D-2A2MXANAS-K100-LXC-XXXXXBDVAX2-X

D-2A2MXANAS-K100-LXC-XXXXXBDVAX2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle - Mid Trip
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 100A
  • Circuit Configuration: Mid Trip Handle and Trip Alarm
  • Switches: V4D - Silver Tips, Offset Terminals, 4.75mm (0.189") - (10A @ 250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2A2MXANBS-0100-LXB-XXXXXBDVAX2-X

D-2A2MXANBS-0100-LXB-XXXXXBDVAX2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle - Mid Trip
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 1A
  • Circuit Configuration: Mid Trip Handle and Trip Alarm
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2A2MXANBS-0300-LXB-XXXXXBDVAX2-X

D-2A2MXANBS-0300-LXB-XXXXXBDVAX2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle - Mid Trip
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 3A
  • Circuit Configuration: Mid Trip Handle and Trip Alarm
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2A2MXANBS-0500-LXB-XXXXXBDVAX2-X

D-2A2MXANBS-0500-LXB-XXXXXBDVAX2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle - Mid Trip
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 5A
  • Circuit Configuration: Mid Trip Handle and Trip Alarm
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2A2MXANBS-2000-LXB-XXXXXBDVAX2-X

D-2A2MXANBS-2000-LXB-XXXXXBDVAX2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle - Mid Trip
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Mid Trip Handle and Trip Alarm
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2A2MXANBS-3000-LXB-XXXXXBDVAX2-X

D-2A2MXANBS-3000-LXB-XXXXXBDVAX2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle - Mid Trip
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Mid Trip Handle and Trip Alarm
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2A2MXANBS-3500-LBB-XXXXXWDVAX2-X

D-2A2MXANBS-3500-LBB-XXXXXWDVAX2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle - Mid Trip
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 35A
  • Circuit Configuration: Mid Trip Handle and Aux Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2A2MXANBS-5000-LXB-XXXXXBDVAX2-X

D-2A2MXANBS-5000-LXB-XXXXXBDVAX2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle - Mid Trip
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Mid Trip Handle and Trip Alarm
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2A2MXANBS-500M-LXB-XXXXXBDVAX2-X

D-2A2MXANBS-500M-LXB-XXXXXBDVAX2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle - Mid Trip
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 500mA
  • Circuit Configuration: Mid Trip Handle and Trip Alarm
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2A2MXANBS-7000-LBB-XXXXXBDVAX2-C

D-2A2MXANBS-7000-LBB-XXXXXBDVAX2-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle - Mid Trip
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 70A
  • Circuit Configuration: Mid Trip Handle and Aux Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2A2MXANBS-7000-LXB-XXXXXBDVAX2-X

D-2A2MXANBS-7000-LXB-XXXXXBDVAX2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle - Mid Trip
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 70A
  • Circuit Configuration: Mid Trip Handle and Trip Alarm
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2A2MXANBS-K100-LXB-XXXXXBDVAX2-C

D-2A2MXANBS-K100-LXB-XXXXXBDVAX2-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle - Mid Trip
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 100A
  • Circuit Configuration: Mid Trip Handle and Trip Alarm
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2A2V1BNAS-K150-LAM-XXXXXBDVAX3-X

D-2A2V1BNAS-K150-LAM-XXXXXBDVAX3-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle - Mid Trip
  • Termination: Bridge Terminal - 2 pole parallel M6 or 1/4-20 Stud Terminal
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 150A
  • Circuit Configuration: Mid Trip Handle
  • Switches: Parallel Bridge Housing - For all Parallel Bridged Poles
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: UL listed (UL489A), IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2A2V1BNAS-K150-LXC-XXXXXBDVAX3-X

