The B Series is a very compact yet robust circuit breaker for applications with space constraints. It offers a wide range of handles, and is used in applications like telecoms, lighting, railways signalling and solar power. It is available in single and double pole configurations for both AC and DC applications. There is a choice for time delay characteristics and auxiliary switch options.

Options

  • Single or double pole
  • AC, DC or dual frequency
  • Relay or Series Trip with a range of delays, with or without auxiliary switch
  • 0.1 to 30A current
  • 240V AC and up to 125V DC
  • Available in Metric or Imperial panel mounts, or Snap-in Mounts
  • Screw, Clamp or Quick Connect terminations
  • CBE Catalog Search

BEG1MM-B0Z3BD-2500X-X12

BEG1MM-B0Z3BD-2500X-X12

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Special (Specify)
  • Voltages for Illuminated Rocker Units: 4 - 8V DC Lead Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BEG1MM-B0ZCBD-2500X-X12

BEG1MM-B0ZCBD-2500X-X12

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Special (Specify)
  • Voltages for Illuminated Rocker Units: 4 - 8V DC Terminal Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BEG1PA-B0A1BS-2000X-X11

BEG1PA-B0A1BS-2000X-X11

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Green (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: 100 - 110V AC Lead Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BEG2PA-B0WFBS-1500X-X12

BEG2PA-B0WFBS-1500X-X12

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Orange (I/0 & On/Off)
  • Voltages for Illuminated Rocker Units: 32 - 50V DC Terminal Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BEG6MM-B0Y1AD-1600X-X12

BEG6MM-B0Y1AD-1600X-X12

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Clamp Terminal
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Red (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: 100 - 110V AC Lead Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (Dual Rated)
  • Main Circuit Current Ratings: 16A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BEH1ED-B0YEAS-1000X-X11

BEH1ED-B0YEAS-1000X-X11

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Red (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: 24 - 32V DC Terminal Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BEH1ED-B0YEAS-1500X-X11

BEH1ED-B0YEAS-1500X-X11

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Red (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: 24 - 32V DC Terminal Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BEH1MM-B0A1AW-1200X-X12

BEH1MM-B0A1AW-1200X-X12

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Green (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: 100 - 110V AC Lead Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AD + Inertia Delay)
  • Main Circuit Current Ratings: 12A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BEH1MM-B0AAAW-0500X-X12

BEH1MM-B0AAAW-0500X-X12

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Green (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: 100 - 125V AC Terminal Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AD + Inertia Delay)
  • Main Circuit Current Ratings: 5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BEH1MM-B0AAAW-1200X-X12

BEH1MM-B0AAAW-1200X-X12

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Green (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: 100 - 125V AC Terminal Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AD + Inertia Delay)
  • Main Circuit Current Ratings: 12A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BEH1MM-B0ABAW-0600X-X12

BEH1MM-B0ABAW-0600X-X12

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Green (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: 200 - 240V AC Terminal Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AD + Inertia Delay)
  • Main Circuit Current Ratings: 6A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BEH1MM-B0T2BD-500MX-XXX

BEH1MM-B0T2BD-500MX-XXX

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Red (On - Off)
  • Voltages for Illuminated Rocker Units: 200 - 240V AC Lead Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
  • Main Circuit Current Ratings: 500mA
  • Relay Trip Coils: Not Applicable

BEH1MM-B0T3BD-2500X-X12

BEH1MM-B0T3BD-2500X-X12

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Red (On - Off)
  • Voltages for Illuminated Rocker Units: 4 - 8V DC Lead Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BEH1PA-B0BBBS-0100X-X12

BEH1PA-B0BBBS-0100X-X12

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Green (I - O)
  • Voltages for Illuminated Rocker Units: 200 - 240V AC Terminal Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 1A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BEH1PA-B0H1CI-0400X-X12

BEH1PA-B0H1CI-0400X-X12

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Red (I - O)
  • Voltages for Illuminated Rocker Units: 100 - 110V AC Lead Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 4A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BEH1PA-B0H1CI-0700X-X12

BEH1PA-B0H1CI-0700X-X12

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Red (I - O)
  • Voltages for Illuminated Rocker Units: 100 - 110V AC Lead Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 7A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BEH1PA-B0H3BS-1500X-X12

BEH1PA-B0H3BS-1500X-X12

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Red (I - O)
  • Voltages for Illuminated Rocker Units: 4 - 8V DC Lead Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BEH1PA-B0H3CI-1250X-X12

BEH1PA-B0H3CI-1250X-X12

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Red (I - O)
  • Voltages for Illuminated Rocker Units: 4 - 8V DC Lead Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 12.5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BEH1PA-B0N2OP-1600X-XXX

BEH1PA-B0N2OP-1600X-XXX

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (On - Off)
  • Voltages for Illuminated Rocker Units: 200 - 240V AC Lead Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Instantaneous
  • Main Circuit Current Ratings: 16A
  • Relay Trip Coils: Not Applicable

