info@cbibreakers.com  🗲 salesasia@cbi-electric.com (Asia)
600 Eagleview Blvd, Exton, PA 19341  🗲  +1 610 524 9949

No of Poles

Current Rating

Voltage Rating AC

Voltage Rating DC

Frequency

Circuit Type

Mounting

Actuator Handle

Termination

Trip Characteristics

Filter by frame:

CBi Search: A-Z List

This searchable catalog shows pre-configured, popular products already in our system.

For custom configurations, please contact us. We recommend that you identify products closest to your requirements, and then order a sample noting your custom configuration. Our representative will contact you.

HTabGroup

A - Z (Full Detail)
Displaying 801 - 810 of 2252

If no results are displayed, please adjust your choices on the left. The first selections might be slow, as there are thousands of records to load! As you select, each remaining search parameter will recalculate.

C-B2ACXBSAI-2000-BXX-XXXXXBDVBC2-X

Vertical Tabs

Detail
No of Poles: 
2
Current Rating: 
16 - 30 A
Frequency: 
AC only
Voltage Rating AC: 
120 / 240V AC
Mounting: 
Panel mount: Imperial
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Slow
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame: C-Frame
  • Type: C-Frame IV
  • Mounting: Front mount round aperture, fleet
  • Handle: Standard (Toggle) handle
  • Termination: Quick Connect Terminal (0.8mm x 6.35mm) Max 30A
  • Number of Poles: 2 pole imperial
  • Rated Voltage & Frequency - Main Circuit: 120/240V 50/60Hz
  • Time Delay Characteristics (Curve Details); Pulse Tolerance at 10mS: Long delay & Inertia Wheel
  • Main Circuit Current: 20A
  • Circuit Configuration (Circuit Breaker's Internal Construction): Circuit Breaker (Series Trip Current Sensing)
  • Handle colour and marking details: Black/White Marking
  • Orientation of print: I - O and ON - OFF
  • Handle marking Orientation: Vertical (V) (Standard Mounting , Line @ Top)
  • Front plate: Black front plate no marking
  • Inter-phase barier and terminal cover: Z Inter-phase barrier
  • Approvals: UL489,IEC/EN 60934, CE
  • Safety marks: Not Applicable
Order Sample

C-BCA21ASAS-0500-KXB-XXXXXBHVAX2-C

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
0.1 - 5 A
Frequency: 
AC only
Voltage Rating AC: 
120 / 240V AC
Mounting: 
Panel mount: Imperial
Termination: 
Screw: bus
Trip Characteristics
Trip Characteristics: 
Slow
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame: C-Frame
  • Type: C-Frame IV
  • Mounting: Front mount round aperture, dome
  • Handle: Standard (Toggle) handle
  • Termination: Screw terminal,Bus connected (M4 or 8-32)
  • Number of Poles: 1 pole imperial
  • Rated Voltage & Frequency - Main Circuit: 120/240V 50/60Hz
  • Time Delay Characteristics (Curve Details); Pulse Tolerance at 10mS: Long delay
  • Main Circuit Current: 5A
  • Circuit Configuration (Circuit Breaker's Internal Construction): Series Trip, with Auxiliary Switch
  • Handle colour and marking details: Black/White Marking
  • Orientation of print: I - O and ON - OFF and ampere rating
  • Handle marking Orientation: Vertical (V) (Standard Mounting , Line @ Top)
  • Front plate: Black front plate std marking
  • Inter-phase barier and terminal cover: Not applicable
  • Approvals: UL489,IEC/EN 60934, CE
  • Safety marks: CCC / CRCC
Order Sample

C-BCA21ASAS-1000-KXB-XXXXXBHVAX2-C

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
6 - 15 A
Frequency: 
AC only
Voltage Rating AC: 
120 / 240V AC
Mounting: 
Panel mount: Imperial
Termination: 
Screw: bus
Trip Characteristics
Trip Characteristics: 
Slow
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame: C-Frame
  • Type: C-Frame IV
  • Mounting: Front mount round aperture, dome
  • Handle: Standard (Toggle) handle
  • Termination: Screw terminal,Bus connected (M4 or 8-32)
  • Number of Poles: 1 pole imperial
  • Rated Voltage & Frequency - Main Circuit: 120/240V 50/60Hz
  • Time Delay Characteristics (Curve Details); Pulse Tolerance at 10mS: Long delay
  • Main Circuit Current: 10A
  • Circuit Configuration (Circuit Breaker's Internal Construction): Series Trip, with Auxiliary Switch
  • Handle colour and marking details: Black/White Marking
  • Orientation of print: I - O and ON - OFF and ampere rating
  • Handle marking Orientation: Vertical (V) (Standard Mounting , Line @ Top)
  • Front plate: Black front plate std marking
  • Inter-phase barier and terminal cover: Not applicable
  • Approvals: UL489,IEC/EN 60934, CE
  • Safety marks: CCC / CRCC
Order Sample