D-2A2V1BNAS-K150-LXC-XXXXXBDVAX3-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle - Mid Trip
  • Termination: Bridge Terminal - 2 pole parallel M6 or 1/4-20 Stud Terminal
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 150A
  • Circuit Configuration: Mid Trip Handle and Trip Alarm
  • Switches: V4D - Silver Tips, Offset Terminals, 4.75mm (0.189") - (10A @ 250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: UL listed (UL489A), IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2A2V1BNAS-K200-LAM-XXXXXBDVAX3-X

D-2A2V1BNAS-K200-LAM-XXXXXBDVAX3-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle - Mid Trip
  • Termination: Bridge Terminal - 2 pole parallel M6 or 1/4-20 Stud Terminal
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 200A
  • Circuit Configuration: Mid Trip Handle
  • Switches: Parallel Bridge Housing - For all Parallel Bridged Poles
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: UL listed (UL489A), IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2A2V1BNAS-K200-LXC-XXXXXBDVAX3-X

D-2A2V1BNAS-K200-LXC-XXXXXBDVAX3-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle - Mid Trip
  • Termination: Bridge Terminal - 2 pole parallel M6 or 1/4-20 Stud Terminal
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 200A
  • Circuit Configuration: Mid Trip Handle and Trip Alarm
  • Switches: V4D - Silver Tips, Offset Terminals, 4.75mm (0.189") - (10A @ 250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: UL listed (UL489A), IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2A2V1BNCS-K200-HXM-B2DXXBDVAX3-X

D-2A2V1BNCS-K200-HXM-B2DXXBDVAX3-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle - Mid Trip
  • Termination: Bridge Terminal - 2 pole parallel M6 or 1/4-20 Stud Terminal
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Short Time Delay 50/60Hz or DC
  • Main Circuit Current: 200A
  • Circuit Configuration: Dual Control - Relay Trip Construction (4 terminal)
  • Switches: Parallel Bridge Housing - For all Parallel Bridged Poles
  • Voltages & Coil Ratings (Dual Control): 48V DC
  • Voltages & Coil Ratings (Dual Control): Flying Leads (wire terminals)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: UL listed (UL489A), IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2A2V1BNCS-K200-LBC-XXXXXBDVAX3-X

D-2A2V1BNCS-K200-LBC-XXXXXBDVAX3-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle - Mid Trip
  • Termination: Bridge Terminal - 2 pole parallel M6 or 1/4-20 Stud Terminal
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Short Time Delay 50/60Hz or DC
  • Main Circuit Current: 200A
  • Circuit Configuration: Mid Trip Handle and Aux Switch
  • Switches: V4D - Silver Tips, Offset Terminals, 4.75mm (0.189") - (10A @ 250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: UL listed (UL489A), IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2AAAX2NCS-0300-BXX-XXXXXBDVAC2-C

D-2AAAX2NCS-0300-BXX-XXXXXBDVAC2-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Short Time Delay 50/60Hz or DC
  • Main Circuit Current: 3A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2AAAX2NCS-0500-BXX-XXXXXBDVAC2-C

D-2AAAX2NCS-0500-BXX-XXXXXBDVAC2-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Short Time Delay 50/60Hz or DC
  • Main Circuit Current: 5A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2AAAX2SAH-1000-BXX-XXXXXBCVAC2-X

D-2AAAX2SAH-1000-BXX-XXXXXBCVAC2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz
  • Main Circuit Current: 10A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2AAAX2SAH-1500-BXX-XXXXXBCVAC2-X

D-2AAAX2SAH-1500-BXX-XXXXXBCVAC2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz
  • Main Circuit Current: 15A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2AAAX2SAH-2000-BXX-XXXXXBCVAC2-X

D-2AAAX2SAH-2000-BXX-XXXXXBCVAC2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2AAAX3RAH-6000-BXX-XXXXXBDVAA1-X

D-2AAAX3RAH-6000-BXX-XXXXXBDVAA1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz
  • Main Circuit Current: 60A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-SMALL
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2AAAXAJAE-5000-BXX-XXXXXBH1BX2-X

