Keyword Search
Add a space between keywords.
Displaying 1 - 50 of 2252YFK---2-(13)-M-30A-ACM-----
Product Type: Circuit Breaker for Equipment (CBE)
Frame: Y-Frame (YA, YB, YF)
No of Poles: 2
Current Rating: 30 A
Frequency: AC/DC
Mounting: DIN Rail / Surface
Termination: Box terminal/lugs
BAA1MM-B03XAD-0800X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Square Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:65V DC / 240V AC MKII
- Frequency:AC / DC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:Black (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay (Dual Rated)
- Main Circuit Current Ratings:8A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BAA1MM-B03XAD-1000X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Square Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:65V DC / 240V AC MKII
- Frequency:AC / DC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:Black (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay (Dual Rated)
- Main Circuit Current Ratings:10A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BAA1MM-B03XAW-0200X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Square Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:65V DC / 240V AC MKII
- Frequency:AC / DC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:Black (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay (AD + Inertia Delay)
- Main Circuit Current Ratings:2A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BAA1MM-B03XAW-0300X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Square Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:65V DC / 240V AC MKII
- Frequency:AC / DC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:Black (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay (AD + Inertia Delay)
- Main Circuit Current Ratings:3A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BAA1MM-B03XAW-0400X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Square Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:65V DC / 240V AC MKII
- Frequency:AC / DC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:Black (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay (AD + Inertia Delay)
- Main Circuit Current Ratings:4A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BAA1MM-B03XAW-0800X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Square Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:65V DC / 240V AC MKII
- Frequency:AC / DC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:Black (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay (AD + Inertia Delay)
- Main Circuit Current Ratings:8A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BAA1MM-B03XAW-1000X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Square Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:65V DC / 240V AC MKII
- Frequency:AC / DC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:Black (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay (AD + Inertia Delay)
- Main Circuit Current Ratings:10A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BAABED-B03XAS-2000X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Square Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Double Pole Unit with 90 Deg. Bent Terminal
- Rated Voltage - Main Circuit:65V DC (0.5kA) MKII
- Frequency:DC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:Black (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay
- Main Circuit Current Ratings:20A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BAACFD-B03XAS-3000X-X32
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Square Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Screw Terminal
- Rated Voltage - Main Circuit:80V Polarity Sensitive (0.6kA) MKI
- Frequency:DC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:Black (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay
- Main Circuit Current Ratings:30A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL 489A, UL508, IEC60934,VDE & CE
- Safety Marks: No Safety Mark
BAACPA-B03XAI-0100X-XXX
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Square Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Screw Terminal
- Rated Voltage - Main Circuit:240V (1kA) MKII
- Frequency:AC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:Black (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay (AS + Inertia Delay)
- Main Circuit Current Ratings:1A
- Relay Trip Coils:Not Applicable
BAACPA-B03XAI-0200X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Square Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Screw Terminal
- Rated Voltage - Main Circuit:240V (1kA) MKII
- Frequency:AC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:Black (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay (AS + Inertia Delay)
- Main Circuit Current Ratings:2A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BAACPA-B03XAI-0300X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Square Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Screw Terminal
- Rated Voltage - Main Circuit:240V (1kA) MKII
- Frequency:AC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:Black (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay (AS + Inertia Delay)
- Main Circuit Current Ratings:3A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BAACPA-B03XBS-3000X-X22
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Square Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Screw Terminal
- Rated Voltage - Main Circuit:240V (1kA) MKII
- Frequency:AC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:Black (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Medium Time Delay
- Main Circuit Current Ratings:30A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:No approvals required, refer to ticksheet
- Safety Marks: No Safety Mark
BAADPA-B03XBS-0100X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Square Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Double Pole Unit, Screw Terminal
- Rated Voltage - Main Circuit:240V (1kA) MKII
- Frequency:AC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:Black (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Medium Time Delay
- Main Circuit Current Ratings:1A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BAC1FD-B03XBS-3000X-X32
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Square Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 80V Polarity Sensitive (0.6kA) MKI
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 30A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL 489A, UL508, IEC60934,VDE & CE
- Safety Marks: No Safety Mark
BAC1MM-B02XBW-0500X-XXX
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Square Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BD + Inertia Delay)
- Main Circuit Current Ratings: 5A
- Relay Trip Coils: Not Applicable
BAC1MM-B02XBW-1000X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Square Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BD + Inertia Delay)
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BAC1MM-B02XBW-1500X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Square Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BD + Inertia Delay)
- Main Circuit Current Ratings: 15A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BAC1MM-B02XBW-2000X-XXX
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Square Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BD + Inertia Delay)
- Main Circuit Current Ratings: 20A
- Relay Trip Coils: Not Applicable
BAC1PA-B03XBI-0300X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Square Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
- Main Circuit Current Ratings: 3A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BAC1PA-B03XBI-0700X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Square Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
- Main Circuit Current Ratings: 7A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BAC1PA-B03XBI-1000X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Square Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BAC1PA-B03XBS-0300X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Square Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 3A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BAC1PA-B03XBS-0700X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Square Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 7A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BAC1PA-B03XBS-1000X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Square Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BAC1PA-B12XAS-3000X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Square Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
- Main Circuit Current Ratings: 30A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BAC1ZA-B02XAI-2500X-XXX
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Square Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: Special (Specify)
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
- Main Circuit Current Ratings: 25A
- Relay Trip Coils: Not Applicable
BAC1ZA-B02XBS-2500X-XXX
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Square Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: Special (Specify)
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 25A
- Relay Trip Coils: Not Applicable
BAC2MM-B03XCW-1000X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Square Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CD + Inertia Delay)
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BAC2PA-B03XBS-0150X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Square Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 1.5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BAC2PA-B03XBS-500MX-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Square Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 500mA
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BAC5ED-B03XOP-2000X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Square Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Instantaneous
- Main Circuit Current Ratings: 20A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BACBPA-B03XBS-0200X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Square Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Double Pole Unit with 90 Deg. Bent Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 2A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BAR1ED-B03XAS-2000X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Square Handle
- Mounting: Clip In Mounting
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
- Main Circuit Current Ratings: 20A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBA1FD-B03XAS-1500X-X32
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Paddle Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:80V Polarity Sensitive (0.6kA) MKI
- Frequency:DC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:Black (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay
- Main Circuit Current Ratings:15A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL 489A, UL508, IEC60934,VDE & CE
- Safety Marks: No Safety Mark
BBA1MM-B02XBD-0500X-XXX
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Paddle Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:65V DC / 240V AC MKII
- Frequency:AC / DC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:White (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Medium Time Delay (Dual Rated)
- Main Circuit Current Ratings:5A
- Relay Trip Coils:Not Applicable
BBA1MM-B02XBD-1000X-XXX
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Paddle Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:65V DC / 240V AC MKII
- Frequency:AC / DC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:White (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Medium Time Delay (Dual Rated)
- Main Circuit Current Ratings:10A
- Relay Trip Coils:Not Applicable
BBA1MM-B02XBD-1500X-XXX
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Paddle Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:65V DC / 240V AC MKII
- Frequency:AC / DC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:White (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Medium Time Delay (Dual Rated)
- Main Circuit Current Ratings:15A
- Relay Trip Coils:Not Applicable
BBA1MM-B02XBD-2000X-XXX
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Paddle Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:65V DC / 240V AC MKII
- Frequency:AC / DC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:White (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Medium Time Delay (Dual Rated)
- Main Circuit Current Ratings:20A
- Relay Trip Coils:Not Applicable
BBA1PA-B01XCI-130MX-XXX
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Paddle Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:240V (1kA) MKII
- Frequency:AC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:Green (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings:130mA
- Relay Trip Coils:Not Applicable
BBA1PA-B02XCS-0500X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Paddle Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:240V (1kA) MKII
- Frequency:AC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:White (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Short Time Delay
- Main Circuit Current Ratings:5A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBA1PA-B02XCS-1000X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Paddle Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:240V (1kA) MKII
- Frequency:AC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:White (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Short Time Delay
- Main Circuit Current Ratings:10A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBA1PA-B02XCS-100MX-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Paddle Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:240V (1kA) MKII
- Frequency:AC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:White (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Short Time Delay
- Main Circuit Current Ratings:100mA
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBA1PA-B02XCS-1700X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Paddle Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:240V (1kA) MKII
- Frequency:AC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:White (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Short Time Delay
- Main Circuit Current Ratings:17A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)