C-BCA21ASAS-1500-KXB-XXXXXBHVAX2-C

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
6 - 15 A
Frequency: 
AC only
Voltage Rating AC: 
120 / 240V AC
Mounting: 
Panel mount: Imperial
Termination: 
Screw: bus
Trip Characteristics
Trip Characteristics: 
Slow
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame: C-Frame
  • Type: C-Frame IV
  • Mounting: Front mount round aperture, dome
  • Handle: Standard (Toggle) handle
  • Termination: Screw terminal,Bus connected (M4 or 8-32)
  • Number of Poles: 1 pole imperial
  • Rated Voltage & Frequency - Main Circuit: 120/240V 50/60Hz
  • Time Delay Characteristics (Curve Details); Pulse Tolerance at 10mS: Long delay
  • Main Circuit Current: 15A
  • Circuit Configuration (Circuit Breaker's Internal Construction): Series Trip, with Auxiliary Switch
  • Handle colour and marking details: Black/White Marking
  • Orientation of print: I - O and ON - OFF and ampere rating
  • Handle marking Orientation: Vertical (V) (Standard Mounting , Line @ Top)
  • Front plate: Black front plate std marking
  • Inter-phase barier and terminal cover: Not applicable
  • Approvals: UL489,IEC/EN 60934, CE
  • Safety marks: CCC / CRCC
Order Sample

C-BCA21ASAS-2000-KXB-XXXXXBHVAX2-C

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
16 - 30 A
Frequency: 
AC only
Voltage Rating AC: 
120 / 240V AC
Mounting: 
Panel mount: Imperial
Termination: 
Screw: bus
Trip Characteristics
Trip Characteristics: 
Slow
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame: C-Frame
  • Type: C-Frame IV
  • Mounting: Front mount round aperture, dome
  • Handle: Standard (Toggle) handle
  • Termination: Screw terminal,Bus connected (M4 or 8-32)
  • Number of Poles: 1 pole imperial
  • Rated Voltage & Frequency - Main Circuit: 120/240V 50/60Hz
  • Time Delay Characteristics (Curve Details); Pulse Tolerance at 10mS: Long delay
  • Main Circuit Current: 20A
  • Circuit Configuration (Circuit Breaker's Internal Construction): Series Trip, with Auxiliary Switch
  • Handle colour and marking details: Black/White Marking
  • Orientation of print: I - O and ON - OFF and ampere rating
  • Handle marking Orientation: Vertical (V) (Standard Mounting , Line @ Top)
  • Front plate: Black front plate std marking
  • Inter-phase barier and terminal cover: Not applicable
  • Approvals: UL489,IEC/EN 60934, CE
  • Safety marks: CCC / CRCC
Order Sample

C-BCA21BSAS-1600-BXX-XXXXXBHVAC2-C

Vertical Tabs

Detail
No of Poles: 
2
Current Rating: 
16 - 30 A
Frequency: 
AC only
Voltage Rating AC: 
120 / 240V AC
Mounting: 
Panel mount: Imperial
Termination: 
Screw: bus
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Slow
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame: C-Frame
  • Type: C-Frame IV
  • Mounting: Front mount round aperture, dome
  • Handle: Standard (Toggle) handle
  • Termination: Screw terminal,Bus connected (M4 or 8-32)
  • Number of Poles: 2 pole imperial
  • Rated Voltage & Frequency - Main Circuit: 120/240V 50/60Hz
  • Time Delay Characteristics (Curve Details); Pulse Tolerance at 10mS: Long delay
  • Main Circuit Current: 16A
  • Circuit Configuration (Circuit Breaker's Internal Construction): Circuit Breaker (Series Trip Current Sensing)
  • Handle colour and marking details: Black/White Marking
  • Orientation of print: I - O and ON - OFF and ampere rating
  • Handle marking Orientation: Vertical (V) (Standard Mounting , Line @ Top)
  • Front plate: Black front plate std marking
  • Inter-phase barier and terminal cover: Z Inter-phase barrier
  • Approvals: UL489,IEC/EN 60934, CE
  • Safety marks: CCC / CRCC
Order Sample

C-BCA21BSAS-1600-KXB-XXXXXBHVAC2-C

Vertical Tabs

Detail
No of Poles: 
2
Current Rating: 
16 - 30 A
Frequency: 
AC only
Voltage Rating AC: 
120 / 240V AC
Mounting: 
Panel mount: Imperial
Termination: 
Screw: bus
Trip Characteristics
Trip Characteristics: 
Slow
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame: C-Frame
  • Type: C-Frame IV
  • Mounting: Front mount round aperture, dome
  • Handle: Standard (Toggle) handle
  • Termination: Screw terminal,Bus connected (M4 or 8-32)
  • Number of Poles: 2 pole imperial
  • Rated Voltage & Frequency - Main Circuit: 120/240V 50/60Hz
  • Time Delay Characteristics (Curve Details); Pulse Tolerance at 10mS: Long delay
  • Main Circuit Current: 16A
  • Circuit Configuration (Circuit Breaker's Internal Construction): Series Trip, with Auxiliary Switch
  • Handle colour and marking details: Black/White Marking
  • Orientation of print: I - O and ON - OFF and ampere rating
  • Handle marking Orientation: Vertical (V) (Standard Mounting , Line @ Top)
  • Front plate: Black front plate std marking
  • Inter-phase barier and terminal cover: Z Inter-phase barrier
  • Approvals: UL489,IEC/EN 60934, CE
  • Safety marks: CCC / CRCC
Order Sample

