info@cbibreakers.com  🗲 salesasia@cbi-electric.com (Asia)
600 Eagleview Blvd, Exton, PA 19341  🗲  +1 610 524 9949

No of Poles

Current Rating

Voltage Rating AC

Voltage Rating DC

Frequency

Circuit Type

Mounting

Actuator Handle

Termination

Trip Characteristics

Filter by frame:

CBi Search: A-Z List

This searchable catalog shows pre-configured, popular products already in our system.

For custom configurations, please contact us. We recommend that you identify products closest to your requirements, and then order a sample noting your custom configuration. Our representative will contact you.

HTabGroup

A - Z (Full Detail)
Displaying 281 - 290 of 2252

If no results are displayed, please adjust your choices on the left. The first selections might be slow, as there are thousands of records to load! As you select, each remaining search parameter will recalculate.

BDH1PA-B0DXBI-0800X-X11

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
6 - 15 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Snap In
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Medium
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I - O)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
  • Main Circuit Current Ratings: 8A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Order Sample

BDH1PA-B0DXBI-1000X-X12

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
6 - 15 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Snap In
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Medium
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I - O)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark
Order Sample

BDH1PA-B0DXBI-1200X-X12

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
6 - 15 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Snap In
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Medium
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I - O)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
  • Main Circuit Current Ratings: 12A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark
Order Sample

BDH1PA-B0DXBI-1500X-X11

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
6 - 15 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Snap In
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Medium
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I - O)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Order Sample

BDH1PA-B0DXBI-2000X-XXX

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
16 - 30 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Snap In
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Medium
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I - O)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable
Order Sample

BDH1PA-B0JXBS-1600X-X12

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
16 - 30 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Snap In
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Medium
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Orange (I - O)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 16A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark
Order Sample

BDH1PA-B0JXBS-2000X-X11

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
16 - 30 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Snap In
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Medium
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Orange (I - O)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Order Sample

BDH1PA-B0JXBS-3000X-X12

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
16 - 30 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Snap In
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Medium
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Orange (I - O)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 30A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark
Order Sample

BDH1PA-B0KXAI-1500X-X12

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
6 - 15 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Snap In
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Slow
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (I/0 & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark
Order Sample

BDH1PA-B0KXAI-2000X-X11

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
16 - 30 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Snap In
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Slow
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (I/0 & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Order Sample

Pages

Accordion View
Displaying 1401 - 1450 of 2252

If no results are displayed, please adjust your choices on the left. The first selections might be slow, as there are thousands of records to load! As you select, each remaining search parameter will recalculate.

Part No: D-2SMMX3RBH-4000-BXX-XXXXXWHHB31-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz
  • Main Circuit Current: 40A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier and Terminal Cover-LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

Part No: D-2SMMX3RBH-7000-HXX-A5EXXGGHA31-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz
  • Main Circuit Current: 70A
  • Circuit Configuration: Dual Control - Relay Trip Construction (4 terminal)
  • Voltages & Coil Ratings (Dual Control): 220-240V AC 50/60Hz
  • Voltages & Coil Ratings (Dual Control): Stud Terminals (M5 / 10-32)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Green handle, White marking
  • Handle Marking: On - Off and Amp rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier and Terminal Cover-LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

Part No: D-2SMMXANAS-4000-BXX-XXXXXWHVBX1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 40A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

Part No: D-2SMMXANAS-5000-BXX-XXXXXWHVBX1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

Part No: D-2SMMXANAS-6000-BXX-XXXXXWHVBX1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 60A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

Part No: D-2SMMXANAS-8000-BXX-XXXXXWHVBX1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 80A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

Part No: D-2SMMXANAS-K100-BXX-XXXXXWHVBX1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 100A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

Part No: D-2SMMXANAS-K100-KXB-XXXXXRHVBX2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 100A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Red handle, White marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2SMMXANBS-5000-KXB-XXXXXRHVBX2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Red handle, White marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2SMMXANBS-8000-BXX-XXXXXWHH2X2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 80A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

Part No: D-2SMMXANCS-8000-BXX-XXXXXWH2AX2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Short Time Delay 50/60Hz or DC
  • Main Circuit Current: 80A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Right
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2SMMXASAS-2000-BXX-XXXXXWH1BX2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical Reverse Mounting , Line @ Bottom
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2SMMXBNBS-K110-KXB-XXXXXWHVAX3-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 110A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: UL listed (UL489A), IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2SMMXBRBS-5000-BXX-XXXXXWH1BC1-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical Reverse Mounting , Line @ Bottom
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

Part No: D-2SMMXBRBS-7000-BXX-XXXXXWH1BC1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 70A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical Reverse Mounting , Line @ Bottom
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

Part No: D-2SQ5XASBS-0500-BXX-XXXXXWIVAX2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset
  • Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 5A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2SQ5XCJBS-3000-BXX-XXXXXWIV2C2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset
  • Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2SQAX1NCS-2600-HXX-B1CXXBZHAXZ-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 1 pole - Metric
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Short Time Delay 50/60Hz or DC
  • Main Circuit Current: 26A
  • Circuit Configuration: Dual Control - Relay Trip Construction (4 terminal)
  • Voltages & Coil Ratings (Dual Control): 24V DC
  • Voltages & Coil Ratings (Dual Control): Quick Connect Terminals (0.8mm x 6.35mm)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: Special specify
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: No approvals; Not for Commercial Sale without Prior arrangement with Manufacturer
  • Safety marks: Not Applicable

Part No: D-2SR4X1JBS-1200-BXX-XXXXXGIH2X2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 1 pole - Metric
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 12A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Green handle, White marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

Part No: D-2SR4X1JBS-1600-BXX-XXXXXWIH2X2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 1 pole - Metric
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 16A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

Part No: D-2SR4X1JBS-2000-BXX-XXXXXWIH2X2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 1 pole - Metric
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

Part No: D-2SR4X1JBS-3000-BXX-XXXXXWIH2X2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 1 pole - Metric
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2SR4X1SBS-3200-BXX-XXXXXWIH2X2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 1 pole - Metric
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 32A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

Part No: D-2SR4X2JBS-2000-BXX-XXXXXYIH2C2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Tellow hand, Black marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

Part No: D-2SR4X2JBS-3000-BXX-XXXXXRIH2C2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Red handle, White marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2SR4X2JBS-3000-KXB-XXXXXRIH2C2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Red handle, White marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2SR4X2SBS-1600-BXX-XXXXXWIH2C2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 16A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

Part No: D-2SR4X3JBS-2000-BXX-XXXXXRIH2C2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Red handle, White marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2SR4X3JBS-3000-BXX-XXXXXRIH2C2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Red handle, White marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2SR4XBJBS-2000-BXX-XXXXXYIH2C2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Tellow hand, Black marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

Part No: D-2SR4XBSBS-3000-BXX-XXXXXWIH2C2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

Part No: D-2SR5XAJBS-1600-BXX-XXXXXWIH2X2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 16A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

Part No: D-2SR5XAJBS-2000-BXX-XXXXXGIH2X2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Green handle, White marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

Part No: D-2SR5XBJBS-1600-BXX-XXXXXWIH2C2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 16A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

Part No: D-2SR5XCJBS-2000-BXX-XXXXXWIH2C2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2SR5XCJBS-3000-BXX-XXXXXRIH2C2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Red handle, White marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2SRMX1NBS-6000-BXX-XXXXXWIH2X2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Metric
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 60A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

Part No: D-2SRMX1NBS-8000-BXX-XXXXXWIH2X2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Metric
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 80A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

Part No: D-2SW3XBJCS-2500-BXX-XXXXXXXXBC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Push-in Bullet (dia 7.8mm x 16.4mm)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Short Time Delay 50/60Hz or DC
  • Main Circuit Current: 25A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2SW3XCJCS-2000-BXX-XXXXXXXXBC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Push-in Bullet (dia 7.8mm x 16.4mm)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Short Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2SW4X2JBS-2000-BXX-XXXXXXXXBC2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

Part No: D-2SW4X2SBS-1600-BXX-XXXXXXXXBA2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 16A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-SMALL
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2SW4X2SBS-1600-BXX-XXXXXXXXBC2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 16A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

Part No: D-2SW4X2SBS-2500-BXX-XXXXXXXXBA2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 25A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-SMALL
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2SW4XBJBS-2000-BXX-XXXXXXXX2C2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

Part No: D-2SW4XBSBS-2000-BXX-XXXXXXXXAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2SW4XBSBS-3000-BXX-XXXXXXXXBC2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

Part No: D-2SW5XBJBS-1600-BXX-XXXXXXXXBC2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 16A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

Part No: D-2SW5XBJBS-2000-BXX-XXXXXXXXBC1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

Part No: D-2SW5XBSAS-2500-BXX-XXXXXXXXBB2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 25A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

Pages

List View
Displaying 841 - 870 of 2252

If no results are displayed, please adjust your choices on the left. The first selections might be slow, as there are thousands of records to load! As you select, each remaining search parameter will recalculate.

Part No No of Poles Framesort descending View/Order Termination
C-BCA21BSAS-1600-BXX-XXXXXBHVAC2-C 2 C-Frame Screw: bus
C-BCA21ASAS-1500-KXB-XXXXXBHVAX2-C 1 C-Frame Screw: bus
C-BCA21ASAS-0500-KXB-XXXXXBHVAX2-C 1 C-Frame Screw: bus
C-BCA21ASAS-2000-KXB-XXXXXBHVAX2-C 1 C-Frame Screw: bus
C-BCA21BSAS-2000-KXB-XXXXXBHVBC2-C 2 C-Frame Screw: bus
C-BCA21BSAS-2000-BXX-XXXXXBHVBC2-C 2 C-Frame Screw: bus
C-BCA22CJAS-5000-KXB-XXXXXWHVBC1-C 3 C-Frame Screw: bus
C-BCA22CJAS-5000-BXX-XXXXXWHVBC1-C 3 C-Frame Screw: bus
C-BCA22CJAS-4000-KXB-XXXXXWHVBC1-C 3 C-Frame Screw: bus
C-BCA22CJAS-4000-BXX-XXXXXWHVBC1-C 3 C-Frame Screw: bus
C-BSY42CJOX-5000-AXX-XXXXXXXXBC1-X 3 C-Frame Screw: bent, Screw: bus
C-BSH42CJOX-5000-AXX-XXXXXBHVAC1-X 3 C-Frame Screw: bent, Screw: bus
C-BSH21ASBS-2000-BXX-XXXXXBHVBX2-X 1 C-Frame Screw: bus
C-BSH22ANCS-4000-BXX-XXXXXBGVBX2-X 1 C-Frame Screw: bus
C-BSMCXAMBD-3000-BXX-XXXXXRGHBX1-X 1 C-Frame Quick connect
C-BSM321NAS-3000-BXX-XXXXXWHHBX1-X 1 C-Frame Screw: upturned ears
C-BSM22ASBS-2000-BXX-XXXXXWHVBX2-X 1 C-Frame Screw: bus
C-BSM22AGAS-2000-BXX-XXXXXWD1AX1-X 1 C-Frame Screw: bus
C-BSM22AGAS-3000-BXX-XXXXXWD1AX1-X 1 C-Frame Screw: bus
C-BSM32AJAS-2000-BXX-XXXXXWH1BX2-C 1 C-Frame Screw: upturned ears
C-BSM32AJAS-3000-BXX-XXXXXWH1BX2-C 1 C-Frame Screw: upturned ears
C-BSM22AJAS-1500-BXX-XXXXXWHHBX2-C 1 C-Frame Screw: bus
C-BSM22AJAS-2000-BXX-XXXXXWHHBX2-C 1 C-Frame Screw: bus
C-BSM22AKBS-2000-BXX-XXXXXWHVBX1-X 1 C-Frame Screw: bus
C-BSQZZASAS-2000-BXX-XXXXXBI12X2-X 1 C-Frame
C-BSQCXASAS-1500-BXX-XXXXXBI12X2-X 1 C-Frame Quick connect
C-BSQCXBSAS-1500-BXX-XXXXXBI12C2-X 2 C-Frame Quick connect
C-BSYCXBSAS-1500-BXX-XXXXXXXXBC2-X 2 C-Frame Quick connect
C-BSQZZASAS-1000-BXX-XXXXXBI12X2-X 1 C-Frame
C-BSR22ASBS-2000-BXX-XXXXXGI12X2-C 1 C-Frame Screw: bus

Pages

Keyword Search

Add a space between keywords.

Displaying 1401 - 1450 of 2247

D-2SMMXANAS-8000-BXX-XXXXXWHVBX1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 80A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SMMXANAS-K100-BXX-XXXXXWHVBX1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 100A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SMMXANAS-K100-KXB-XXXXXRHVBX2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 100A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Red handle, White marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SMMXANBS-5000-KXB-XXXXXRHVBX2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Red handle, White marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SMMXANBS-8000-BXX-XXXXXWHH2X2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 80A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2SMMXANCS-8000-BXX-XXXXXWH2AX2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Short Time Delay 50/60Hz or DC
  • Main Circuit Current: 80A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Right
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SMMXASAS-2000-BXX-XXXXXWH1BX2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical Reverse Mounting , Line @ Bottom
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SMMXBNBS-K110-KXB-XXXXXWHVAX3-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 110A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: UL listed (UL489A), IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SMMXBRBS-5000-BXX-XXXXXWH1BC1-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical Reverse Mounting , Line @ Bottom
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

D-2SMMXBRBS-7000-BXX-XXXXXWH1BC1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush Rocker Handle - Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 70A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off and Amp Rating
  • Mounting Orientation: Vertical Reverse Mounting , Line @ Bottom
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SQ5XASBS-0500-BXX-XXXXXWIVAX2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset
  • Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 5A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SQ5XCJBS-3000-BXX-XXXXXWIV2C2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset
  • Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SQAX1NCS-2600-HXX-B1CXXBZHAXZ-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 1 pole - Metric
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Short Time Delay 50/60Hz or DC
  • Main Circuit Current: 26A
  • Circuit Configuration: Dual Control - Relay Trip Construction (4 terminal)
  • Voltages & Coil Ratings (Dual Control): 24V DC
  • Voltages & Coil Ratings (Dual Control): Quick Connect Terminals (0.8mm x 6.35mm)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: Special specify
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: No approvals; Not for Commercial Sale without Prior arrangement with Manufacturer
  • Safety marks: Not Applicable

D-2SR4X1JBS-1200-BXX-XXXXXGIH2X2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 1 pole - Metric
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 12A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Green handle, White marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2SR4X1JBS-1600-BXX-XXXXXWIH2X2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 1 pole - Metric
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 16A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2SR4X1JBS-2000-BXX-XXXXXWIH2X2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 1 pole - Metric
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2SR4X1JBS-3000-BXX-XXXXXWIH2X2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 1 pole - Metric
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SR4X1SBS-3200-BXX-XXXXXWIH2X2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 1 pole - Metric
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 32A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2SR4X2JBS-2000-BXX-XXXXXYIH2C2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Tellow hand, Black marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2SR4X2JBS-3000-BXX-XXXXXRIH2C2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Red handle, White marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SR4X2JBS-3000-KXB-XXXXXRIH2C2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Red handle, White marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SR4X2SBS-1600-BXX-XXXXXWIH2C2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 16A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2SR4X3JBS-2000-BXX-XXXXXRIH2C2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Red handle, White marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SR4X3JBS-3000-BXX-XXXXXRIH2C2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Red handle, White marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SR4XBJBS-2000-BXX-XXXXXYIH2C2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Tellow hand, Black marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2SR4XBSBS-3000-BXX-XXXXXWIH2C2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2SR5XAJBS-1600-BXX-XXXXXWIH2X2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 16A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2SR5XAJBS-2000-BXX-XXXXXGIH2X2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Green handle, White marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2SR5XBJBS-1600-BXX-XXXXXWIH2C2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 16A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2SR5XCJBS-2000-BXX-XXXXXWIH2C2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SR5XCJBS-3000-BXX-XXXXXRIH2C2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Red handle, White marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SRMX1NBS-6000-BXX-XXXXXWIH2X2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Metric
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 60A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2SRMX1NBS-8000-BXX-XXXXXWIH2X2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Flush rocker handle, Push to Reset- Two Tone
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Metric
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 80A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: Push to Reset and Amp Rating
  • Mounting Orientation: Horizontal, Line @ Left
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2SW3XBJCS-2500-BXX-XXXXXXXXBC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Push-in Bullet (dia 7.8mm x 16.4mm)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Short Time Delay 50/60Hz or DC
  • Main Circuit Current: 25A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SW3XCJCS-2000-BXX-XXXXXXXXBC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Push-in Bullet (dia 7.8mm x 16.4mm)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Short Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SW4X2JBS-2000-BXX-XXXXXXXXBC2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2SW4X2SBS-1600-BXX-XXXXXXXXBA2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 16A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-SMALL
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SW4X2SBS-1600-BXX-XXXXXXXXBC2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 16A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2SW4X2SBS-2500-BXX-XXXXXXXXBA2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 25A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-SMALL
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SW4XBJBS-2000-BXX-XXXXXXXX2C2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking, Rocker Handle, Test Button
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2SW4XBSBS-2000-BXX-XXXXXXXXAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SW4XBSBS-3000-BXX-XXXXXXXXBC2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2SW5XBJBS-1600-BXX-XXXXXXXXBC2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 16A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2SW5XBJBS-2000-BXX-XXXXXXXXBC1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SW5XBSAS-2500-BXX-XXXXXXXXBB2-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 25A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: CCC / CRCC

D-2SW5XCJBS-2000-BXX-XXXXXXXXBC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SW5XCJBS-3000-BXX-XXXXXXXXBC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SWAXBJBS-4000-BXX-XXXXXXXXBC1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 40A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SWAXBJBS-6000-BXX-XXXXXXXXBC1-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 60A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

D-2SWAXBRAS-3000-BXX-XXXXXXXXBX1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable