DD-Frame

DD-Frame

Dimensional Drawings: 

DD-Frame: 0,5-400A for AC and DC applications.

The DD-Frame is a compact yet powerful circuit breaker. The hydraulic-magnetic technology is unaffected by ambient temperature, making it suitable for telecom and datacom equipment like power supplies, lighting control, inverters and power distribution.  It withstands harsh environmental conditions in military, railway and renewable energy solutions. The DD-Frame is also available as a switch. Optional auxiliary switch and trip alarm.

Due to it's robust frame and ability to withstand harsh environments, the DD Frame breaker is used in military and railway applications, and in renewable energy solutions for protection of combiner boxes and battery storage.

Configurations

  • 1 to 6 poles
  • AC and DC configurations
  • Rating 0.1A to 100 A AC and 400 A DC
  • Toggle, rocker, flush rocker handle options
  • Metric and imperial stud terminals, plug in (bullet), screw and clamp
  • Optional auxiliary switch and trip alarm
  • Customer specific configurations for DIN rail mount and other options.
  • Precision tripping, with a choice of time delay characteristics

Approvals

  • UL recognized: UL1077, UL1500 and UL 508
  • UL Listed: UL489 and UL489A
  • CE Certified, VDE, cURus, CSA, EAC and CCC.

Remote Actuator Units (RAU)

For applications including energy storage, battery management and telecom UPS systems, a CBI DD-frame can be fitted in remote areas as well as in places where it’s not necessarily easy to access the circuit breaker in the equipment but still have full control in terms of operating the MCB.

Using the CBi RAU together with a CBi DD-frame in your application enables you to take your equipment to the next level in terms of remote accessibility, as well as giving the possibility to dramatically reduce maintenance cost and system down time if a non-fatal fault tripping occurs.

D-2SH4XAJAS-3000-BXX-XXXXXWHVAX1-X

D-2SH4XAJAS-3000-BXX-XXXXXWHVAX1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SH5XASBS-0500-BXX-XXXXXWHVAX2-X

D-2SH5XASBS-0500-BXX-XXXXXWHVAX2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle
  • Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 5A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SH5XBSAS-2500-BXX-XXXXXBHVBB2-C

D-2SH5XBSAS-2500-BXX-XXXXXBHVBB2-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle
  • Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 25A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2SH5XCJBS-3000-BXX-XXXXXWHVAC2-X

D-2SH5XCJBS-3000-BXX-XXXXXWHVAC2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle
  • Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SH5XCRBS-3000-BXX-XXXXXBHVAC1-C

D-2SH5XCRBS-3000-BXX-XXXXXBHVAC1-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle
  • Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

D-2SH5XCRBS-3000-BXX-XXXXXXXXBC1-C

D-2SH5XCRBS-3000-BXX-XXXXXXXXBC1-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle
  • Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

D-2SHAXBJBS-4000-BXX-XXXXXRHHAC1-X

D-2SHAXBJBS-4000-BXX-XXXXXRHHAC1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 40A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Red handle, White marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SHAXBJBS-6000-BXX-XXXXXRHHAC1-C

D-2SHAXBJBS-6000-BXX-XXXXXRHHAC1-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 60A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Red handle, White marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

D-2SHAXCRBS-5000-BXX-XXXXXWH1BA1-X

D-2SHAXCRBS-5000-BXX-XXXXXWH1BA1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical Reverse Mounting , Line @ Bottom
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-SMALL
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SHMXANBS-8000-KXB-XXXXXRHVAX1-X

D-2SHMXANBS-8000-KXB-XXXXXRHVAX1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 80A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Red handle, White marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SM3X1NCS-K100-KXB-XXXXXWHHBX2-X

D-2SM3X1NCS-K100-KXB-XXXXXWHHBX2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Push-in Bullet (dia 7.8mm x 16.4mm)
  • No of Poles: 1 pole - Metric
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Short Time Delay 50/60Hz or DC
  • Main Circuit Current: 100A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SM3XAJCS-1500-MXA-XXXXXWH1AX2-X

D-2SM3XAJCS-1500-MXA-XXXXXWH1AX2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Push-in Bullet (dia 7.8mm x 16.4mm)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Short Time Delay 50/60Hz or DC
  • Main Circuit Current: 15A
  • Circuit Configuration: Trip Alarm, but no Mid Trip (Reversed Function - Latch Type)
  • Switches: DB3-Gold Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 0.1A @ 250Vac & 0.1A @ 80Vdc and UL1054 0.1A @ 125/250Vac & 0.1A @ 30Vdc & 0.3A @ 60Vdc)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical Reverse Mounting , Line @ Bottom
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SM3XBJCS-2500-MXA-XXXXXWH1AC2-X

D-2SM3XBJCS-2500-MXA-XXXXXWH1AC2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Push-in Bullet (dia 7.8mm x 16.4mm)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Short Time Delay 50/60Hz or DC
  • Main Circuit Current: 25A
  • Circuit Configuration: Trip Alarm, but no Mid Trip (Reversed Function - Latch Type)
  • Switches: DB3-Gold Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 0.1A @ 250Vac & 0.1A @ 80Vdc and UL1054 0.1A @ 125/250Vac & 0.1A @ 30Vdc & 0.3A @ 60Vdc)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical Reverse Mounting , Line @ Bottom
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SM3XCJCS-2000-MXA-XXXXXWH1AC2-X

D-2SM3XCJCS-2000-MXA-XXXXXWH1AC2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Push-in Bullet (dia 7.8mm x 16.4mm)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Short Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Trip Alarm, but no Mid Trip (Reversed Function - Latch Type)
  • Switches: DB3-Gold Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 0.1A @ 250Vac & 0.1A @ 80Vdc and UL1054 0.1A @ 125/250Vac & 0.1A @ 30Vdc & 0.3A @ 60Vdc)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical Reverse Mounting , Line @ Bottom
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SM4XANBS-1500-BXX-XXXXXWHVAX2-X

