info@cbibreakers.com  🗲 salesasia@cbi-electric.com (Asia)
600 Eagleview Blvd, Exton, PA 19341  🗲  +1 610 524 9949

No of Poles

Current Rating

Voltage Rating AC

Voltage Rating DC

Frequency

Circuit Type

Mounting

Actuator Handle

Termination

Trip Characteristics

Filter by frame:

CBi Search: A-Z List

This searchable catalog shows pre-configured, popular products already in our system.

For custom configurations, please contact us. We recommend that you identify products closest to your requirements, and then order a sample noting your custom configuration. Our representative will contact you.

HTabGroup

A - Z (Full Detail)
Displaying 251 - 260 of 2252

If no results are displayed, please adjust your choices on the left. The first selections might be slow, as there are thousands of records to load! As you select, each remaining search parameter will recalculate.

BDH1FD-B1KXCS-0100X-X32

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
0.1 - 5 A
Frequency: 
DC only
Voltage Rating DC: 
61 - 80V DC
Mounting: 
Snap In
Termination: 
Quick connect
Trip Characteristics
Trip Characteristics: 
Fast
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 80V Polarity Sensitive (0.6kA) MKI
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
  • Handle, Indicator Color & Marking: White (I/0 & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 1A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL 489A, UL508, IEC60934,VDE & CE
  • Safety Marks: No Safety Mark
Order Sample

BDH1FD-B1KXCS-0500X-X32

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
0.1 - 5 A
Frequency: 
DC only
Voltage Rating DC: 
61 - 80V DC
Mounting: 
Snap In
Termination: 
Quick connect
Trip Characteristics
Trip Characteristics: 
Fast
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 80V Polarity Sensitive (0.6kA) MKI
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
  • Handle, Indicator Color & Marking: White (I/0 & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL 489A, UL508, IEC60934,VDE & CE
  • Safety Marks: No Safety Mark
Order Sample

BDH1FD-B1LXAS-3000X-X32

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
16 - 30 A
Frequency: 
DC only
Voltage Rating DC: 
61 - 80V DC
Mounting: 
Snap In
Termination: 
Quick connect
Trip Characteristics
Trip Characteristics: 
Slow
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 80V Polarity Sensitive (0.6kA) MKI
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 30A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL 489A, UL508, IEC60934,VDE & CE
  • Safety Marks: No Safety Mark
Order Sample

BDH1FD-B1LXBS-0600X-X31

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
6 - 15 A
Frequency: 
DC only
Voltage Rating DC: 
61 - 80V DC
Mounting: 
Snap In
Termination: 
Quick connect
Trip Characteristics
Trip Characteristics: 
Medium
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 80V Polarity Sensitive (0.6kA) MKI
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 6A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL 489A, UL508, IEC60934,VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Order Sample

BDH1FD-B1LXBS-0800X-X31

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
6 - 15 A
Frequency: 
DC only
Voltage Rating DC: 
61 - 80V DC
Mounting: 
Snap In
Termination: 
Quick connect
Trip Characteristics
Trip Characteristics: 
Medium
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 80V Polarity Sensitive (0.6kA) MKI
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 8A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL 489A, UL508, IEC60934,VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Order Sample

BDH1FD-B1LXBS-1000X-X32

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
6 - 15 A
Frequency: 
DC only
Voltage Rating DC: 
61 - 80V DC
Mounting: 
Snap In
Termination: 
Quick connect
Trip Characteristics
Trip Characteristics: 
Medium
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 80V Polarity Sensitive (0.6kA) MKI
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL 489A, UL508, IEC60934,VDE & CE
  • Safety Marks: No Safety Mark
Order Sample

BDH1FD-B1WXBS-3000X-X31

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
16 - 30 A
Frequency: 
DC only
Voltage Rating DC: 
61 - 80V DC
Mounting: 
Snap In
Termination: 
Quick connect
Trip Characteristics
Trip Characteristics: 
Medium
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 80V Polarity Sensitive (0.6kA) MKI
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
  • Handle, Indicator Color & Marking: Orange (I/0 & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 30A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL 489A, UL508, IEC60934,VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Order Sample

