This searchable catalog shows pre-configured, popular products already in our system.
For custom configurations, please contact us. We recommend that you identify products closest to your requirements, and then order a sample noting your custom configuration. Our representative will contact you.
HTabGroup
If no results are displayed, please adjust your choices on the left. The first selections might be slow, as there are thousands of records to load! As you select, each remaining search parameter will recalculate.
Part No: D-2AAMXCVBS-K300-BXM-XXXXXBDVAX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Standard Handle
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 60Vdc
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 300A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- Switches: Parallel Bridge Housing - For all Parallel Bridged Poles
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O/On - Off
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2AAMXCVBS-K300-BXX-XXXXXBDVAX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Standard Handle
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 60Vdc
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 300A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O/On - Off
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2AAMXCVBS-K300-HXX-B0CXXBDVAX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Standard Handle
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 60Vdc
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 300A
- Circuit Configuration: Dual Control - Relay Trip Construction (4 terminal)
- Voltages & Coil Ratings (Dual Control): 12V DC
- Voltages & Coil Ratings (Dual Control): Quick Connect Terminals (0.8mm x 6.35mm)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O/On - Off
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2AAMXCVBS-K300-KXB-XXXXXBDVAX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Standard Handle
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 60Vdc
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 300A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O/On - Off
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2AAV1BNAI-K180-BXM-XXXXXBDVAX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Standard Handle
- Termination: Bridge Terminal - 2 pole parallel M6 or 1/4-20 Stud Terminal
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Long Time Delay 50/60hz or DC (AS + Inertia Delay)
- Main Circuit Current: 180A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- Switches: Parallel Bridge Housing - For all Parallel Bridged Poles
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O/On - Off
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2AAV1BNAI-K180-BXX-XXXXXBDVAX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Standard Handle
- Termination: Bridge Terminal - 2 pole parallel M6 or 1/4-20 Stud Terminal
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Long Time Delay 50/60hz or DC (AS + Inertia Delay)
- Main Circuit Current: 180A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O/On - Off
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2AAV1BNAI-K180-DXX-B1BXXBDVAX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Standard Handle
- Termination: Bridge Terminal - 2 pole parallel M6 or 1/4-20 Stud Terminal
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Long Time Delay 50/60hz or DC (AS + Inertia Delay)
- Main Circuit Current: 180A
- Circuit Configuration: Switch Relay Trip Voltages Snsing - Centre Terminal Construction (4 Terminal)
- Voltages & Coil Ratings (Dual Control): 24V DC
- Voltages & Coil Ratings (Dual Control): Screw Terminals (M5 / 10-32)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O/On - Off
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2AAV1BNAS-K200-BXM-XXXXXBBVAX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Standard Handle
- Termination: Bridge Terminal - 2 pole parallel M6 or 1/4-20 Stud Terminal
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 200A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- Switches: Parallel Bridge Housing - For all Parallel Bridged Poles
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2AAV1BNAS-K200-KXB-XXXXXBBVBX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Standard Handle
- Termination: Bridge Terminal - 2 pole parallel M6 or 1/4-20 Stud Terminal
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 200A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2AAV1BNBS-K150-BXM-XXXXXBDVAX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Standard Handle
- Termination: Bridge Terminal - 2 pole parallel M6 or 1/4-20 Stud Terminal
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 150A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- Switches: Parallel Bridge Housing - For all Parallel Bridged Poles
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O/On - Off
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2AAV1BNBS-K150-BXX-XXXXXBDVAX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Standard Handle
- Termination: Bridge Terminal - 2 pole parallel M6 or 1/4-20 Stud Terminal
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 150A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O/On - Off
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2AAV1BNBS-K175-BXM-XXXXXBDVAX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Standard Handle
- Termination: Bridge Terminal - 2 pole parallel M6 or 1/4-20 Stud Terminal
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 175A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- Switches: Parallel Bridge Housing - For all Parallel Bridged Poles
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O/On - Off
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2AAV1BNCS-K200-BXM-XXXXXBDVAX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Standard Handle
- Termination: Bridge Terminal - 2 pole parallel M6 or 1/4-20 Stud Terminal
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Short Time Delay 50/60Hz or DC
- Main Circuit Current: 200A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- Switches: Parallel Bridge Housing - For all Parallel Bridged Poles
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O/On - Off
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2AAV1BNCS-K200-BXX-XXXXXBDVAX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Standard Handle
- Termination: Bridge Terminal - 2 pole parallel M6 or 1/4-20 Stud Terminal
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Short Time Delay 50/60Hz or DC
- Main Circuit Current: 200A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O/On - Off
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2AAZZBNCS-K150-BXM-XXXXXBDVAX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Standard Handle
- Termination: Special Specify
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Short Time Delay 50/60Hz or DC
- Main Circuit Current: 150A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- Switches: Parallel Bridge Housing - For all Parallel Bridged Poles
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O/On - Off
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2AAZZBNCS-K150-KXZ-XXXXXBDVAX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Standard Handle
- Termination: Special Specify
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Short Time Delay 50/60Hz or DC
- Main Circuit Current: 150A
- Circuit Configuration: Auxiliary Switch
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O/On - Off
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2AAZZBNCS-K200-BXM-XXXXXYDVAX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Standard Handle
- Termination: Special Specify
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Short Time Delay 50/60Hz or DC
- Main Circuit Current: 200A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- Switches: Parallel Bridge Housing - For all Parallel Bridged Poles
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Tellow hand, Black marking
- Handle Marking: I - O/On - Off
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2AAZZBNCS-K200-KXZ-XXXXXYDVAX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Standard Handle
- Termination: Special Specify
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Short Time Delay 50/60Hz or DC
- Main Circuit Current: 200A
- Circuit Configuration: Auxiliary Switch
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Tellow hand, Black marking
- Handle Marking: I - O/On - Off
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2AAZZCNBS-K250-BXM-XXXXXBDVAX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Standard Handle
- Termination: Special Specify
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 250A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- Switches: Parallel Bridge Housing - For all Parallel Bridged Poles
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O/On - Off
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2AAZZCNBS-K250-BXX-XXXXXBDVAX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Standard Handle
- Termination: Special Specify
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 250A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O/On - Off
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2AAZZCNBS-K250-KXZ-XXXXXBDVAX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Standard Handle
- Termination: Special Specify
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 250A
- Circuit Configuration: Auxiliary Switch
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O/On - Off
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2AH3X1NCS-4000-KXA-XXXXXRHVAX2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Flush Rocker Handle
- Termination: Push-in Bullet (dia 7.8mm x 16.4mm)
- No of Poles: 1 pole - Metric
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Short Time Delay 50/60Hz or DC
- Main Circuit Current: 40A
- Circuit Configuration: Auxiliary Switch
- Switches: DB3-Gold Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 0.1A @ 250Vac & 0.1A @ 80Vdc and UL1054 0.1A @ 125/250Vac & 0.1A @ 30Vdc & 0.3A @ 60Vdc)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Red handle, White marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
Part No: D-2AW3XAZZZ-XXXX-ZZX-XXXXXXXXAXZ-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Push-in Bullet (dia 7.8mm x 16.4mm)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: Special Secify
- Time Delay : Special specify
- Main Circuit Current: No current, for voltage trip poles
- Circuit Configuration: Special Specify
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: No approvals; Not for Commercial Sale without Prior arrangement with Manufacturer
- Safety marks: Not Applicable
Part No: D-2AW4X2SAH-1500-BXX-XXXXXXXXBC2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz
- Main Circuit Current: 15A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
Part No: D-2AW4X2SAH-2000-BXX-XXXXXXXXBC2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
Part No: D-2AW4XBSAS-5000-BXX-XXXXXXXXBC2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 50A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
Part No: D-2AW4XBSBS-3000-BXX-XXXXXXXXBC2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