BEH1PA-B0N2OP-2000X-XXX

BEH1PA-B0N2OP-2000X-XXX

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (On - Off)
  • Voltages for Illuminated Rocker Units: 200 - 240V AC Lead Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Instantaneous
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable

BEH1PA-B0Y2CS-0300X-X11

BEH1PA-B0Y2CS-0300X-X11

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Red (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: 200 - 240V AC Lead Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 3A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BEH1PA-B0Y2CS-0500X-X11

BEH1PA-B0Y2CS-0500X-X11

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Red (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: 200 - 240V AC Lead Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BEH1PA-B0Y3CS-0500X-X12

BEH1PA-B0Y3CS-0500X-X12

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Red (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: 4 - 8V DC Lead Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BEH2MM-B0W1BD-0500X-X12

BEH2MM-B0W1BD-0500X-X12

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Orange (I/0 & On/Off)
  • Voltages for Illuminated Rocker Units: 100 - 110V AC Lead Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
  • Main Circuit Current Ratings: 5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BEH2MM-B0W1BD-1000X-X12

BEH2MM-B0W1BD-1000X-X12

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Orange (I/0 & On/Off)
  • Voltages for Illuminated Rocker Units: 100 - 110V AC Lead Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BEH2MM-B0Y2CD-1000X-X12

BEH2MM-B0Y2CD-1000X-X12

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Red (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: 200 - 240V AC Lead Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (Dual Rated)
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BEH2MM-B0Y2CD-2000X-X12

BEH2MM-B0Y2CD-2000X-X12

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Red (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: 200 - 240V AC Lead Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (Dual Rated)
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BEH2PA-B0K1AS-0300X-X11

BEH2PA-B0K1AS-0300X-X11

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (I/0 & On/Off)
  • Voltages for Illuminated Rocker Units: 100 - 110V AC Lead Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 3A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BEH2PA-B0KBAS-0300X-X12

BEH2PA-B0KBAS-0300X-X12

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (I/0 & On/Off)
  • Voltages for Illuminated Rocker Units: 200 - 240V AC Terminal Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 3A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BEH2PA-B0W1CS-0500X-X11

BEH2PA-B0W1CS-0500X-X11

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Orange (I/0 & On/Off)
  • Voltages for Illuminated Rocker Units: 100 - 110V AC Lead Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BEH2PA-B0W2CS-0300X-X11

BEH2PA-B0W2CS-0300X-X11

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Orange (I/0 & On/Off)
  • Voltages for Illuminated Rocker Units: 200 - 240V AC Lead Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 3A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BEH2PA-B1YBAS-1000X-X11

BEH2PA-B1YBAS-1000X-X11

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
  • Handle, Indicator Color & Marking: Red (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: 200 - 240V AC Terminal Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BEM1PA-B0A1AI-2500X-X11

BEM1PA-B0A1AI-2500X-X11

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Horizontal Mounting (Without Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Green (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: 100 - 110V AC Lead Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BEM1PA-B0A4CI-2500X-X11

BEM1PA-B0A4CI-2500X-X11

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Horizontal Mounting (Without Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Green (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: 16 - 24V DC Lead Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BEM1PA-B0H1BS-0350X-X12

BEM1PA-B0H1BS-0350X-X12

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Horizontal Mounting (Without Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Red (I - O)
  • Voltages for Illuminated Rocker Units: 100 - 110V AC Lead Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 3.5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BEM1PA-B0H1BS-1500X-X12

BEM1PA-B0H1BS-1500X-X12

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Horizontal Mounting (Without Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Red (I - O)
  • Voltages for Illuminated Rocker Units: 100 - 110V AC Lead Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BEM2PA-B0BACS-1500X-X12

BEM2PA-B0BACS-1500X-X12

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Horizontal Mounting (Without Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Green (I - O)
  • Voltages for Illuminated Rocker Units: 100 - 125V AC Terminal Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BEM2PA-B0IBAS-2500X-X11

BEM2PA-B0IBAS-2500X-X11

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Horizontal Mounting (Without Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Blue (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: 200 - 240V AC Terminal Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BEN1PA-B0Y1CS-1500X-X12

BEN1PA-B0Y1CS-1500X-X12

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Horizontal Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Red (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: 100 - 110V AC Lead Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BEN1PA-B0Y1CS-2500X-X12

BEN1PA-B0Y1CS-2500X-X12

  • Frame and Handle Description: Black Body, Illum Rocker Handle
  • Mounting: Snap-in Horizontal Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Red (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: 100 - 110V AC Lead Connectors
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Pages

Looking for a distributor?

Visit our map-based Distributor search to find your closest supplier. Our carefully-selected distributors help you find the right circuit breaker for your needs

Find a distributor

 

Bulk & Custom Products

Are you an equipment manufacturer in telecoms or construction? If you are looking for custom configurations or bulk purchases, please contact our sales team.

Contact us

Protect your assets

Superior circuit breakers for equipment.