BDH1FD-B1YXBS-0100X-X32

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
0.1 - 5 A
Frequency: 
DC only
Voltage Rating DC: 
61 - 80V DC
Mounting: 
Snap In
Termination: 
Quick connect
Trip Characteristics
Trip Characteristics: 
Medium
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 80V Polarity Sensitive (0.6kA) MKI
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
  • Handle, Indicator Color & Marking: Red (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 1A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL 489A, UL508, IEC60934,VDE & CE
  • Safety Marks: No Safety Mark
Order Sample

BDH1FD-B1YXBS-0200X-X32

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
0.1 - 5 A
Frequency: 
DC only
Voltage Rating DC: 
61 - 80V DC
Mounting: 
Snap In
Termination: 
Quick connect
Trip Characteristics
Trip Characteristics: 
Medium
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 80V Polarity Sensitive (0.6kA) MKI
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
  • Handle, Indicator Color & Marking: Red (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 2A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL 489A, UL508, IEC60934,VDE & CE
  • Safety Marks: No Safety Mark
Order Sample

BDH1FD-B1YXBS-1000X-X32

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
6 - 15 A
Frequency: 
DC only
Voltage Rating DC: 
61 - 80V DC
Mounting: 
Snap In
Termination: 
Quick connect
Trip Characteristics
Trip Characteristics: 
Medium
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 80V Polarity Sensitive (0.6kA) MKI
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
  • Handle, Indicator Color & Marking: Red (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL 489A, UL508, IEC60934,VDE & CE
  • Safety Marks: No Safety Mark
Order Sample

Pages

Accordion View
Displaying 1251 - 1300 of 2252

If no results are displayed, please adjust your choices on the left. The first selections might be slow, as there are thousands of records to load! As you select, each remaining search parameter will recalculate.

Part No: D-2AAMXANAS-K100-KXB-XXXXXBDVAX2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 100A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

Part No: D-2AAMXANBS-2000-KXB-XXXXXBDVAX2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2AAMXANBS-4000-KXB-XXXXXBDVAX2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 40A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2AAMXANBS-5000-KXB-XXXXXBDVAX2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2AAMXANBS-6000-KXB-XXXXXBDVAX2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 60A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2AAMXANBS-7000-KXB-XXXXXBDVAX2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 70A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2AAMXANBS-K100-BXX-XXXXXBDVAX2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 100A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

Part No: D-2AAMXANCI-K100-KXB-XXXXXBDVAX2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Short Time Delay 50/60Hz or DC (CS + Inertia Delay)
  • Main Circuit Current: 100A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2AAMXASBS-1500-BXX-XXXXXBDVAX2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 15A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2AAMXASBS-3000-BXX-XXXXX4DVAX2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Blue handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2AAMXASBS-3000-BXX-XXXXXBDVAX2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2AAMXASBS-3000-BXX-XXXXXRDVAX2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Red handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2AAMXBJBS-4000-BXX-XXXXXBDVAA1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 40A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-SMALL
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

Part No: D-2AAMXBJBS-6000-BXX-XXXXXBDVAA1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 60A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-SMALL
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

Part No: D-2AAMXBMBD-6000-BXX-XXXXXBDVAX1-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: AC & DC Multipole (80Vdc, 240/415Vac & 277/480Vac)
  • Time Delay : Medium Time Delay 50/60Hz/DC
  • Main Circuit Current: 60A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

Part No: D-2AAMXBNAS-8000-HXX-A4FXXBHVAC1-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 80A
  • Circuit Configuration: Dual Control - Relay Trip Construction (4 terminal)
  • Voltages & Coil Ratings (Dual Control): 110-125V AC 50/60Hz
  • Voltages & Coil Ratings (Dual Control): Stud Terminals (M6 / 1/4-20)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

Part No: D-2AAMXBNAS-8000-KXB-XXXXXBHVAC1-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 80A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

Part No: D-2AAMXBNAS-K100-HXX-A4FXXBDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 100A
  • Circuit Configuration: Dual Control - Relay Trip Construction (4 terminal)
  • Voltages & Coil Ratings (Dual Control): 110-125V AC 50/60Hz
  • Voltages & Coil Ratings (Dual Control): Stud Terminals (M6 / 1/4-20)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2AAMXBNAS-K100-KXB-XXXXXBDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 100A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2AAMXBNBS-9000-BXX-XXXXXBDVAX2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 90A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2AAMXBNBS-K100-BXX-XXXXXBDVAX2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 100A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2AAMXBNBS-K175-BXX-XXXXXBDVAX3-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 175A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: UL listed (UL489A), IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2AAMXBNBS-K200-BXM-XXXXXBDVAX3-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 200A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • Switches: Parallel Bridge Housing - For all Parallel Bridged Poles
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: UL listed (UL489A), IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

Part No: D-2AAMXBNBS-K200-KXC-XXXXXBDVAX3-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 200A
  • Circuit Configuration: Auxiliary Switch
  • Switches: V4D - Silver Tips, Offset Terminals, 4.75mm (0.189") - (10A @ 250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: UL listed (UL489A), IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

Part No: D-2AAMXBQAH-1500-BXX-XXXXXBHVAB1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac
  • Time Delay : Long Time Delay 50/60Hz
  • Main Circuit Current: 15A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

Part No: D-2AAMXBQAH-2000-BXX-XXXXXBHVAB1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac
  • Time Delay : Long Time Delay 50/60Hz
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

Part No: D-2AAMXBQAH-6000-BXX-XXXXXBHVAB1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac
  • Time Delay : Long Time Delay 50/60Hz
  • Main Circuit Current: 60A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

Part No: D-2AAMXBRAS-4000-BXX-XXXXXBDVAC1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 40A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

Part No: D-2AAMXBRAS-4000-HXX-A4FXXBDVAC1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 40A
  • Circuit Configuration: Dual Control - Relay Trip Construction (4 terminal)
  • Voltages & Coil Ratings (Dual Control): 110-125V AC 50/60Hz
  • Voltages & Coil Ratings (Dual Control): Stud Terminals (M6 / 1/4-20)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

Part No: D-2AAMXBRBS-7000-BXX-XXXXXBDVAC1-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 70A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

Part No: D-2AAMXBSAS-8000-BXX-XXXXXBDVACZ-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 80A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: No approvals; Not for Commercial Sale without Prior arrangement with Manufacturer
  • Safety marks: Not Applicable

Part No: D-2AAMXBSAS-8000-HXX-A4FXXBDVACZ-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 80A
  • Circuit Configuration: Dual Control - Relay Trip Construction (4 terminal)
  • Voltages & Coil Ratings (Dual Control): 110-125V AC 50/60Hz
  • Voltages & Coil Ratings (Dual Control): Stud Terminals (M6 / 1/4-20)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: No approvals; Not for Commercial Sale without Prior arrangement with Manufacturer
  • Safety marks: Not Applicable

Part No: D-2AAMXBSBS-2000-BXX-XXXXXBDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2AAMXBSBS-5000-BXX-XXXXXBDVAA2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-SMALL
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

Part No: D-2AAMXCJAS-9000-BXX-XXXXXBCVAXZ-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 90A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: No approvals; Not for Commercial Sale without Prior arrangement with Manufacturer
  • Safety marks: Not Applicable

Part No: D-2AAMXCJAS-9000-DXX-B4CXXBCVAXZ-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 90A
  • Circuit Configuration: Switch Relay Trip Voltages Snsing - Centre Terminal Construction (4 Terminal)
  • Voltages & Coil Ratings (Dual Control): 6 - 125V DC
  • Voltages & Coil Ratings (Dual Control): Quick Connect Terminals (0.8mm x 6.35mm)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: No approvals; Not for Commercial Sale without Prior arrangement with Manufacturer
  • Safety marks: Not Applicable

Part No: D-2AAMXCQAH-0500-BXX-XXXXXBDHAB1-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac
  • Time Delay : Long Time Delay 50/60Hz
  • Main Circuit Current: 5A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

Part No: D-2AAMXCQAH-5000-BXX-XXXXXBDHAB1-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac
  • Time Delay : Long Time Delay 50/60Hz
  • Main Circuit Current: 50A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

Part No: D-2AAMXCQAH-7000-BXX-XXXXXBDHAB1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac
  • Time Delay : Long Time Delay 50/60Hz
  • Main Circuit Current: 70A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

Part No: D-2AAMXCQBS-7000-BXX-XXXXXBDVAC1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 70A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

Part No: D-2AAMXCRAH-3000-BXX-XXXXXBD1AC1-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical Reverse Mounting , Line @ Bottom
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

Part No: D-2AAMXCRAI-3200-BXX-XXXXXWDVAB1-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60hz or DC (AS + Inertia Delay)
  • Main Circuit Current: 32A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

Part No: D-2AAMXCRAI-6300-BXX-XXXXXWDVAB1-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60hz or DC (AS + Inertia Delay)
  • Main Circuit Current: 63A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

Part No: D-2AAMXCRAI-6300-KXB-XXXXXWDVAB1-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60hz or DC (AS + Inertia Delay)
  • Main Circuit Current: 63A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

Part No: D-2AAMXCRBS-7000-BXX-XXXXXBDVAC1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 70A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

Part No: D-2AAMXCRBS-K100-BXX-XXXXXBDVAAZ-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 100A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-SMALL
  • Approvals: No approvals; Not for Commercial Sale without Prior arrangement with Manufacturer
  • Safety marks: Not Applicable

Part No: D-2AAMXCRCS-7000-BXX-XXXXXBDVAB1-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Short Time Delay 50/60Hz or DC
  • Main Circuit Current: 70A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

Part No: D-2AAMXCROP-5000-BXX-XXXXXBDVAC1-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Instantaneous Trip 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

Part No: D-2AAMXCROP-5000-BXX-XXXXXBDVAC1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Instantaneous Trip 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

Part No: D-2AAMXCROP-7000-BXX-XXXXXBDVAC1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Instantaneous Trip 50/60Hz or DC
  • Main Circuit Current: 70A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

Pages

List View
Displaying 751 - 780 of 2252

If no results are displayed, please adjust your choices on the left. The first selections might be slow, as there are thousands of records to load! As you select, each remaining search parameter will recalculate.

Part No No of Poles Framesort descending View/Order Termination
BGQ2MM-B0ZXAD-1000X-X12 2 B-Frame Quick connect
BGQ2PA-B02XAI-1000X-X11 2 B-Frame Quick connect
BGQ2PA-B02XBS-2000X-X12 2 B-Frame Quick connect
BGQ2PA-B02XBS-0500X-X11 2 B-Frame Quick connect
BGQ2PA-B03XAI-0300X-X11 2 B-Frame Quick connect
BGQ2PA-B0ZXBS-1000X-X12 2 B-Frame Quick connect
BGQ2PA-B12XAS-2000X-X11 2 B-Frame Quick connect
BGQ2PA-B33XBS-0800X-X12 2 B-Frame Quick connect
BGQDPA-B0ZXBS-0100X-X12 2 B-Frame Screw: straight
BVQBED-B07XCS-3000X-X22 2 B-Frame Screw: bent
BAABED-B03XAS-2000X-X11 2 B-Frame Screw: bent
BAADPA-B03XBS-0100X-X12 2 B-Frame Screw: straight
BBA2MM-B02XBD-2000X-XXX 2 B-Frame Quick connect
BCABED-B02XAS-2000X-X11 2 B-Frame Screw: bent
BZA2ED-B03XCS-3000X-X12 2 B-Frame Quick connect
BZA2PA-B03XAS-1600X-X12 2 B-Frame Quick connect
BZA2PA-B03XAS-2000X-X12 2 B-Frame Quick connect
BZA2PA-B03XAS-2500X-X12 2 B-Frame Quick connect
BZABPA-B03XCS-1000X-X12 2 B-Frame Screw: bent
BZADMM-B03XAD-2500X-X12 2 B-Frame Screw: straight
BDHZPA-B0ZXAS-2000X-X12 B-Frame
BDNZPA-B3DXBS-2000X-X12 B-Frame
C-A2A32AJAS-1500-BXX-XXXXXWDVBX1-X 1 C-Frame Screw: upturned ears
C-A2A32AMBD-2000-BXX-XXXXXWCVBX1-X 1 C-Frame Screw: upturned ears
C-A2A32AJAS-2000-BXX-XXXXXWDVBX1-X 1 C-Frame Screw: upturned ears
C-A2A52AMCW-0200-BXX-XXXXXWCVBX1-X 1 C-Frame Screw: bent
C-A2A52AMCW-0300-BXX-XXXXXWCVBX1-X 1 C-Frame Screw: bent
C-A2A52AMCW-0400-BXX-XXXXXWCVBX1-X 1 C-Frame Screw: bent
C-A2A52AMCW-0500-BXX-XXXXXWCVBX1-X 1 C-Frame Screw: bent
C-A2A52AMCW-0900-BXX-XXXXXWCVBX1-X 1 C-Frame Screw: bent

Pages

Keyword Search

Add a space between keywords.

Displaying 1251 - 1300 of 2247

D-2AAMXANBS-7000-KXB-XXXXXBDVAX2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 70A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2AAMXANBS-K100-BXX-XXXXXBDVAX2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 100A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2AAMXANCI-K100-KXB-XXXXXBDVAX2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Short Time Delay 50/60Hz or DC (CS + Inertia Delay)
  • Main Circuit Current: 100A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2AAMXASBS-1500-BXX-XXXXXBDVAX2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 15A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2AAMXASBS-3000-BXX-XXXXX4DVAX2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Blue handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2AAMXASBS-3000-BXX-XXXXXBDVAX2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2AAMXASBS-3000-BXX-XXXXXRDVAX2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Red handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2AAMXBJBS-4000-BXX-XXXXXBDVAA1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 40A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-SMALL
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2AAMXBJBS-6000-BXX-XXXXXBDVAA1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 60A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-SMALL
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2AAMXBMBD-6000-BXX-XXXXXBDVAX1-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: AC & DC Multipole (80Vdc, 240/415Vac & 277/480Vac)
  • Time Delay : Medium Time Delay 50/60Hz/DC
  • Main Circuit Current: 60A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

D-2AAMXBNAS-8000-HXX-A4FXXBHVAC1-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 80A
  • Circuit Configuration: Dual Control - Relay Trip Construction (4 terminal)
  • Voltages & Coil Ratings (Dual Control): 110-125V AC 50/60Hz
  • Voltages & Coil Ratings (Dual Control): Stud Terminals (M6 / 1/4-20)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

D-2AAMXBNAS-8000-KXB-XXXXXBHVAC1-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 80A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

D-2AAMXBNAS-K100-HXX-A4FXXBDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 100A
  • Circuit Configuration: Dual Control - Relay Trip Construction (4 terminal)
  • Voltages & Coil Ratings (Dual Control): 110-125V AC 50/60Hz
  • Voltages & Coil Ratings (Dual Control): Stud Terminals (M6 / 1/4-20)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2AAMXBNAS-K100-KXB-XXXXXBDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 100A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2AAMXBNBS-9000-BXX-XXXXXBDVAX2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 90A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2AAMXBNBS-K100-BXX-XXXXXBDVAX2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 100A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2AAMXBNBS-K175-BXX-XXXXXBDVAX3-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 175A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: UL listed (UL489A), IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2AAMXBNBS-K200-BXM-XXXXXBDVAX3-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 200A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • Switches: Parallel Bridge Housing - For all Parallel Bridged Poles
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: UL listed (UL489A), IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2AAMXBNBS-K200-KXC-XXXXXBDVAX3-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 200A
  • Circuit Configuration: Auxiliary Switch
  • Switches: V4D - Silver Tips, Offset Terminals, 4.75mm (0.189") - (10A @ 250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: UL listed (UL489A), IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2AAMXBQAH-1500-BXX-XXXXXBHVAB1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac
  • Time Delay : Long Time Delay 50/60Hz
  • Main Circuit Current: 15A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2AAMXBQAH-2000-BXX-XXXXXBHVAB1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac
  • Time Delay : Long Time Delay 50/60Hz
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2AAMXBQAH-6000-BXX-XXXXXBHVAB1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac
  • Time Delay : Long Time Delay 50/60Hz
  • Main Circuit Current: 60A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2AAMXBRAS-4000-BXX-XXXXXBDVAC1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 40A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2AAMXBRAS-4000-HXX-A4FXXBDVAC1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 40A
  • Circuit Configuration: Dual Control - Relay Trip Construction (4 terminal)
  • Voltages & Coil Ratings (Dual Control): 110-125V AC 50/60Hz
  • Voltages & Coil Ratings (Dual Control): Stud Terminals (M6 / 1/4-20)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2AAMXBRBS-7000-BXX-XXXXXBDVAC1-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 70A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

D-2AAMXBSAS-8000-BXX-XXXXXBDVACZ-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 80A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: No approvals; Not for Commercial Sale without Prior arrangement with Manufacturer
  • Safety marks: Not Applicable

D-2AAMXBSAS-8000-HXX-A4FXXBDVACZ-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 80A
  • Circuit Configuration: Dual Control - Relay Trip Construction (4 terminal)
  • Voltages & Coil Ratings (Dual Control): 110-125V AC 50/60Hz
  • Voltages & Coil Ratings (Dual Control): Stud Terminals (M6 / 1/4-20)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: No approvals; Not for Commercial Sale without Prior arrangement with Manufacturer
  • Safety marks: Not Applicable

D-2AAMXBSBS-2000-BXX-XXXXXBDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2AAMXBSBS-5000-BXX-XXXXXBDVAA2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-SMALL
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2AAMXCJAS-9000-BXX-XXXXXBCVAXZ-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 90A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: No approvals; Not for Commercial Sale without Prior arrangement with Manufacturer
  • Safety marks: Not Applicable

D-2AAMXCJAS-9000-DXX-B4CXXBCVAXZ-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 90A
  • Circuit Configuration: Switch Relay Trip Voltages Snsing - Centre Terminal Construction (4 Terminal)
  • Voltages & Coil Ratings (Dual Control): 6 - 125V DC
  • Voltages & Coil Ratings (Dual Control): Quick Connect Terminals (0.8mm x 6.35mm)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: No approvals; Not for Commercial Sale without Prior arrangement with Manufacturer
  • Safety marks: Not Applicable

D-2AAMXCQAH-0500-BXX-XXXXXBDHAB1-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac
  • Time Delay : Long Time Delay 50/60Hz
  • Main Circuit Current: 5A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

D-2AAMXCQAH-5000-BXX-XXXXXBDHAB1-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac
  • Time Delay : Long Time Delay 50/60Hz
  • Main Circuit Current: 50A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

D-2AAMXCQAH-7000-BXX-XXXXXBDHAB1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac
  • Time Delay : Long Time Delay 50/60Hz
  • Main Circuit Current: 70A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2AAMXCQBS-7000-BXX-XXXXXBDVAC1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 70A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2AAMXCRAH-3000-BXX-XXXXXBD1AC1-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical Reverse Mounting , Line @ Bottom
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

D-2AAMXCRAI-3200-BXX-XXXXXWDVAB1-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60hz or DC (AS + Inertia Delay)
  • Main Circuit Current: 32A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

D-2AAMXCRAI-6300-BXX-XXXXXWDVAB1-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60hz or DC (AS + Inertia Delay)
  • Main Circuit Current: 63A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

D-2AAMXCRAI-6300-KXB-XXXXXWDVAB1-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60hz or DC (AS + Inertia Delay)
  • Main Circuit Current: 63A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

D-2AAMXCRBS-7000-BXX-XXXXXBDVAC1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 70A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2AAMXCRBS-K100-BXX-XXXXXBDVAAZ-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 100A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-SMALL
  • Approvals: No approvals; Not for Commercial Sale without Prior arrangement with Manufacturer
  • Safety marks: Not Applicable

D-2AAMXCRCS-7000-BXX-XXXXXBDVAB1-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Short Time Delay 50/60Hz or DC
  • Main Circuit Current: 70A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

D-2AAMXCROP-5000-BXX-XXXXXBDVAC1-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Instantaneous Trip 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

D-2AAMXCROP-5000-BXX-XXXXXBDVAC1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Instantaneous Trip 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2AAMXCROP-7000-BXX-XXXXXBDVAC1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Instantaneous Trip 50/60Hz or DC
  • Main Circuit Current: 70A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2AAMXCVBS-K300-BXM-XXXXXBDVAX3-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 60Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 300A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • Switches: Parallel Bridge Housing - For all Parallel Bridged Poles
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: UL listed (UL489A), IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2AAMXCVBS-K300-BXX-XXXXXBDVAX3-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 60Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 300A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: UL listed (UL489A), IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2AAMXCVBS-K300-HXX-B0CXXBDVAX3-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 60Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 300A
  • Circuit Configuration: Dual Control - Relay Trip Construction (4 terminal)
  • Voltages & Coil Ratings (Dual Control): 12V DC
  • Voltages & Coil Ratings (Dual Control): Quick Connect Terminals (0.8mm x 6.35mm)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: UL listed (UL489A), IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2AAMXCVBS-K300-KXB-XXXXXBDVAX3-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 60Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 300A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: UL listed (UL489A), IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2AAV1BNAI-K180-BXM-XXXXXBDVAX3-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Bridge Terminal - 2 pole parallel M6 or 1/4-20 Stud Terminal
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60hz or DC (AS + Inertia Delay)
  • Main Circuit Current: 180A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • Switches: Parallel Bridge Housing - For all Parallel Bridged Poles
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: UL listed (UL489A), IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Pages