body, Push-to-Reset Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit, Screw Terminal
  • Rated Voltage - Main Circuit:240V (1kA) MKII
  • Frequency:AC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:White (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay
  • Main Circuit Current Ratings:10A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BFACPA-B02XAS-2000X-X11

Frame: B-Frame
  • Frame and Handle:Black Body, Push-to-Reset Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit, Screw Terminal
  • Rated Voltage - Main Circuit:240V (1kA) MKII
  • Frequency:AC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:White (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay
  • Main Circuit Current Ratings:20A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BFACPA-B03XBS-1600X-X11

Frame: B-Frame
  • Frame and Handle:Black Body, Push-to-Reset Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit, Screw Terminal
  • Rated Voltage - Main Circuit:240V (1kA) MKII
  • Frequency:AC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:Black (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Medium Time Delay
  • Main Circuit Current Ratings:16A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BFC1ED-B03XAS-0500X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFC1ED-B03XAS-0800X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 8A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFC1MM-B03XBD-0400X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
  • Main Circuit Current Ratings: 4A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFC1MM-B0ZXBD-1500X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Special (Specify)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFC1MM-B0ZXBD-3000X-X22

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Special (Specify)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
  • Main Circuit Current Ratings: 30A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: No approvals required, refer to ticksheet
  • Safety Marks: No Safety Mark

BFC1PA-B03XBS-2000X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BFC1PA-B0ZXCS-0100X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Special (Specify)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 1A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFC1ZA-B02XAI-2500X-XXX

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: Special (Specify)
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable

BFC5ED-B02XBI-2500X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Clamp Terminal
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BFCCFD-B03XCS-1500X-X31

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Screw Terminal
  • Rated Voltage - Main Circuit: 80V Polarity Sensitive (0.6kA) MKI
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL 489A, UL508, IEC60934,VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BFCCPA-B02XCI-2500X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Screw Terminal
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BFQ1ED-B02XBS-0750X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 7.5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1ED-B02XBS-1500X-XXX

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable

BFQ1ED-B02XBS-2500X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1ED-B02XCS-0100X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 1A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1ED-B02XCS-0250X-XXX

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 2.5A
  • Relay Trip Coils: Not Applicable

BFQ1ED-B02XCS-0400X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 4A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1ED-B02XCS-1000X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1ED-B02XOP-0400X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Instantaneous
  • Main Circuit Current Ratings: 4A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1ED-B02XOP-0500X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Instantaneous
  • Main Circuit Current Ratings: 5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1ED-B12XCS-0400X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 4A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1ED-B12XCS-1000X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1ED-B13XBS-0050X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 0.5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1ED-D02XOX-2500D0-2412

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Relay Trip (Voltage Sensing)
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Switch
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: 24V DC
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1MM-B02XBD-0200X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
  • Main Circuit Current Ratings: 2A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1MM-B02XBD-0500X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
  • Main Circuit Current Ratings: 5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1PA-B02XAI-0400X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 4A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BFQ1PA-B02XAI-1000X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1PA-B02XAI-1200X-XXX

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 12A
  • Relay Trip Coils: Not Applicable

BFQ1PA-B02XAI-2500X-XXX

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable

BFQ1PA-B02XAS-0300X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 3A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1PA-B02XAS-1000X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1PA-B02XAS-1500X-XXX

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable

BFQ1PA-B02XAS-1600X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 16A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1PA-B02XAS-2000X-XXX

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable

BFQ1PA-B02XAS-3000X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 30A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Pages