D-2SM4XANBS-1500-BXX-XXXXXWHVAX2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 15A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SM4XBSBS-2000-BXX-XXXXXWHHAC2-X

D-2SM4XBSBS-2000-BXX-XXXXXWHHAC2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SM5XAJBS-2000-BXX-XXXXXWHVBX2-C

D-2SM5XAJBS-2000-BXX-XXXXXWHVBX2-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2SM5XBJBS-2000-BXX-XXXXXRHVAC1-X

D-2SM5XBJBS-2000-BXX-XXXXXRHVAC1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Red handle, White marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SMAXAKAS-5000-KXB-XXXXXRHVBX1-X

D-2SMAXAKAS-5000-KXB-XXXXXRHVBX1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240Vac; 277Vac (Single Pole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Red handle, White marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SMAXASBS-5000-BXX-XXXXXWHVAX2-X

D-2SMAXASBS-5000-BXX-XXXXXWHVAX2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SMAXBRAS-3000-KXB-XXXXXRHVBX1-X

D-2SMAXBRAS-3000-KXB-XXXXXRHVBX1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Red handle, White marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SMAXBRAS-3500-KXB-XXXXXRHVBC1-X

D-2SMAXBRAS-3500-KXB-XXXXXRHVBC1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 35A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Red handle, White marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SMAXBRAS-5000-KXB-XXXXXRHVBC1-X

D-2SMAXBRAS-5000-KXB-XXXXXRHVBC1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Red handle, White marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SMAXCJCS-1500-BXX-XXXXXWH1AX2-X

D-2SMAXCJCS-1500-BXX-XXXXXWH1AX2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Short Time Delay 50/60Hz or DC
  • Main Circuit Current: 15A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical Reverse Mounting , Line @ Bottom
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SMAXCRBS-5000-BXX-XXXXXRHVAC1-X

D-2SMAXCRBS-5000-BXX-XXXXXRHVAC1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Red handle, White marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SMMX1NBS-8000-BXX-XXXXXWHVAX2-X

D-2SMMX1NBS-8000-BXX-XXXXXWHVAX2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Metric
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 80A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SMMX1NBS-8000-KXB-XXXXXWHVAX2-X

D-2SMMX1NBS-8000-KXB-XXXXXWHVAX2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Metric
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 80A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SMMX1NCS-8000-KXB-XXXXXWHHBX2-C

D-2SMMX1NCS-8000-KXB-XXXXXWHHBX2-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Metric
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Short Time Delay 50/60Hz or DC
  • Main Circuit Current: 80A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2SMMX3RBH-4000-BXX-XXXXXWHHB31-X

D-2SMMX3RBH-4000-BXX-XXXXXWHHB31-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz
  • Main Circuit Current: 40A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier and Terminal Cover-LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SMMX3RBH-7000-HXX-A5EXXGGHA31-X

D-2SMMX3RBH-7000-HXX-A5EXXGGHA31-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz
  • Main Circuit Current: 70A
  • Circuit Configuration: Dual Control - Relay Trip Construction (4 terminal)
  • Voltages & Coil Ratings (Dual Control): 220-240V AC 50/60Hz
  • Voltages & Coil Ratings (Dual Control): Stud Terminals (M5 / 10-32)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Green handle, White marking
  • Handle Marking: On - Off and Amp rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier and Terminal Cover-LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SMMXANAS-4000-BXX-XXXXXWHVBX1-X

D-2SMMXANAS-4000-BXX-XXXXXWHVBX1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 40A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SMMXANAS-5000-BXX-XXXXXWHVBX1-X

D-2SMMXANAS-5000-BXX-XXXXXWHVBX1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SMMXANAS-6000-BXX-XXXXXWHVBX1-X

D-2SMMXANAS-6000-BXX-XXXXXWHVBX1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 60A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SMMXANAS-8000-BXX-XXXXXWHVBX1-X

D-2SMMXANAS-8000-BXX-XXXXXWHVBX1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 80A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SMMXANAS-K100-BXX-XXXXXWHVBX1-X

D-2SMMXANAS-K100-BXX-XXXXXWHVBX1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 100A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SMMXANAS-K100-KXB-XXXXXRHVBX2-X

D-2SMMXANAS-K100-KXB-XXXXXRHVBX2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 100A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Red handle, White marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SMMXANBS-5000-KXB-XXXXXRHVBX2-X

D-2SMMXANBS-5000-KXB-XXXXXRHVBX2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Red handle, White marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SMMXANBS-8000-BXX-XXXXXWHH2X2-C

D-2SMMXANBS-8000-BXX-XXXXXWHH2X2-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 80A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2SMMXANCS-8000-BXX-XXXXXWH2AX2-X

D-2SMMXANCS-8000-BXX-XXXXXWH2AX2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Short Time Delay 50/60Hz or DC
  • Main Circuit Current: 80A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Right
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SMMXASAS-2000-BXX-XXXXXWH1BX2-X

D-2SMMXASAS-2000-BXX-XXXXXWH1BX2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical Reverse Mounting , Line @ Bottom
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Pages

Looking for a distributor?

Visit our map-based Distributor search to find your closest supplier. Our carefully-selected distributors help you find the right circuit breaker for your needs

Find a distributor

 

Bulk & Custom Products

Are you an equipment manufacturer in telecoms or construction? If you are looking for custom configurations or bulk purchases, please contact our sales team.

Contact us

Protect your assets

Superior circuit breakers for equipment.