Stud

D-2SMMX3RBH-4000-BXX-XXXXXWHHB31-X

D-2SMMX3RBH-4000-BXX-XXXXXWHHB31-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz
  • Main Circuit Current: 40A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier and Terminal Cover-LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SMMX3RBH-7000-HXX-A5EXXGGHA31-X

D-2SMMX3RBH-7000-HXX-A5EXXGGHA31-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz
  • Main Circuit Current: 70A
  • Circuit Configuration: Dual Control - Relay Trip Construction (4 terminal)
  • Voltages & Coil Ratings (Dual Control): 220-240V AC 50/60Hz
  • Voltages & Coil Ratings (Dual Control): Stud Terminals (M5 / 10-32)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Green handle, White marking
  • Handle Marking: On - Off and Amp rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier and Terminal Cover-LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SMMXANAS-4000-BXX-XXXXXWHVBX1-X

D-2SMMXANAS-4000-BXX-XXXXXWHVBX1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 40A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SMMXANAS-5000-BXX-XXXXXWHVBX1-X

D-2SMMXANAS-5000-BXX-XXXXXWHVBX1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SMMXANAS-6000-BXX-XXXXXWHVBX1-X

D-2SMMXANAS-6000-BXX-XXXXXWHVBX1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 60A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SMMXANAS-8000-BXX-XXXXXWHVBX1-X

D-2SMMXANAS-8000-BXX-XXXXXWHVBX1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 80A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SMMXANAS-K100-BXX-XXXXXWHVBX1-X

D-2SMMXANAS-K100-BXX-XXXXXWHVBX1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 100A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SMMXANAS-K100-KXB-XXXXXRHVBX2-X

D-2SMMXANAS-K100-KXB-XXXXXRHVBX2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 100A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Red handle, White marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SMMXANBS-5000-KXB-XXXXXRHVBX2-X

D-2SMMXANBS-5000-KXB-XXXXXRHVBX2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Red handle, White marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SMMXANBS-8000-BXX-XXXXXWHH2X2-C

D-2SMMXANBS-8000-BXX-XXXXXWHH2X2-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 80A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2SMMXANCS-8000-BXX-XXXXXWH2AX2-X

D-2SMMXANCS-8000-BXX-XXXXXWH2AX2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Short Time Delay 50/60Hz or DC
  • Main Circuit Current: 80A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Right
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SMMXASAS-2000-BXX-XXXXXWH1BX2-X

D-2SMMXASAS-2000-BXX-XXXXXWH1BX2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical Reverse Mounting , Line @ Bottom
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SMMXBNBS-K110-KXB-XXXXXWHVAX3-X

D-2SMMXBNBS-K110-KXB-XXXXXWHVAX3-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 110A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: UL listed (UL489A), IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SMMXBRBS-5000-BXX-XXXXXWH1BC1-C

D-2SMMXBRBS-5000-BXX-XXXXXWH1BC1-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical Reverse Mounting , Line @ Bottom
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

D-2SMMXBRBS-7000-BXX-XXXXXWH1BC1-X

D-2SMMXBRBS-7000-BXX-XXXXXWH1BC1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 70A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical Reverse Mounting , Line @ Bottom
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SQAX1NCS-2600-HXX-B1CXXBZHAXZ-X

D-2SQAX1NCS-2600-HXX-B1CXXBZHAXZ-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 1 pole - Metric
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Short Time Delay 50/60Hz or DC
  • Main Circuit Current: 26A
  • Circuit Configuration: Dual Control - Relay Trip Construction (4 terminal)
  • Voltages & Coil Ratings (Dual Control): 24V DC
  • Voltages & Coil Ratings (Dual Control): Quick Connect Terminals (0.8mm x 6.35mm)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: Special specify
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: No approvals; Not for Commercial Sale without Prior arrangement with Manufacturer
  • Safety marks: Not Applicable

D-2SRMX1NBS-6000-BXX-XXXXXWIH2X2-C

D-2SRMX1NBS-6000-BXX-XXXXXWIH2X2-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Metric
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 60A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2SRMX1NBS-8000-BXX-XXXXXWIH2X2-C

D-2SRMX1NBS-8000-BXX-XXXXXWIH2X2-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Metric
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 80A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2SWAXBJBS-4000-BXX-XXXXXXXXBC1-X

D-2SWAXBJBS-4000-BXX-XXXXXXXXBC1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 40A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SWAXBJBS-6000-BXX-XXXXXXXXBC1-C

D-2SWAXBJBS-6000-BXX-XXXXXXXXBC1-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 60A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

D-2SWAXBRAS-3000-BXX-XXXXXXXXBX1-X

D-2SWAXBRAS-3000-BXX-XXXXXXXXBX1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SWAXBRAS-3500-BXX-XXXXXXXXBC1-X

D-2SWAXBRAS-3500-BXX-XXXXXXXXBC1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 35A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SWAXBRAS-5000-BXX-XXXXXXXXBC1-X

D-2SWAXBRAS-5000-BXX-XXXXXXXXBC1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SWAXCJCS-1500-BXX-XXXXXXXXBX2-X

D-2SWAXCJCS-1500-BXX-XXXXXXXXBX2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Short Time Delay 50/60Hz or DC
  • Main Circuit Current: 15A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SWAXCJCS-1500-KXA-XXXXXXXXBX2-X

D-2SWAXCJCS-1500-KXA-XXXXXXXXBX2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Short Time Delay 50/60Hz or DC
  • Main Circuit Current: 15A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB3-Gold Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 0.1A @ 250Vac & 0.1A @ 80Vdc and UL1054 0.1A @ 125/250Vac & 0.1A @ 30Vdc & 0.3A @ 60Vdc)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SWAXCRBS-5000-BXX-XXXXXXXXBA1-X

D-2SWAXCRBS-5000-BXX-XXXXXXXXBA1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-SMALL
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SWAXCRBS-5000-BXX-XXXXXXXXBC1-X

D-2SWAXCRBS-5000-BXX-XXXXXXXXBC1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SWAXCRBS-5000-GXX-A5EXXXXXBA1-X

D-2SWAXCRBS-5000-GXX-A5EXXXXXBA1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Dual Control - Shunt Trip Construction - 3rd Terminal Close to Load Side (3 Terminal)
  • Voltages & Coil Ratings (Dual Control): 220-240V AC 50/60Hz
  • Voltages & Coil Ratings (Dual Control): Stud Terminals (M5 / 10-32)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-SMALL
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SWMX3RBH-4000-BXX-XXXXXXXXB31-X

D-2SWMX3RBH-4000-BXX-XXXXXXXXB31-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz
  • Main Circuit Current: 40A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier and Terminal Cover-LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SWMX3RBH-4000-HXX-A5EXXXXXB31-X

D-2SWMX3RBH-4000-HXX-A5EXXXXXB31-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz
  • Main Circuit Current: 40A
  • Circuit Configuration: Dual Control - Relay Trip Construction (4 terminal)
  • Voltages & Coil Ratings (Dual Control): 220-240V AC 50/60Hz
  • Voltages & Coil Ratings (Dual Control): Stud Terminals (M5 / 10-32)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier and Terminal Cover-LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SWMX3RBH-7000-BXX-XXXXXXXXB31-X

D-2SWMX3RBH-7000-BXX-XXXXXXXXB31-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz
  • Main Circuit Current: 70A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier and Terminal Cover-LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SWMXBNBS-K110-HXM-B0DXXXXXBX3-X

D-2SWMXBNBS-K110-HXM-B0DXXXXXBX3-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 110A
  • Circuit Configuration: Dual Control - Relay Trip Construction (4 terminal)
  • Switches: Parallel Bridge Housing - For all Parallel Bridged Poles
  • Voltages & Coil Ratings (Dual Control): 12V DC
  • Voltages & Coil Ratings (Dual Control): Flying Leads (wire terminals)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: UL listed (UL489A), IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SWMXBRBS-5000-BXX-XXXXXXXXBC1-C

D-2SWMXBRBS-5000-BXX-XXXXXXXXBC1-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

D-2SWMXBRBS-7000-BXX-XXXXXXXXBC1-X

D-2SWMXBRBS-7000-BXX-XXXXXXXXBC1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 70A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-5AAAXDRAH-4000-BXX-XXXXXBDVAC1-X

D-5AAAXDRAH-4000-BXX-XXXXXBDVAC1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 4 pole – Imperial or RAU/LVR + 3 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz
  • Main Circuit Current: 40A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-5AAAXDRAH-4000-KXA-XXXXXBDVAC1-X

D-5AAAXDRAH-4000-KXA-XXXXXBDVAC1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 4 pole – Imperial or RAU/LVR + 3 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz
  • Main Circuit Current: 40A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB3-Gold Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 0.1A @ 250Vac & 0.1A @ 80Vdc and UL1054 0.1A @ 125/250Vac & 0.1A @ 30Vdc & 0.3A @ 60Vdc)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

SFM2-A3---------90AC2-AC3

Pages

Looking for a distributor?

Visit our map-based Distributor search to find your closest supplier. Our carefully-selected distributors help you find the right circuit breaker for your needs

Find a distributor

 

Bulk & Custom Products

Are you an equipment manufacturer in telecoms or construction? If you are looking for custom configurations or bulk purchases, please contact our sales team.

Contact us

Protect your assets

Superior circuit breakers for equipment.