info@cbibreakers.com  🗲 600 Eagleview Blvd, Exton, PA 19341  🗲  +1 610 524 9949

Screw: flush

BDHHFD-B0DXBS-3000X-X32

BDHHFD-B0DXBS-3000X-X32

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: S/Pole Rear Flush Screw
  • Rated Voltage - Main Circuit: 80V Polarity Sensitive (0.6kA) MKI
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I - O)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 30A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL 489A, UL508, IEC60934,VDE & CE
  • Safety Marks: No Safety Mark

BDHHFD-B0LXCS-3000X-X32

BDHHFD-B0LXCS-3000X-X32

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: S/Pole Rear Flush Screw
  • Rated Voltage - Main Circuit: 80V Polarity Sensitive (0.6kA) MKI
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 30A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL 489A, UL508, IEC60934,VDE & CE
  • Safety Marks: No Safety Mark

D-2AA4X1MBD-0100-BXX-XXXXXBDVAX1-C

D-2AA4X1MBD-0100-BXX-XXXXXBDVAX1-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 1 pole - Metric
  • Rated voltages - Main Circuit: AC & DC Multipole (80Vdc, 240/415Vac & 277/480Vac)
  • Time Delay : Medium Time Delay 50/60Hz/DC
  • Main Circuit Current: 1A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

D-2AA4X1MBD-0175-BXX-XXXXXBDVAX1-C

D-2AA4X1MBD-0175-BXX-XXXXXBDVAX1-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 1 pole - Metric
  • Rated voltages - Main Circuit: AC & DC Multipole (80Vdc, 240/415Vac & 277/480Vac)
  • Time Delay : Medium Time Delay 50/60Hz/DC
  • Main Circuit Current: 1.75
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

D-2AA4X2JBS-0200-BXX-XXXXXBDVAX2-X

D-2AA4X2JBS-0200-BXX-XXXXXBDVAX2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 2A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2AA4X2MBD-0200-BXX-XXXXXBDVAX1-X

D-2AA4X2MBD-0200-BXX-XXXXXBDVAX1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: AC & DC Multipole (80Vdc, 240/415Vac & 277/480Vac)
  • Time Delay : Medium Time Delay 50/60Hz/DC
  • Main Circuit Current: 2A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2AA4X2QAH-5000-BXX-XXXXXBDVAC1-C

D-2AA4X2QAH-5000-BXX-XXXXXBDVAC1-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac
  • Time Delay : Long Time Delay 50/60Hz
  • Main Circuit Current: 50A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

D-2AA4X2QBS-4000-BXX-XXXXXBCVAA1-X

D-2AA4X2QBS-4000-BXX-XXXXXBCVAA1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 40A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-SMALL
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2AA4X2SAH-1500-BXX-XXXXXWDVAC2-C

D-2AA4X2SAH-1500-BXX-XXXXXWDVAC2-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz
  • Main Circuit Current: 15A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2AA4X2SAH-2000-BXX-XXXXXWDVAC2-C

D-2AA4X2SAH-2000-BXX-XXXXXWDVAC2-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2AA4XAJBS-2000-BXX-XXXXXWDVAX2-C

D-2AA4XAJBS-2000-BXX-XXXXXWDVAX2-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2AA4XASAI-2500-BXX-XXXXXBDVAX2-X

D-2AA4XASAI-2500-BXX-XXXXXBDVAX2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Long Time Delay 50/60hz or DC (AS + Inertia Delay)
  • Main Circuit Current: 25A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2AA4XASAI-3000-BXX-XXXXXBDVAX2-X

D-2AA4XASAI-3000-BXX-XXXXXBDVAX2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Long Time Delay 50/60hz or DC (AS + Inertia Delay)
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2AA4XASAS-2000-BXX-XXXXXBDVAX2-X

D-2AA4XASAS-2000-BXX-XXXXXBDVAX2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2AA4XASBI-2000-BXX-XXXXX4DVAX2-X

D-2AA4XASBI-2000-BXX-XXXXX4DVAX2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC (BS + Inertia Delay)
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Blue handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2AA4XASBI-2000-BXX-XXXXXRDVAX2-X

D-2AA4XASBI-2000-BXX-XXXXXRDVAX2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC (BS + Inertia Delay)
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Red handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2AA4XBRBS-1000-BXX-XXXXXBDVAX1-X

D-2AA4XBRBS-1000-BXX-XXXXXBDVAX1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 10A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2AA4XBSAH-3000-BXX-XXXXXWDVAC2-X

D-2AA4XBSAH-3000-BXX-XXXXXWDVAC2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2AA4XBSAI-1500-BXX-XXXXXBDVAX2-X

D-2AA4XBSAI-1500-BXX-XXXXXBDVAX2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Long Time Delay 50/60hz or DC (AS + Inertia Delay)
  • Main Circuit Current: 15A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2AA4XBSAS-5000-BXX-XXXXXWDVAC2-C

D-2AA4XBSAS-5000-BXX-XXXXXWDVAC2-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2AA4XBSBS-3000-BXX-XXXXXWDVAC2-C

D-2AA4XBSBS-3000-BXX-XXXXXWDVAC2-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2AA4XCRAI-2000-BXX-XXXXXWDVAA1-X

D-2AA4XCRAI-2000-BXX-XXXXXWDVAA1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60hz or DC (AS + Inertia Delay)
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-SMALL
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2AA4XCRAS-1000-BXX-XXXXXBDVAB1-X

D-2AA4XCRAS-1000-BXX-XXXXXBDVAB1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 10A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2AA4XCRAS-1800-BXX-XXXXXBDVAX1-X

D-2AA4XCRAS-1800-BXX-XXXXXBDVAX1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 18A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2AA4XCRAS-4000-BXX-XXXXXBDVAB1-X

D-2AA4XCRAS-4000-BXX-XXXXXBDVAB1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 40A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2AW4X2SAH-1500-BXX-XXXXXXXXBC2-C

D-2AW4X2SAH-1500-BXX-XXXXXXXXBC2-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz
  • Main Circuit Current: 15A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2AW4X2SAH-2000-BXX-XXXXXXXXBC2-C

D-2AW4X2SAH-2000-BXX-XXXXXXXXBC2-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2AW4XBSAS-5000-BXX-XXXXXXXXBC2-C

D-2AW4XBSAS-5000-BXX-XXXXXXXXBC2-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2AW4XBSBS-3000-BXX-XXXXXXXXBC2-C

D-2AW4XBSBS-3000-BXX-XXXXXXXXBC2-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2AW4XCRAS-1000-BXX-XXXXXXXXBB1-X

D-2AW4XCRAS-1000-BXX-XXXXXXXXBB1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 10A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2AW4XCRAS-1800-BXX-XXXXXXXVAB1-X

D-2AW4XCRAS-1800-BXX-XXXXXXXVAB1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 18A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2AW4XCRAS-4000-BXX-XXXXXXXXAB1-X

D-2AW4XCRAS-4000-BXX-XXXXXXXXAB1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 40A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2S04X2JBS-3000-BXX-XXXXXXXXBC2-X

D-2S04X2JBS-3000-BXX-XXXXXXXXBC2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle - Raised Front Plate
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2S04X3JBS-2000-BXX-XXXXXXXXBC2-X

D-2S04X3JBS-2000-BXX-XXXXXXXXBC2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle - Raised Front Plate
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2S04X3JBS-3000-BXX-XXXXXXXXBC2-X

D-2S04X3JBS-3000-BXX-XXXXXXXXBC2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle - Raised Front Plate
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SH4X1NAS-4000-KXA-XXXXXBFVBX2-C

D-2SH4X1NAS-4000-KXA-XXXXXBFVBX2-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 1 pole - Metric
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 40A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB3-Gold Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 0.1A @ 250Vac & 0.1A @ 80Vdc and UL1054 0.1A @ 125/250Vac & 0.1A @ 30Vdc & 0.3A @ 60Vdc)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O and Amp rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2SH4X2SBS-1600-BXX-XXXXXWGVBA2-X

D-2SH4X2SBS-1600-BXX-XXXXXWGVBA2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 16A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: On - Off and Amp rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-SMALL
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SH4X2SBS-2500-BXX-XXXXXWGVBA2-X

D-2SH4X2SBS-2500-BXX-XXXXXWGVBA2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 25A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: On - Off and Amp rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-SMALL
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SH4XAJAS-3000-BXX-XXXXXWHVAX1-X

D-2SH4XAJAS-3000-BXX-XXXXXWHVAX1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SM4XANBS-1500-BXX-XXXXXWHVAX2-X

D-2SM4XANBS-1500-BXX-XXXXXWHVAX2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 15A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Pages

Looking for a distributor?

Visit our map-based Distributor search to find your closest supplier. Our carefully-selected distributors help you find the right circuit breaker for your needs

Find a distributor

 

Bulk & Custom Products

Are you an equipment manufacturer in telecoms or construction? If you are looking for custom configurations or bulk purchases, please contact our sales team.

Contact us

Protect your assets

Superior circuit breakers for equipment.