Part No: D-2AW4XCRAS-1000-BXX-XXXXXXXXBB1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 10A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2AW4XCRAS-1800-BXX-XXXXXXXVAB1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 18A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2AW4XCRAS-4000-BXX-XXXXXXXXAB1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 40A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2AWAXBJBS-2000-BXX-XXXXXXXXBC2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Stud (M5 or 10-32)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2AWAXBJBS-3000-BXX-XXXXXXXXBA1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Stud (M5 or 10-32)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-SMALL
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2AWAXBJBS-3000-BXX-XXXXXXXXBC2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Stud (M5 or 10-32)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2AWAXCJBS-2000-BXX-XXXXXXXXBC2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Stud (M5 or 10-32)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2AWAXCJBS-3000-BXX-XXXXXXXXBC2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Stud (M5 or 10-32)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2AWAXCRAS-1500-BXX-XXXXXXXXBB1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Stud (M5 or 10-32)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 15A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2AWAXCRAS-1500-HXX-ZZEXXXXXBB1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Stud (M5 or 10-32)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 15A
- Circuit Configuration: Dual Control - Relay Trip Construction (4 terminal)
- Voltages & Coil Ratings (Dual Control): Special Specify
- Voltages & Coil Ratings (Dual Control): Stud Terminals (M5 / 10-32)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2AWAXDQAI-4000-BXX-XXXXXXXXBB1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Stud (M5 or 10-32)
- No of Poles: 4 pole – Imperial or RAU/LVR + 3 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac
- Time Delay : Long Time Delay 50/60hz or DC (AS + Inertia Delay)
- Main Circuit Current: 40A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2AWAXDQAI-5000-BXX-XXXXXXXXBB1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Stud (M5 or 10-32)
- No of Poles: 4 pole – Imperial or RAU/LVR + 3 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac
- Time Delay : Long Time Delay 50/60hz or DC (AS + Inertia Delay)
- Main Circuit Current: 50A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2AWAXDZOP-XXXX-NXX-B0XXXXXXBB1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Stud (M5 or 10-32)
- No of Poles: 4 pole – Imperial or RAU/LVR + 3 Circuit Breaker poles
- Rated voltages - Main Circuit: Special Secify
- Time Delay : Instantaneous Trip 50/60Hz or DC
- Main Circuit Current: No current, for voltage trip poles
- Circuit Configuration: Series Trip Voltage Sensing
- Voltages & Coil Ratings (Dual Control): 12V DC
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2AWMX3RBS-6000-BXX-XXXXXXXXBC1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 60A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2AWMXBNBS-9000-BXX-XXXXXXXXBX2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 90A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2BA5XCJBS-2500-CXX-C4CXXRDVAX1-X
- Frame: DD-Frame
- Mounting: Snap-in Mount Edge Flush
- Handle Type: Standard Handle
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 25A
- Circuit Configuration: Switch Relay Trip Current Sensing - Centre Terminal Construction (4 Terminal)
- Voltages & Coil Ratings (Dual Control): 0.1 - 20A
- Voltages & Coil Ratings (Dual Control): Quick Connect Terminals (0.8mm x 6.35mm)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Red handle, White marking
- Handle Marking: I - O/On - Off
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2DEMX1NAS-4000-BXX-XXXXXBAVBXZ-X
- Frame: DD-Frame
- Mounting: NOT AVAILABLE
- Handle Type: NOT AVAILABLE
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 1 pole - Metric
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 40A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: No approvals; Not for Commercial Sale without Prior arrangement with Manufacturer
- Safety marks: Not Applicable
Part No: D-2DEMX1NAS-8000-BXX-XXXXXBAVBXZ-X
- Frame: DD-Frame
- Mounting: NOT AVAILABLE
- Handle Type: NOT AVAILABLE
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 1 pole - Metric
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 80A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: No approvals; Not for Commercial Sale without Prior arrangement with Manufacturer
- Safety marks: Not Applicable
Part No: D-2G2LX2RAS-1100-LAX-XXXXXWAVAB1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle - Mid Trip
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 11A
- Circuit Configuration: Mid Trip Handle
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2G2LX2RAS-1100-LBB-XXXXXWAVAB1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle - Mid Trip
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 11A
- Circuit Configuration: Mid Trip Handle and Aux Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2G2LX2RAS-3000-LAX-XXXXXWAVAB1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle - Mid Trip
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Mid Trip Handle
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2G2LX2RAS-3000-LBB-XXXXXWAVAB1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle - Mid Trip
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Mid Trip Handle and Aux Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2G2LX3RAS-0250-LAX-XXXXXWAVAB1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle - Mid Trip
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 2.5A
- Circuit Configuration: Mid Trip Handle
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Pages
If no results are displayed, please adjust your choices on the left. The first selections might be slow, as there are thousands of records to load! As you select, each remaining search parameter will recalculate.