C-BCA21BSAS-2000-BXX-XXXXXBHVBC2-C

Vertical Tabs

Detail
No of Poles: 
2
Current Rating: 
16 - 30 A
Frequency: 
AC only
Voltage Rating AC: 
120 / 240V AC
Mounting: 
Panel mount: Imperial
Termination: 
Screw: bus
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Slow
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame: C-Frame
  • Type: C-Frame IV
  • Mounting: Front mount round aperture, dome
  • Handle: Standard (Toggle) handle
  • Termination: Screw terminal,Bus connected (M4 or 8-32)
  • Number of Poles: 2 pole imperial
  • Rated Voltage & Frequency - Main Circuit: 120/240V 50/60Hz
  • Time Delay Characteristics (Curve Details); Pulse Tolerance at 10mS: Long delay
  • Main Circuit Current: 20A
  • Circuit Configuration (Circuit Breaker's Internal Construction): Circuit Breaker (Series Trip Current Sensing)
  • Handle colour and marking details: Black/White Marking
  • Orientation of print: I - O and ON - OFF and ampere rating
  • Handle marking Orientation: Vertical (V) (Standard Mounting , Line @ Top)
  • Front plate: Black front plate no marking
  • Inter-phase barier and terminal cover: Z Inter-phase barrier
  • Approvals: UL489,IEC/EN 60934, CE
  • Safety marks: CCC / CRCC
Order Sample

C-BCA21BSAS-2000-KXB-XXXXXBHVBC2-C

Vertical Tabs

Detail
No of Poles: 
2
Current Rating: 
16 - 30 A
Frequency: 
AC only
Voltage Rating AC: 
120 / 240V AC
Mounting: 
Panel mount: Imperial
Termination: 
Screw: bus
Trip Characteristics
Trip Characteristics: 
Slow
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame: C-Frame
  • Type: C-Frame IV
  • Mounting: Front mount round aperture, dome
  • Handle: Standard (Toggle) handle
  • Termination: Screw terminal,Bus connected (M4 or 8-32)
  • Number of Poles: 2 pole imperial
  • Rated Voltage & Frequency - Main Circuit: 120/240V 50/60Hz
  • Time Delay Characteristics (Curve Details); Pulse Tolerance at 10mS: Long delay
  • Main Circuit Current: 20A
  • Circuit Configuration (Circuit Breaker's Internal Construction): Series Trip, with Auxiliary Switch
  • Handle colour and marking details: Black/White Marking
  • Orientation of print: I - O and ON - OFF and ampere rating
  • Handle marking Orientation: Vertical (V) (Standard Mounting , Line @ Top)
  • Front plate: Black front plate no marking
  • Inter-phase barier and terminal cover: Z Inter-phase barrier
  • Approvals: UL489,IEC/EN 60934, CE
  • Safety marks: CCC / CRCC
Order Sample

C-BCA22ANAS-5000-BXX-XXXXXBHVBX3-C

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
31 - 50 A
Frequency: 
DC only
Voltage Rating DC: 
61 - 80V DC
Mounting: 
Panel mount: Imperial
Termination: 
Screw: bus
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Slow
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame: C-Frame
  • Type: C-Frame IV
  • Mounting: Front mount round aperture, dome
  • Handle: Standard (Toggle) handle
  • Termination: Screw terminal,Bus connected (M5 or 10-32) Max 50A
  • Number of Poles: 1 pole imperial
  • Rated Voltage & Frequency - Main Circuit: 80V DC
  • Time Delay Characteristics (Curve Details); Pulse Tolerance at 10mS: Long delay
  • Main Circuit Current: 50A
  • Circuit Configuration (Circuit Breaker's Internal Construction): Circuit Breaker (Series Trip Current Sensing)
  • Handle colour and marking details: Black/White Marking
  • Orientation of print: I - O and ON - OFF and ampere rating
  • Handle marking Orientation: Vertical (V) (Standard Mounting , Line @ Top)
  • Front plate: Black front plate no marking
  • Inter-phase barier and terminal cover: Not applicable
  • Approvals: UL489A, IEC/EN 60934, CE
  • Safety marks: CCC / CRCC
Order Sample

Pages

Accordion View
List View
Keyword Search