D-2AAAXAJAE-5000-BXX-XXXXXBH1BX2-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Long Time Delay 50/60Hz (AH + Inertia Delay)
  • Main Circuit Current: 50A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical Reverse Mounting , Line @ Bottom
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2AAAXAJBI-1500-BXX-XXXXXBBVAX1-X

D-2AAAXAJBI-1500-BXX-XXXXXBBVAX1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC (BS + Inertia Delay)
  • Main Circuit Current: 15A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2AAAXAJBI-2000-BXX-XXXXXBBVAX1-X

D-2AAAXAJBI-2000-BXX-XXXXXBBVAX1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC (BS + Inertia Delay)
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2AAAXAJBI-3000-BXX-XXXXXBBVAX1-X

D-2AAAXAJBI-3000-BXX-XXXXXBBVAX1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC (BS + Inertia Delay)
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2AAAXAJBS-1670-H1B-A1DXXBCVAX1-X

D-2AAAXAJBS-1670-H1B-A1DXXBCVAX1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 16.7A
  • Circuit Configuration: Dual Control - Relay Trip - Fly Leads for Relay Trip - Auxiliary Switch (4 terminal)
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • Voltages & Coil Ratings (Dual Control): 12V AC 50/60Hz
  • Voltages & Coil Ratings (Dual Control): Flying Leads (wire terminals)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2AAAXAKBI-0500-BXX-XXXXXBDVAX1-X

D-2AAAXAKBI-0500-BXX-XXXXXBDVAX1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240Vac; 277Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC (BS + Inertia Delay)
  • Main Circuit Current: 5A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2AAAXAKBI-1000-BXX-XXXXXBDVAX1-X

D-2AAAXAKBI-1000-BXX-XXXXXBDVAX1-X

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240Vac; 277Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC (BS + Inertia Delay)
  • Main Circuit Current: 10A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2AAAXAKBS-0150-BXX-XXXXXBDVAX1-C

D-2AAAXAKBS-0150-BXX-XXXXXBDVAX1-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240Vac; 277Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 1.5A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

D-2AAAXAKBS-0300-BXX-XXXXXBDVAX1-C

D-2AAAXAKBS-0300-BXX-XXXXXBDVAX1-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240Vac; 277Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 3A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

D-2AAAXAKBS-0500-BXX-XXXXXBDVAX1-C

D-2AAAXAKBS-0500-BXX-XXXXXBDVAX1-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240Vac; 277Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 5A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

D-2AAAXAKBS-0600-BXX-XXXXXBDVAX1-C

D-2AAAXAKBS-0600-BXX-XXXXXBDVAX1-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240Vac; 277Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 6A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

D-2AAAXAKBS-0750-BXX-XXXXXBDVAX1-C

D-2AAAXAKBS-0750-BXX-XXXXXBDVAX1-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240Vac; 277Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 7.5A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

D-2AAAXAKBS-1250-BXX-XXXXXBDVAX1-C

D-2AAAXAKBS-1250-BXX-XXXXXBDVAX1-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240Vac; 277Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 12.5A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

D-2AAAXAKBS-1500-BXX-XXXXXBDVAX1-C

D-2AAAXAKBS-1500-BXX-XXXXXBDVAX1-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240Vac; 277Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 15A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

D-2AAAXAKBS-2000-BXX-XXXXXBDVAX1-C

D-2AAAXAKBS-2000-BXX-XXXXXBDVAX1-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240Vac; 277Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

D-2AAAXAKBS-3500-BXX-XXXXXBDVAX1-C

D-2AAAXAKBS-3500-BXX-XXXXXBDVAX1-C

  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240Vac; 277Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 35A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

Pages

Looking for a distributor?

Visit our map-based Distributor search to find your closest supplier. Our carefully-selected distributors help you find the right circuit breaker for your needs

Find a distributor

 

Bulk & Custom Products

Are you an equipment manufacturer in telecoms or construction? If you are looking for custom configurations or bulk purchases, please contact our sales team.

Contact us

Protect your assets

Superior circuit breakers for equipment.