Pages
Add a space between keywords.
Displaying 1301 - 1350 of 2247D-2AAV1BNAI-K180-BXX-XXXXXBDVAX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Standard Handle
- Termination: Bridge Terminal - 2 pole parallel M6 or 1/4-20 Stud Terminal
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Long Time Delay 50/60hz or DC (AS + Inertia Delay)
- Main Circuit Current: 180A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O/On - Off
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2AAV1BNAI-K180-DXX-B1BXXBDVAX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Standard Handle
- Termination: Bridge Terminal - 2 pole parallel M6 or 1/4-20 Stud Terminal
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Long Time Delay 50/60hz or DC (AS + Inertia Delay)
- Main Circuit Current: 180A
- Circuit Configuration: Switch Relay Trip Voltages Snsing - Centre Terminal Construction (4 Terminal)
- Voltages & Coil Ratings (Dual Control): 24V DC
- Voltages & Coil Ratings (Dual Control): Screw Terminals (M5 / 10-32)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O/On - Off
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2AAV1BNAS-K200-BXM-XXXXXBBVAX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Standard Handle
- Termination: Bridge Terminal - 2 pole parallel M6 or 1/4-20 Stud Terminal
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 200A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- Switches: Parallel Bridge Housing - For all Parallel Bridged Poles
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2AAV1BNAS-K200-KXB-XXXXXBBVBX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Standard Handle
- Termination: Bridge Terminal - 2 pole parallel M6 or 1/4-20 Stud Terminal
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 200A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2AAV1BNBS-K150-BXM-XXXXXBDVAX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Standard Handle
- Termination: Bridge Terminal - 2 pole parallel M6 or 1/4-20 Stud Terminal
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 150A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- Switches: Parallel Bridge Housing - For all Parallel Bridged Poles
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O/On - Off
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2AAV1BNBS-K150-BXX-XXXXXBDVAX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Standard Handle
- Termination: Bridge Terminal - 2 pole parallel M6 or 1/4-20 Stud Terminal
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 150A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O/On - Off
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2AAV1BNBS-K175-BXM-XXXXXBDVAX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Standard Handle
- Termination: Bridge Terminal - 2 pole parallel M6 or 1/4-20 Stud Terminal
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 175A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- Switches: Parallel Bridge Housing - For all Parallel Bridged Poles
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O/On - Off
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2AAV1BNCS-K200-BXM-XXXXXBDVAX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Standard Handle
- Termination: Bridge Terminal - 2 pole parallel M6 or 1/4-20 Stud Terminal
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Short Time Delay 50/60Hz or DC
- Main Circuit Current: 200A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- Switches: Parallel Bridge Housing - For all Parallel Bridged Poles
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O/On - Off
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2AAV1BNCS-K200-BXX-XXXXXBDVAX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Standard Handle
- Termination: Bridge Terminal - 2 pole parallel M6 or 1/4-20 Stud Terminal
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Short Time Delay 50/60Hz or DC
- Main Circuit Current: 200A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O/On - Off
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2AAZZBNCS-K150-BXM-XXXXXBDVAX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Standard Handle
- Termination: Special Specify
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Short Time Delay 50/60Hz or DC
- Main Circuit Current: 150A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- Switches: Parallel Bridge Housing - For all Parallel Bridged Poles
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O/On - Off
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2AAZZBNCS-K150-KXZ-XXXXXBDVAX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Standard Handle
- Termination: Special Specify
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Short Time Delay 50/60Hz or DC
- Main Circuit Current: 150A
- Circuit Configuration: Auxiliary Switch
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O/On - Off
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2AAZZBNCS-K200-BXM-XXXXXYDVAX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Standard Handle
- Termination: Special Specify
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Short Time Delay 50/60Hz or DC
- Main Circuit Current: 200A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- Switches: Parallel Bridge Housing - For all Parallel Bridged Poles
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Tellow hand, Black marking
- Handle Marking: I - O/On - Off
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2AAZZBNCS-K200-KXZ-XXXXXYDVAX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Standard Handle
- Termination: Special Specify
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Short Time Delay 50/60Hz or DC
- Main Circuit Current: 200A
- Circuit Configuration: Auxiliary Switch
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Tellow hand, Black marking
- Handle Marking: I - O/On - Off
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2AAZZCNBS-K250-BXM-XXXXXBDVAX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Standard Handle
- Termination: Special Specify
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 250A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- Switches: Parallel Bridge Housing - For all Parallel Bridged Poles
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O/On - Off
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2AAZZCNBS-K250-BXX-XXXXXBDVAX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Standard Handle
- Termination: Special Specify
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 250A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O/On - Off
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2AAZZCNBS-K250-KXZ-XXXXXBDVAX3-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Standard Handle
- Termination: Special Specify
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 250A
- Circuit Configuration: Auxiliary Switch
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O/On - Off
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: UL listed (UL489A), IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2AH3X1NCS-4000-KXA-XXXXXRHVAX2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Flush Rocker Handle
- Termination: Push-in Bullet (dia 7.8mm x 16.4mm)
- No of Poles: 1 pole - Metric
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Short Time Delay 50/60Hz or DC
- Main Circuit Current: 40A
- Circuit Configuration: Auxiliary Switch
- Switches: DB3-Gold Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 0.1A @ 250Vac & 0.1A @ 80Vdc and UL1054 0.1A @ 125/250Vac & 0.1A @ 30Vdc & 0.3A @ 60Vdc)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Red handle, White marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
D-2AW3XAZZZ-XXXX-ZZX-XXXXXXXXAXZ-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Push-in Bullet (dia 7.8mm x 16.4mm)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: Special Secify
- Time Delay : Special specify
- Main Circuit Current: No current, for voltage trip poles
- Circuit Configuration: Special Specify
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: No approvals; Not for Commercial Sale without Prior arrangement with Manufacturer
- Safety marks: Not Applicable
D-2AW4X2SAH-1500-BXX-XXXXXXXXBC2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz
- Main Circuit Current: 15A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
D-2AW4X2SAH-2000-BXX-XXXXXXXXBC2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
D-2AW4XBSAS-5000-BXX-XXXXXXXXBC2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 50A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
D-2AW4XBSBS-3000-BXX-XXXXXXXXBC2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
D-2AW4XCRAS-1000-BXX-XXXXXXXXBB1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 10A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2AW4XCRAS-1800-BXX-XXXXXXXVAB1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 18A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2AW4XCRAS-4000-BXX-XXXXXXXXAB1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 40A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2AWAXBJBS-2000-BXX-XXXXXXXXBC2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Stud (M5 or 10-32)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2AWAXBJBS-3000-BXX-XXXXXXXXBA1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Stud (M5 or 10-32)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-SMALL
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2AWAXBJBS-3000-BXX-XXXXXXXXBC2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Stud (M5 or 10-32)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2AWAXCJBS-2000-BXX-XXXXXXXXBC2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Stud (M5 or 10-32)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2AWAXCJBS-3000-BXX-XXXXXXXXBC2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Stud (M5 or 10-32)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2AWAXCRAS-1500-BXX-XXXXXXXXBB1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Stud (M5 or 10-32)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 15A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2AWAXCRAS-1500-HXX-ZZEXXXXXBB1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Stud (M5 or 10-32)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 15A
- Circuit Configuration: Dual Control - Relay Trip Construction (4 terminal)
- Voltages & Coil Ratings (Dual Control): Special Specify
- Voltages & Coil Ratings (Dual Control): Stud Terminals (M5 / 10-32)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2AWAXDQAI-4000-BXX-XXXXXXXXBB1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Stud (M5 or 10-32)
- No of Poles: 4 pole – Imperial or RAU/LVR + 3 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac
- Time Delay : Long Time Delay 50/60hz or DC (AS + Inertia Delay)
- Main Circuit Current: 40A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2AWAXDQAI-5000-BXX-XXXXXXXXBB1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Stud (M5 or 10-32)
- No of Poles: 4 pole – Imperial or RAU/LVR + 3 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac
- Time Delay : Long Time Delay 50/60hz or DC (AS + Inertia Delay)
- Main Circuit Current: 50A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2AWAXDZOP-XXXX-NXX-B0XXXXXXBB1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Stud (M5 or 10-32)
- No of Poles: 4 pole – Imperial or RAU/LVR + 3 Circuit Breaker poles
- Rated voltages - Main Circuit: Special Secify
- Time Delay : Instantaneous Trip 50/60Hz or DC
- Main Circuit Current: No current, for voltage trip poles
- Circuit Configuration: Series Trip Voltage Sensing
- Voltages & Coil Ratings (Dual Control): 12V DC
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2AWMX3RBS-6000-BXX-XXXXXXXXBC1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 60A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2AWMXBNBS-9000-BXX-XXXXXXXXBX2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Standard Handle
- Handle Type: Blank Pole - No Handle
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 90A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2BA5XCJBS-2500-CXX-C4CXXRDVAX1-X
- Frame: DD-Frame
- Mounting: Snap-in Mount Edge Flush
- Handle Type: Standard Handle
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 25A
- Circuit Configuration: Switch Relay Trip Current Sensing - Centre Terminal Construction (4 Terminal)
- Voltages & Coil Ratings (Dual Control): 0.1 - 20A
- Voltages & Coil Ratings (Dual Control): Quick Connect Terminals (0.8mm x 6.35mm)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Red handle, White marking
- Handle Marking: I - O/On - Off
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2DEMX1NAS-4000-BXX-XXXXXBAVBXZ-X
- Frame: DD-Frame
- Mounting: NOT AVAILABLE
- Handle Type: NOT AVAILABLE
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 1 pole - Metric
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 40A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: No approvals; Not for Commercial Sale without Prior arrangement with Manufacturer
- Safety marks: Not Applicable
D-2DEMX1NAS-8000-BXX-XXXXXBAVBXZ-X
- Frame: DD-Frame
- Mounting: NOT AVAILABLE
- Handle Type: NOT AVAILABLE
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 1 pole - Metric
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 80A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: No approvals; Not for Commercial Sale without Prior arrangement with Manufacturer
- Safety marks: Not Applicable
D-2G2LX2RAS-1100-LAX-XXXXXWAVAB1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle - Mid Trip
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 11A
- Circuit Configuration: Mid Trip Handle
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2G2LX2RAS-1100-LBB-XXXXXWAVAB1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle - Mid Trip
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 11A
- Circuit Configuration: Mid Trip Handle and Aux Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2G2LX2RAS-3000-LAX-XXXXXWAVAB1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle - Mid Trip
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Mid Trip Handle
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2G2LX2RAS-3000-LBB-XXXXXWAVAB1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle - Mid Trip
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Mid Trip Handle and Aux Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2G2LX3RAS-0250-LAX-XXXXXWAVAB1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle - Mid Trip
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 2.5A
- Circuit Configuration: Mid Trip Handle
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2G2LX3RAS-0250-LBB-XXXXXWAVAB1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle - Mid Trip
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 2.5A
- Circuit Configuration: Mid Trip Handle and Aux Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2G2LX3RAS-1300-LAX-XXXXXWAVAZ1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle - Mid Trip
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 13A
- Circuit Configuration: Mid Trip Handle
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Special Specify
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2G2LX3RAS-1300-LBB-XXXXXWAVAZ1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle - Mid Trip
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 13A
- Circuit Configuration: Mid Trip Handle and Aux Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Special Specify
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2G2LX3RAS-1300-LXB-XXXXXWAVAZ1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle - Mid Trip
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 13A
- Circuit Configuration: Mid Trip Handle and Trip Alarm
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Special Specify
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2GALX2RAS-0800-BXX-XXXXXWAVAZ1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 8A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Special Specify
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable