This searchable catalog shows pre-configured, popular products already in our system.
For custom configurations, please contact us. We recommend that you identify products closest to your requirements, and then order a sample noting your custom configuration. Our representative will contact you.
HTabGroup
If no results are displayed, please adjust your choices on the left. The first selections might be slow, as there are thousands of records to load! As you select, each remaining search parameter will recalculate.
Part No: D-2SMMX3RBH-4000-BXX-XXXXXWHHB31-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz
- Main Circuit Current: 40A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier and Terminal Cover-LARGE
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2SMMX3RBH-7000-HXX-A5EXXGGHA31-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz
- Main Circuit Current: 70A
- Circuit Configuration: Dual Control - Relay Trip Construction (4 terminal)
- Voltages & Coil Ratings (Dual Control): 220-240V AC 50/60Hz
- Voltages & Coil Ratings (Dual Control): Stud Terminals (M5 / 10-32)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Green handle, White marking
- Handle Marking: On - Off and Amp rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier and Terminal Cover-LARGE
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2SMMXANAS-4000-BXX-XXXXXWHVBX1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 40A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2SMMXANAS-5000-BXX-XXXXXWHVBX1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 50A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2SMMXANAS-6000-BXX-XXXXXWHVBX1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 60A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2SMMXANAS-8000-BXX-XXXXXWHVBX1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 80A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2SMMXANAS-K100-BXX-XXXXXWHVBX1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 100A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2SMMXANAS-K100-KXB-XXXXXRHVBX2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 100A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Red handle, White marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2SMMXANBS-5000-KXB-XXXXXRHVBX2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 50A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Red handle, White marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2SMMXANBS-8000-BXX-XXXXXWHH2X2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 80A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
Part No: D-2SMMXANCS-8000-BXX-XXXXXWH2AX2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Short Time Delay 50/60Hz or DC
- Main Circuit Current: 80A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Horizontal, Line @ Right
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2SMMXASAS-2000-BXX-XXXXXWH1BX2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical Reverse Mounting , Line @ Bottom
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2SMMXBNBS-K110-KXB-XXXXXWHVAX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 110A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2SMMXBRBS-5000-BXX-XXXXXWH1BC1-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 50A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical Reverse Mounting , Line @ Bottom
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: CCC / CRCC
Part No: D-2SMMXBRBS-7000-BXX-XXXXXWH1BC1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 70A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical Reverse Mounting , Line @ Bottom
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2SQ5XASBS-0500-BXX-XXXXXWIVAX2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 5A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2SQ5XCJBS-3000-BXX-XXXXXWIV2C2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2SQAX1NCS-2600-HXX-B1CXXBZHAXZ-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset
- Termination: Stud (M5 or 10-32)
- No of Poles: 1 pole - Metric
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Short Time Delay 50/60Hz or DC
- Main Circuit Current: 26A
- Circuit Configuration: Dual Control - Relay Trip Construction (4 terminal)
- Voltages & Coil Ratings (Dual Control): 24V DC
- Voltages & Coil Ratings (Dual Control): Quick Connect Terminals (0.8mm x 6.35mm)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: Special specify
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: No approvals; Not for Commercial Sale without Prior arrangement with Manufacturer
- Safety marks: Not Applicable
Part No: D-2SR4X1JBS-1200-BXX-XXXXXGIH2X2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 1 pole - Metric
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 12A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Green handle, White marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
Part No: D-2SR4X1JBS-1600-BXX-XXXXXWIH2X2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 1 pole - Metric
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 16A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
Part No: D-2SR4X1JBS-2000-BXX-XXXXXWIH2X2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 1 pole - Metric
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
Part No: D-2SR4X1JBS-3000-BXX-XXXXXWIH2X2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 1 pole - Metric
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2SR4X1SBS-3200-BXX-XXXXXWIH2X2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 1 pole - Metric
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 32A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
Part No: D-2SR4X2JBS-2000-BXX-XXXXXYIH2C2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Tellow hand, Black marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
Part No: D-2SR4X2JBS-3000-BXX-XXXXXRIH2C2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Red handle, White marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2SR4X2JBS-3000-KXB-XXXXXRIH2C2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Red handle, White marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2SR4X2SBS-1600-BXX-XXXXXWIH2C2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 16A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
Part No: D-2SR4X3JBS-2000-BXX-XXXXXRIH2C2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Red handle, White marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2SR4X3JBS-3000-BXX-XXXXXRIH2C2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Red handle, White marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2SR4XBJBS-2000-BXX-XXXXXYIH2C2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Tellow hand, Black marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
Part No: D-2SR4XBSBS-3000-BXX-XXXXXWIH2C2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
Part No: D-2SR5XAJBS-1600-BXX-XXXXXWIH2X2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 16A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
Part No: D-2SR5XAJBS-2000-BXX-XXXXXGIH2X2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Green handle, White marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
Part No: D-2SR5XBJBS-1600-BXX-XXXXXWIH2C2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 16A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
Part No: D-2SR5XCJBS-2000-BXX-XXXXXWIH2C2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2SR5XCJBS-3000-BXX-XXXXXRIH2C2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Red handle, White marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2SRMX1NBS-6000-BXX-XXXXXWIH2X2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 1 pole - Metric
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 60A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
Part No: D-2SRMX1NBS-8000-BXX-XXXXXWIH2X2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 1 pole - Metric
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 80A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
Part No: D-2SW3XBJCS-2500-BXX-XXXXXXXXBC2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Blank Pole - No Handle
- Termination: Push-in Bullet (dia 7.8mm x 16.4mm)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Short Time Delay 50/60Hz or DC
- Main Circuit Current: 25A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2SW3XCJCS-2000-BXX-XXXXXXXXBC2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Blank Pole - No Handle
- Termination: Push-in Bullet (dia 7.8mm x 16.4mm)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Short Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2SW4X2JBS-2000-BXX-XXXXXXXXBC2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Blank Pole - No Handle
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
Part No: D-2SW4X2SBS-1600-BXX-XXXXXXXXBA2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Blank Pole - No Handle
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 16A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-SMALL
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2SW4X2SBS-1600-BXX-XXXXXXXXBC2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Blank Pole - No Handle
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 16A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
Part No: D-2SW4X2SBS-2500-BXX-XXXXXXXXBA2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Blank Pole - No Handle
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 25A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-SMALL
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2SW4XBJBS-2000-BXX-XXXXXXXX2C2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Blank Pole - No Handle
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
Part No: D-2SW4XBSBS-2000-BXX-XXXXXXXXAC2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Blank Pole - No Handle
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2SW4XBSBS-3000-BXX-XXXXXXXXBC2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Blank Pole - No Handle
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
Part No: D-2SW5XBJBS-1600-BXX-XXXXXXXXBC2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Blank Pole - No Handle
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 16A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
Part No: D-2SW5XBJBS-2000-BXX-XXXXXXXXBC1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Blank Pole - No Handle
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2SW5XBSAS-2500-BXX-XXXXXXXXBB2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Blank Pole - No Handle
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 25A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
Pages
If no results are displayed, please adjust your choices on the left. The first selections might be slow, as there are thousands of records to load! As you select, each remaining search parameter will recalculate.
Pages
Add a space between keywords.
Displaying 1401 - 1450 of 2247D-2SMMXANAS-8000-BXX-XXXXXWHVBX1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 80A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2SMMXANAS-K100-BXX-XXXXXWHVBX1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 100A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2SMMXANAS-K100-KXB-XXXXXRHVBX2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 100A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Red handle, White marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2SMMXANBS-5000-KXB-XXXXXRHVBX2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 50A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Red handle, White marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2SMMXANBS-8000-BXX-XXXXXWHH2X2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 80A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
D-2SMMXANCS-8000-BXX-XXXXXWH2AX2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Short Time Delay 50/60Hz or DC
- Main Circuit Current: 80A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Horizontal, Line @ Right
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2SMMXASAS-2000-BXX-XXXXXWH1BX2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical Reverse Mounting , Line @ Bottom
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2SMMXBNBS-K110-KXB-XXXXXWHVAX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 110A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2SMMXBRBS-5000-BXX-XXXXXWH1BC1-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 50A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical Reverse Mounting , Line @ Bottom
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: CCC / CRCC
D-2SMMXBRBS-7000-BXX-XXXXXWH1BC1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 70A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical Reverse Mounting , Line @ Bottom
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2SQ5XASBS-0500-BXX-XXXXXWIVAX2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 5A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2SQ5XCJBS-3000-BXX-XXXXXWIV2C2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2SQAX1NCS-2600-HXX-B1CXXBZHAXZ-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset
- Termination: Stud (M5 or 10-32)
- No of Poles: 1 pole - Metric
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Short Time Delay 50/60Hz or DC
- Main Circuit Current: 26A
- Circuit Configuration: Dual Control - Relay Trip Construction (4 terminal)
- Voltages & Coil Ratings (Dual Control): 24V DC
- Voltages & Coil Ratings (Dual Control): Quick Connect Terminals (0.8mm x 6.35mm)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: Special specify
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: No approvals; Not for Commercial Sale without Prior arrangement with Manufacturer
- Safety marks: Not Applicable
D-2SR4X1JBS-1200-BXX-XXXXXGIH2X2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 1 pole - Metric
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 12A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Green handle, White marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
D-2SR4X1JBS-1600-BXX-XXXXXWIH2X2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 1 pole - Metric
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 16A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
D-2SR4X1JBS-2000-BXX-XXXXXWIH2X2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 1 pole - Metric
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
D-2SR4X1JBS-3000-BXX-XXXXXWIH2X2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 1 pole - Metric
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2SR4X1SBS-3200-BXX-XXXXXWIH2X2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 1 pole - Metric
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 32A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
D-2SR4X2JBS-2000-BXX-XXXXXYIH2C2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Tellow hand, Black marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
D-2SR4X2JBS-3000-BXX-XXXXXRIH2C2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Red handle, White marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2SR4X2JBS-3000-KXB-XXXXXRIH2C2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Red handle, White marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2SR4X2SBS-1600-BXX-XXXXXWIH2C2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 16A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
D-2SR4X3JBS-2000-BXX-XXXXXRIH2C2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Red handle, White marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2SR4X3JBS-3000-BXX-XXXXXRIH2C2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Red handle, White marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2SR4XBJBS-2000-BXX-XXXXXYIH2C2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Tellow hand, Black marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
D-2SR4XBSBS-3000-BXX-XXXXXWIH2C2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
D-2SR5XAJBS-1600-BXX-XXXXXWIH2X2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 16A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
D-2SR5XAJBS-2000-BXX-XXXXXGIH2X2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Green handle, White marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
D-2SR5XBJBS-1600-BXX-XXXXXWIH2C2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 16A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
D-2SR5XCJBS-2000-BXX-XXXXXWIH2C2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2SR5XCJBS-3000-BXX-XXXXXRIH2C2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Red handle, White marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2SRMX1NBS-6000-BXX-XXXXXWIH2X2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 1 pole - Metric
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 60A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
D-2SRMX1NBS-8000-BXX-XXXXXWIH2X2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush rocker handle, Push to Reset- Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 1 pole - Metric
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 80A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Push to Reset and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
D-2SW3XBJCS-2500-BXX-XXXXXXXXBC2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Blank Pole - No Handle
- Termination: Push-in Bullet (dia 7.8mm x 16.4mm)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Short Time Delay 50/60Hz or DC
- Main Circuit Current: 25A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2SW3XCJCS-2000-BXX-XXXXXXXXBC2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Blank Pole - No Handle
- Termination: Push-in Bullet (dia 7.8mm x 16.4mm)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Short Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2SW4X2JBS-2000-BXX-XXXXXXXXBC2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Blank Pole - No Handle
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
D-2SW4X2SBS-1600-BXX-XXXXXXXXBA2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Blank Pole - No Handle
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 16A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-SMALL
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2SW4X2SBS-1600-BXX-XXXXXXXXBC2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Blank Pole - No Handle
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 16A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
D-2SW4X2SBS-2500-BXX-XXXXXXXXBA2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Blank Pole - No Handle
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 25A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-SMALL
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2SW4XBJBS-2000-BXX-XXXXXXXX2C2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Blank Pole - No Handle
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking, Rocker Handle, Test Button
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
D-2SW4XBSBS-2000-BXX-XXXXXXXXAC2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Blank Pole - No Handle
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2SW4XBSBS-3000-BXX-XXXXXXXXBC2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Blank Pole - No Handle
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
D-2SW5XBJBS-1600-BXX-XXXXXXXXBC2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Blank Pole - No Handle
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 16A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
D-2SW5XBJBS-2000-BXX-XXXXXXXXBC1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Blank Pole - No Handle
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2SW5XBSAS-2500-BXX-XXXXXXXXBB2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Blank Pole - No Handle
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 25A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
D-2SW5XCJBS-2000-BXX-XXXXXXXXBC2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Blank Pole - No Handle
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2SW5XCJBS-3000-BXX-XXXXXXXXBC2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Blank Pole - No Handle
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2SWAXBJBS-4000-BXX-XXXXXXXXBC1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Blank Pole - No Handle
- Termination: Stud (M5 or 10-32)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 40A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2SWAXBJBS-6000-BXX-XXXXXXXXBC1-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Blank Pole - No Handle
- Termination: Stud (M5 or 10-32)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 60A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: CCC / CRCC
D-2SWAXBRAS-3000-BXX-XXXXXXXXBX1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Blank Pole - No Handle
- Termination: Stud (M5 or 10-32)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable