info@cbibreakers.com  🗲 salesasia@cbi-electric.com (Asia)
600 Eagleview Blvd, Exton, PA 19341  🗲  +1 610 524 9949

No of Poles

Current Rating

Voltage Rating AC

Voltage Rating DC

Frequency

Circuit Type

Mounting

Actuator Handle

Termination

Trip Characteristics

Filter by frame:

CBi Search: A-Z List

This searchable catalog shows pre-configured, popular products already in our system.

For custom configurations, please contact us. We recommend that you identify products closest to your requirements, and then order a sample noting your custom configuration. Our representative will contact you.

HTabGroup

A - Z (Full Detail)
Displaying 291 - 300 of 2252

If no results are displayed, please adjust your choices on the left. The first selections might be slow, as there are thousands of records to load! As you select, each remaining search parameter will recalculate.

BDH1PA-B0KXBS-1500X-X11

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
6 - 15 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Snap In
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Medium
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (I/0 & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Order Sample

BDH1PA-B0KXBS-2000X-X11

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
16 - 30 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Snap In
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Medium
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (I/0 & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Order Sample

BDH1PA-B0KXBS-2500X-X11

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
16 - 30 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Snap In
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Medium
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (I/0 & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Order Sample

BDH1PA-B0KXCS-0700X-X11

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
6 - 15 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Snap In
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Fast
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (I/0 & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 7A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Order Sample

BDH1PA-B0KXCS-0800X-X11

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
6 - 15 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Snap In
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Fast
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (I/0 & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 8A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Order Sample

BDH1PA-B0LXAS-1000X-X12

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
6 - 15 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Snap In
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Slow
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark
Order Sample

BDH1PA-B0LXAS-3000X-X11

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
16 - 30 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Snap In
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Slow
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 30A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Order Sample

BDH1PA-B0LXBS-0500X-X12

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
0.1 - 5 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Snap In
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Medium
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark
Order Sample

BDH1PA-B0LXBS-0600X-X11

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
6 - 15 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Snap In
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Medium
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 6A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Order Sample

BDH1PA-B0LXBS-1000X-X11

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
6 - 15 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Snap In
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Medium
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Order Sample

Pages

Accordion View
Displaying 1451 - 1500 of 2252

If no results are displayed, please adjust your choices on the left. The first selections might be slow, as there are thousands of records to load! As you select, each remaining search parameter will recalculate.

Part No: D-2SW5XCJBS-2000-BXX-XXXXXXXXBC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2SW5XCJBS-3000-BXX-XXXXXXXXBC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2SWAXBJBS-4000-BXX-XXXXXXXXBC1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 40A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

Part No: D-2SWAXBJBS-6000-BXX-XXXXXXXXBC1-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 60A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

Part No: D-2SWAXBRAS-3000-BXX-XXXXXXXXBX1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

Part No: D-2SWAXBRAS-3500-BXX-XXXXXXXXBC1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 35A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

Part No: D-2SWAXBRAS-5000-BXX-XXXXXXXXBC1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

Part No: D-2SWAXCJCS-1500-BXX-XXXXXXXXBX2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Short Time Delay 50/60Hz or DC
  • Main Circuit Current: 15A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2SWAXCJCS-1500-KXA-XXXXXXXXBX2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Short Time Delay 50/60Hz or DC
  • Main Circuit Current: 15A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB3-Gold Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 0.1A @ 250Vac & 0.1A @ 80Vdc and UL1054 0.1A @ 125/250Vac & 0.1A @ 30Vdc & 0.3A @ 60Vdc)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2SWAXCRBS-5000-BXX-XXXXXXXXBA1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-SMALL
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

Part No: D-2SWAXCRBS-5000-BXX-XXXXXXXXBC1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

Part No: D-2SWAXCRBS-5000-GXX-A5EXXXXXBA1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Dual Control - Shunt Trip Construction - 3rd Terminal Close to Load Side (3 Terminal)
  • Voltages & Coil Ratings (Dual Control): 220-240V AC 50/60Hz
  • Voltages & Coil Ratings (Dual Control): Stud Terminals (M5 / 10-32)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-SMALL
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

Part No: D-2SWMX3RBH-4000-BXX-XXXXXXXXB31-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz
  • Main Circuit Current: 40A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier and Terminal Cover-LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

Part No: D-2SWMX3RBH-4000-HXX-A5EXXXXXB31-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz
  • Main Circuit Current: 40A
  • Circuit Configuration: Dual Control - Relay Trip Construction (4 terminal)
  • Voltages & Coil Ratings (Dual Control): 220-240V AC 50/60Hz
  • Voltages & Coil Ratings (Dual Control): Stud Terminals (M5 / 10-32)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier and Terminal Cover-LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

Part No: D-2SWMX3RBH-7000-BXX-XXXXXXXXB31-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz
  • Main Circuit Current: 70A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier and Terminal Cover-LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

Part No: D-2SWMXBNBS-K110-HXM-B0DXXXXXBX3-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 110A
  • Circuit Configuration: Dual Control - Relay Trip Construction (4 terminal)
  • Switches: Parallel Bridge Housing - For all Parallel Bridged Poles
  • Voltages & Coil Ratings (Dual Control): 12V DC
  • Voltages & Coil Ratings (Dual Control): Flying Leads (wire terminals)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: UL listed (UL489A), IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-2SWMXBRBS-5000-BXX-XXXXXXXXBC1-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

Part No: D-2SWMXBRBS-7000-BXX-XXXXXXXXBC1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 70A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

Part No: D-2Z03XANZZ-K100-ZZX-XXXXXXXXBX1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: NOT AVAILABLE
  • Handle Type: Blank Pole - No Handle - Raised Front Plate
  • Termination: Push-in Bullet (dia 7.8mm x 16.4mm)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Special specify
  • Main Circuit Current: 100A
  • Circuit Configuration: Special Specify
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

Part No: D-2Z03XANZZ-K125-ZZX-XXXXXXXXBX1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: NOT AVAILABLE
  • Handle Type: Blank Pole - No Handle - Raised Front Plate
  • Termination: Push-in Bullet (dia 7.8mm x 16.4mm)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Special specify
  • Main Circuit Current: 125A
  • Circuit Configuration: Special Specify
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

Part No: D-5AA4XCMAW-2000-BXX-XXXXXWDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: AC & DC Multipole (80Vdc, 240/415Vac & 277/480Vac)
  • Time Delay : Long Time Delay 50/60Hz/DC (AD + Inertia Delay)
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-5AA4XCMAW-3000-BXX-XXXXXWDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: AC & DC Multipole (80Vdc, 240/415Vac & 277/480Vac)
  • Time Delay : Long Time Delay 50/60Hz/DC (AD + Inertia Delay)
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-5AA4XCMBD-0500-BXX-XXXXXWDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: AC & DC Multipole (80Vdc, 240/415Vac & 277/480Vac)
  • Time Delay : Medium Time Delay 50/60Hz/DC
  • Main Circuit Current: 5A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-5AA4XCMBD-0750-BXX-XXXXXWDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: AC & DC Multipole (80Vdc, 240/415Vac & 277/480Vac)
  • Time Delay : Medium Time Delay 50/60Hz/DC
  • Main Circuit Current: 7.5A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-5AA4XCMBD-1000-BXX-XXXXXWDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: AC & DC Multipole (80Vdc, 240/415Vac & 277/480Vac)
  • Time Delay : Medium Time Delay 50/60Hz/DC
  • Main Circuit Current: 10A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-5AA4XCMBD-1500-BXX-XXXXXWDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: AC & DC Multipole (80Vdc, 240/415Vac & 277/480Vac)
  • Time Delay : Medium Time Delay 50/60Hz/DC
  • Main Circuit Current: 15A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-5AA4XCMBD-2000-BXX-XXXXXWDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: AC & DC Multipole (80Vdc, 240/415Vac & 277/480Vac)
  • Time Delay : Medium Time Delay 50/60Hz/DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-5AA4XCMCD-3000-BXX-XXXXXWDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: AC & DC Multipole (80Vdc, 240/415Vac & 277/480Vac)
  • Time Delay : Short Time Delay 50/60Hz/DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-5AAAXDRAH-4000-BXX-XXXXXBDVAC1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 4 pole – Imperial or RAU/LVR + 3 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz
  • Main Circuit Current: 40A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

Part No: D-5AAAXDRAH-4000-KXA-XXXXXBDVAC1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 4 pole – Imperial or RAU/LVR + 3 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz
  • Main Circuit Current: 40A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB3-Gold Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 0.1A @ 250Vac & 0.1A @ 80Vdc and UL1054 0.1A @ 125/250Vac & 0.1A @ 30Vdc & 0.3A @ 60Vdc)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

Part No: D-7AA4XCMAW-2000-BXX-XXXXXWDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: AC & DC Multipole (80Vdc, 240/415Vac & 277/480Vac)
  • Time Delay : Long Time Delay 50/60Hz/DC (AD + Inertia Delay)
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-7AA4XCMAW-3000-BXX-XXXXXWDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: AC & DC Multipole (80Vdc, 240/415Vac & 277/480Vac)
  • Time Delay : Long Time Delay 50/60Hz/DC (AD + Inertia Delay)
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-7AA4XCMBD-0500-BXX-XXXXXWDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: AC & DC Multipole (80Vdc, 240/415Vac & 277/480Vac)
  • Time Delay : Medium Time Delay 50/60Hz/DC
  • Main Circuit Current: 5A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-7AA4XCMBD-0750-BXX-XXXXXWDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: AC & DC Multipole (80Vdc, 240/415Vac & 277/480Vac)
  • Time Delay : Medium Time Delay 50/60Hz/DC
  • Main Circuit Current: 7.5A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-7AA4XCMBD-1000-BXX-XXXXXWDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: AC & DC Multipole (80Vdc, 240/415Vac & 277/480Vac)
  • Time Delay : Medium Time Delay 50/60Hz/DC
  • Main Circuit Current: 10A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-7AA4XCMBD-1500-BXX-XXXXXWDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: AC & DC Multipole (80Vdc, 240/415Vac & 277/480Vac)
  • Time Delay : Medium Time Delay 50/60Hz/DC
  • Main Circuit Current: 15A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-7AA4XCMBD-2000-BXX-XXXXXWDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: AC & DC Multipole (80Vdc, 240/415Vac & 277/480Vac)
  • Time Delay : Medium Time Delay 50/60Hz/DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: D-7AA4XCMCD-3000-BXX-XXXXXWDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: AC & DC Multipole (80Vdc, 240/415Vac & 277/480Vac)
  • Time Delay : Short Time Delay 50/60Hz/DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

Part No: QF--1(18)D110A-----240V6kA

Frame: Q-Frame
  • Frame Type: QF - 18 mm width MCB
  • Switch/Neutral: NOT Switch or Neutral
  • Auxiliary Switch: Auxiliary or Trip alarm not fitted
  • No of Poles: 3
  • Module Width: 18 mm width MCB
  • Mounting: Din Mount 45mm Grey
  • Time Delay: Long delay, high instantaneous trip
  • Current Rating: 10A
  • Mechanism Type: not used (future use)
  • Shunt trip: Shunt trip not fitted
  • Special requirements: Not applicable
  • Special Termination: No special termination
  • Customer specific: Non customer specific
  • Voltage AC: 240V (IEC60947-2) & 277V (UL1077)
  • kA rating: 6kA (IEC60947-2) & 3kA (UL1077)

Part No: QF--1(18)D115A-----240V6kA

Frame: Q-Frame
  • Frame Type: QF - 18 mm width MCB
  • Switch/Neutral: NOT Switch or Neutral
  • Auxiliary Switch: Auxiliary or Trip alarm not fitted
  • No of Poles: 3
  • Module Width: 18 mm width MCB
  • Mounting: Din Mount 45mm Grey
  • Time Delay: Long delay, high instantaneous trip
  • Current Rating: 15A
  • Mechanism Type: not used (future use)
  • Shunt trip: Shunt trip not fitted
  • Special requirements: Not applicable
  • Special Termination: No special termination
  • Customer specific: Non customer specific
  • Voltage AC: 240V (IEC60947-2) & 277V (UL1077)
  • kA rating: 6kA (IEC60947-2) & 3kA (UL1077)

Part No: QF--1(18)D15A-----240V6kA

Frame: Q-Frame
  • Frame Type: QF - 18 mm width MCB
  • Switch/Neutral: NOT Switch or Neutral
  • Auxiliary Switch: Auxiliary or Trip alarm not fitted
  • No of Poles: 3
  • Module Width: 18 mm width MCB
  • Mounting: Din Mount 45mm Grey
  • Time Delay: Long delay, high instantaneous trip
  • Current Rating: 5A
  • Mechanism Type: not used (future use)
  • Shunt trip: Shunt trip not fitted
  • Special requirements: Not applicable
  • Special Termination: No special termination
  • Customer specific: Non customer specific
  • Voltage AC: 240V (IEC60947-2) & 277V (UL1077)
  • kA rating: 6kA (IEC60947-2) & 3kA (UL1077)

Part No: QF--1(18)D210A-----240V6kA

Frame: Q-Frame
  • Frame Type: QF - 18 mm width MCB
  • Switch/Neutral: NOT Switch or Neutral
  • Auxiliary Switch: Auxiliary or Trip alarm not fitted
  • No of Poles: 3
  • Module Width: 18 mm width MCB
  • Mounting: Din Mount 45mm Grey
  • Time Delay: Medium
  • Current Rating: 10A
  • Mechanism Type: not used (future use)
  • Shunt trip: Shunt trip not fitted
  • Special requirements: Not applicable
  • Special Termination: No special termination
  • Customer specific: Non customer specific
  • Voltage AC: 240V (IEC60947-2) & 277V (UL1077)
  • kA rating: 6kA (IEC60947-2) & 3kA (UL1077)

Part No: QF--1(18)D24A-----240V6kA

Frame: Q-Frame
  • Frame Type: QF - 18 mm width MCB
  • Switch/Neutral: NOT Switch or Neutral
  • Auxiliary Switch: Auxiliary or Trip alarm not fitted
  • No of Poles: 3
  • Module Width: 18 mm width MCB
  • Mounting: Din Mount 45mm Grey
  • Time Delay: Medium
  • Current Rating: 4A
  • Mechanism Type: not used (future use)
  • Shunt trip: Shunt trip not fitted
  • Special requirements: Not applicable
  • Special Termination: No special termination
  • Customer specific: Non customer specific
  • Voltage AC: 240V (IEC60947-2) & 277V (UL1077)
  • kA rating: 6kA (IEC60947-2) & 3kA (UL1077)

Part No: QF--1(18)D263A-----240V6kA

Frame: Q-Frame
  • Frame Type: QF - 18 mm width MCB
  • Switch/Neutral: NOT Switch or Neutral
  • Auxiliary Switch: Auxiliary or Trip alarm not fitted
  • No of Poles: 3
  • Module Width: 18 mm width MCB
  • Mounting: Din Mount 45mm Grey
  • Time Delay: Medium
  • Current Rating: 63A
  • Mechanism Type: not used (future use)
  • Shunt trip: Shunt trip not fitted
  • Special requirements: Not applicable
  • Special Termination: No special termination
  • Customer specific: Non customer specific
  • Voltage AC: 240V (IEC60947-2) & 277V (UL1077)
  • kA rating: 6kA (IEC60947-2) & 3kA (UL1077)

Part No: QF--1(18)D910A-----240V6kA

Frame: Q-Frame
  • Frame Type: QF - 18 mm width MCB
  • Switch/Neutral: NOT Switch or Neutral
  • Auxiliary Switch: Auxiliary or Trip alarm not fitted
  • No of Poles: 3
  • Module Width: 18 mm width MCB
  • Mounting: Din Mount 45mm Grey
  • Time Delay: Long delay
  • Current Rating: 10A
  • Mechanism Type: not used (future use)
  • Shunt trip: Shunt trip not fitted
  • Special requirements: Not applicable
  • Special Termination: No special termination
  • Customer specific: Non customer specific
  • Voltage AC: 240V (IEC60947-2) & 277V (UL1077)
  • kA rating: 6kA (IEC60947-2) & 3kA (UL1077)

Part No: QF--2(13)D210A-----415V6kA

Frame: Q-Frame
  • Frame Type: QF - 13 mm Width MCB
  • Switch/Neutral: NOT Switch or Neutral
  • Auxiliary Switch: Auxiliary or Trip alarm not fitted
  • No of Poles: 3
  • Module Width: 13 mm Width MCB
  • Mounting: Din Mount 45mm Grey
  • Time Delay: Medium
  • Current Rating: 10A
  • Mechanism Type: not used (future use)
  • Shunt trip: Shunt trip not fitted
  • Special requirements: not used (future use)
  • Special Termination: No special termination
  • Customer specific: Non customer specific
  • Voltage AC: 415V
  • kA rating: 6kA

Part No: QF--2(13)D213A-----415V6kA

Frame: Q-Frame
  • Frame Type: QF - 13 mm Width MCB
  • Switch/Neutral: NOT Switch or Neutral
  • Auxiliary Switch: Auxiliary or Trip alarm not fitted
  • No of Poles: 3
  • Module Width: 13 mm Width MCB
  • Mounting: Din Mount 45mm Grey
  • Time Delay: Medium
  • Current Rating: 13A
  • Mechanism Type: not used (future use)
  • Shunt trip: Shunt trip not fitted
  • Special requirements: not used (future use)
  • Special Termination: No special termination
  • Customer specific: Non customer specific
  • Voltage AC: 415V
  • kA rating: 6kA

Part No: QF--2(13)DM216A-----415V6kA

Frame: Q-Frame
  • Frame Type: QF - 13 mm Width MCB
  • Switch/Neutral: NOT Switch or Neutral
  • Auxiliary Switch: Auxiliary or Trip alarm not fitted
  • No of Poles: 3
  • Module Width: 13 mm Width MCB
  • Mounting: Dual Mount 57mm Black
  • Time Delay: Medium
  • Current Rating: 16A
  • Mechanism Type: not used (future use)
  • Shunt trip: Shunt trip not fitted
  • Special requirements: not used (future use)
  • Special Termination: No special termination
  • Customer specific: Non customer specific
  • Voltage AC: 415V
  • kA rating: 6kA

Part No: QF--2(13)DM216A--High Shock--415V6kA

Frame: Q-Frame
  • Frame Type: QF - 13 mm Width MCB
  • Switch/Neutral: NOT Switch or Neutral
  • Auxiliary Switch: Auxiliary or Trip alarm not fitted
  • No of Poles: 3
  • Module Width: 13 mm Width MCB
  • Mounting: Dual Mount 57mm Black
  • Time Delay: Medium
  • Current Rating: 16A
  • Mechanism Type: not used (future use)
  • Shunt trip: Shunt trip not fitted
  • Special requirements: High Shock
  • Special Termination: No special termination
  • Customer specific: Non customer specific
  • Voltage AC: 415V
  • kA rating: 6kA

Part No: QF--2(13)DM220A-----415V6kA

Frame: Q-Frame
  • Frame Type: QF - 13 mm Width MCB
  • Switch/Neutral: NOT Switch or Neutral
  • Auxiliary Switch: Auxiliary or Trip alarm not fitted
  • No of Poles: 3
  • Module Width: 13 mm Width MCB
  • Mounting: Dual Mount 57mm Black
  • Time Delay: Medium
  • Current Rating: 20A
  • Mechanism Type: not used (future use)
  • Shunt trip: Shunt trip not fitted
  • Special requirements: not used (future use)
  • Special Termination: No special termination
  • Customer specific: Non customer specific
  • Voltage AC: 415V
  • kA rating: 6kA

Pages

List View
Displaying 871 - 900 of 2252

If no results are displayed, please adjust your choices on the left. The first selections might be slow, as there are thousands of records to load! As you select, each remaining search parameter will recalculate.

Part No No of Poles Framesort descending View/Order Termination
C-BSY31BJCS-2600-BXX-XXXXXXXXBA1-X 2 C-Frame Screw: upturned ears
C-BSR31BJCS-2600-HXX-A4AXXWIV2A1-X 2 C-Frame Screw: upturned ears
C-BSY31BJCS-2000-BXX-XXXXXXXXBA1-X 2 C-Frame Screw: upturned ears
C-BSR31BJCS-2000-HXX-A4AXXWIV2A1-X 2 C-Frame Screw: upturned ears
C-BSY31BJCS-1300-BXX-XXXXXXXXBA1-X 2 C-Frame Screw: upturned ears
C-BSR31BJCS-1300-HXX-A5AXXWIV2A1-X 2 C-Frame Screw: upturned ears
C-BSY31BJCS-1000-BXX-XXXXXXXXBA1-X 2 C-Frame Screw: upturned ears
C-BSR31BJCS-1000-HXX-A5AXXWIV2A1-X 2 C-Frame Screw: upturned ears
C-BSR22BSBS-2000-BXX-XXXXXYI12C2-C 2 C-Frame Screw: bus
C-BSY22BSBS-2000-BXX-XXXXXXXXBC2-C 2 C-Frame Screw: bus
C-BSY22CJBS-3000-BXX-XXXXXXXXBC1-C 3 C-Frame Screw: bus
C-BSR22CJBS-3000-BXX-XXXXXRI12C1-C 3 C-Frame Screw: bus
C-BSY32CJAH-3000-BXX-XXXXXXXXBC1-X 3 C-Frame Screw: upturned ears
C-BSH32CJAH-3000-BXX-XXXXXWC1BC1-X 3 C-Frame Screw: upturned ears
C-BSH221NBS-5000-KXA-XXXXXBH1BX1-X 1 C-Frame Screw: bus
C-BSMCX1NAS-1600-KXA-XXXXXWHVBX1-X 1 C-Frame Quick connect
D-2AAMX2RAE-1600-KXB-XXXXXWDVAB1-C 2 DD-Frame Stud
D-2AAMX3RAE-2000-KXB-XXXXXWDVAB1-C 3 DD-Frame Stud
D-2AAAXCJAS-1500-KXB-XXXXXBDVAC2-X 3 DD-Frame Stud
D-2AAAXCJAS-2000-KXB-XXXXXBDVAC2-C 3 DD-Frame Stud
D-2AAMXANBS-6000-KXB-XXXXXBDVAX2-X 1 DD-Frame Stud
D-2SHMXANBS-8000-KXB-XXXXXRHVAX1-X 1 DD-Frame Stud
D-2AAMXANCI-K100-KXB-XXXXXBDVAX2-X 1 DD-Frame Stud
D-2AAV1BNAS-K200-KXB-XXXXXBBVBX3-X 2 DD-Frame Stud
D-2SMMXANAS-K100-KXB-XXXXXRHVBX2-X 1 DD-Frame Stud
D-2SMAXBRAS-3000-KXB-XXXXXRHVBX1-X 2 DD-Frame Stud
D-2AAMXCRAI-6300-KXB-XXXXXWDVAB1-C 3 DD-Frame Stud
D-2SMAXBRAS-3500-KXB-XXXXXRHVBC1-X 2 DD-Frame Stud
D-2SR4X2JBS-3000-KXB-XXXXXRIH2C2-X 2 DD-Frame Screw: flush
D-2AAAXCRAS-4000-KXB-XXXXXBCVAA4-X 3 DD-Frame Stud

Pages

Keyword Search

Add a space between keywords.

Displaying 1451 - 1500 of 2247

D-2SWAXBRAS-3500-BXX-XXXXXXXXBC1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 35A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SWAXBRAS-5000-BXX-XXXXXXXXBC1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SWAXCJCS-1500-BXX-XXXXXXXXBX2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Short Time Delay 50/60Hz or DC
  • Main Circuit Current: 15A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SWAXCJCS-1500-KXA-XXXXXXXXBX2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
  • Time Delay : Short Time Delay 50/60Hz or DC
  • Main Circuit Current: 15A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB3-Gold Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 0.1A @ 250Vac & 0.1A @ 80Vdc and UL1054 0.1A @ 125/250Vac & 0.1A @ 30Vdc & 0.3A @ 60Vdc)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SWAXCRBS-5000-BXX-XXXXXXXXBA1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-SMALL
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SWAXCRBS-5000-BXX-XXXXXXXXBC1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SWAXCRBS-5000-GXX-A5EXXXXXBA1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Dual Control - Shunt Trip Construction - 3rd Terminal Close to Load Side (3 Terminal)
  • Voltages & Coil Ratings (Dual Control): 220-240V AC 50/60Hz
  • Voltages & Coil Ratings (Dual Control): Stud Terminals (M5 / 10-32)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-SMALL
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SWMX3RBH-4000-BXX-XXXXXXXXB31-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz
  • Main Circuit Current: 40A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier and Terminal Cover-LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SWMX3RBH-4000-HXX-A5EXXXXXB31-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz
  • Main Circuit Current: 40A
  • Circuit Configuration: Dual Control - Relay Trip Construction (4 terminal)
  • Voltages & Coil Ratings (Dual Control): 220-240V AC 50/60Hz
  • Voltages & Coil Ratings (Dual Control): Stud Terminals (M5 / 10-32)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier and Terminal Cover-LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SWMX3RBH-7000-BXX-XXXXXXXXB31-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz
  • Main Circuit Current: 70A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier and Terminal Cover-LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2SWMXBNBS-K110-HXM-B0DXXXXXBX3-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 110A
  • Circuit Configuration: Dual Control - Relay Trip Construction (4 terminal)
  • Switches: Parallel Bridge Housing - For all Parallel Bridged Poles
  • Voltages & Coil Ratings (Dual Control): 12V DC
  • Voltages & Coil Ratings (Dual Control): Flying Leads (wire terminals)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: UL listed (UL489A), IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-2SWMXBRBS-5000-BXX-XXXXXXXXBC1-C

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 50A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: CCC / CRCC

D-2SWMXBRBS-7000-BXX-XXXXXXXXBC1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
  • Handle Type: Blank Pole - No Handle
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Medium Time Delay 50/60Hz or DC
  • Main Circuit Current: 70A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2Z03XANZZ-K100-ZZX-XXXXXXXXBX1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: NOT AVAILABLE
  • Handle Type: Blank Pole - No Handle - Raised Front Plate
  • Termination: Push-in Bullet (dia 7.8mm x 16.4mm)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Special specify
  • Main Circuit Current: 100A
  • Circuit Configuration: Special Specify
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-2Z03XANZZ-K125-ZZX-XXXXXXXXBX1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: NOT AVAILABLE
  • Handle Type: Blank Pole - No Handle - Raised Front Plate
  • Termination: Push-in Bullet (dia 7.8mm x 16.4mm)
  • No of Poles: 1 pole - Imperial
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Special specify
  • Main Circuit Current: 125A
  • Circuit Configuration: Special Specify
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Not Applicable
  • Handle Marking: Not Applicable
  • Mounting Orientation: Not Applicable
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-5AA4XCMAW-2000-BXX-XXXXXWDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: AC & DC Multipole (80Vdc, 240/415Vac & 277/480Vac)
  • Time Delay : Long Time Delay 50/60Hz/DC (AD + Inertia Delay)
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-5AA4XCMAW-3000-BXX-XXXXXWDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: AC & DC Multipole (80Vdc, 240/415Vac & 277/480Vac)
  • Time Delay : Long Time Delay 50/60Hz/DC (AD + Inertia Delay)
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-5AA4XCMBD-0500-BXX-XXXXXWDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: AC & DC Multipole (80Vdc, 240/415Vac & 277/480Vac)
  • Time Delay : Medium Time Delay 50/60Hz/DC
  • Main Circuit Current: 5A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-5AA4XCMBD-0750-BXX-XXXXXWDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: AC & DC Multipole (80Vdc, 240/415Vac & 277/480Vac)
  • Time Delay : Medium Time Delay 50/60Hz/DC
  • Main Circuit Current: 7.5A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-5AA4XCMBD-1000-BXX-XXXXXWDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: AC & DC Multipole (80Vdc, 240/415Vac & 277/480Vac)
  • Time Delay : Medium Time Delay 50/60Hz/DC
  • Main Circuit Current: 10A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-5AA4XCMBD-1500-BXX-XXXXXWDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: AC & DC Multipole (80Vdc, 240/415Vac & 277/480Vac)
  • Time Delay : Medium Time Delay 50/60Hz/DC
  • Main Circuit Current: 15A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-5AA4XCMBD-2000-BXX-XXXXXWDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: AC & DC Multipole (80Vdc, 240/415Vac & 277/480Vac)
  • Time Delay : Medium Time Delay 50/60Hz/DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-5AA4XCMCD-3000-BXX-XXXXXWDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: AC & DC Multipole (80Vdc, 240/415Vac & 277/480Vac)
  • Time Delay : Short Time Delay 50/60Hz/DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-5AAAXDRAH-4000-BXX-XXXXXBDVAC1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 4 pole – Imperial or RAU/LVR + 3 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz
  • Main Circuit Current: 40A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-5AAAXDRAH-4000-KXA-XXXXXBDVAC1-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Stud (M5 or 10-32)
  • No of Poles: 4 pole – Imperial or RAU/LVR + 3 Circuit Breaker poles
  • Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
  • Time Delay : Long Time Delay 50/60Hz
  • Main Circuit Current: 40A
  • Circuit Configuration: Auxiliary Switch
  • Switches: DB3-Gold Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 0.1A @ 250Vac & 0.1A @ 80Vdc and UL1054 0.1A @ 125/250Vac & 0.1A @ 30Vdc & 0.3A @ 60Vdc)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
  • Safety marks: Not Applicable

D-7AA4XCMAW-2000-BXX-XXXXXWDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: AC & DC Multipole (80Vdc, 240/415Vac & 277/480Vac)
  • Time Delay : Long Time Delay 50/60Hz/DC (AD + Inertia Delay)
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-7AA4XCMAW-3000-BXX-XXXXXWDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: AC & DC Multipole (80Vdc, 240/415Vac & 277/480Vac)
  • Time Delay : Long Time Delay 50/60Hz/DC (AD + Inertia Delay)
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-7AA4XCMBD-0500-BXX-XXXXXWDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: AC & DC Multipole (80Vdc, 240/415Vac & 277/480Vac)
  • Time Delay : Medium Time Delay 50/60Hz/DC
  • Main Circuit Current: 5A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-7AA4XCMBD-0750-BXX-XXXXXWDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: AC & DC Multipole (80Vdc, 240/415Vac & 277/480Vac)
  • Time Delay : Medium Time Delay 50/60Hz/DC
  • Main Circuit Current: 7.5A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-7AA4XCMBD-1000-BXX-XXXXXWDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: AC & DC Multipole (80Vdc, 240/415Vac & 277/480Vac)
  • Time Delay : Medium Time Delay 50/60Hz/DC
  • Main Circuit Current: 10A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-7AA4XCMBD-1500-BXX-XXXXXWDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: AC & DC Multipole (80Vdc, 240/415Vac & 277/480Vac)
  • Time Delay : Medium Time Delay 50/60Hz/DC
  • Main Circuit Current: 15A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-7AA4XCMBD-2000-BXX-XXXXXWDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: AC & DC Multipole (80Vdc, 240/415Vac & 277/480Vac)
  • Time Delay : Medium Time Delay 50/60Hz/DC
  • Main Circuit Current: 20A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

D-7AA4XCMCD-3000-BXX-XXXXXWDVAC2-X

Frame: DD-Frame
  • Frame: DD-Frame
  • Mounting: Front Mount, Rectangular Aperture - Standard Handle
  • Handle Type: Standard Handle
  • Termination: Flush Rear Screw Terminal, (M5 or 10-32)
  • No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
  • Rated voltages - Main Circuit: AC & DC Multipole (80Vdc, 240/415Vac & 277/480Vac)
  • Time Delay : Short Time Delay 50/60Hz/DC
  • Main Circuit Current: 30A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: White handle, Black marking
  • Handle Marking: I - O/On - Off
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: Standard Marking, Standard Handle
  • Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
  • Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
  • Safety marks: Not Applicable

QF--1(18)D110A-----240V6kA

Frame: Q-Frame
  • Frame Type: QF - 18 mm width MCB
  • Switch/Neutral: NOT Switch or Neutral
  • Auxiliary Switch: Auxiliary or Trip alarm not fitted
  • No of Poles: 3
  • Module Width: 18 mm width MCB
  • Mounting: Din Mount 45mm Grey
  • Time Delay: Long delay, high instantaneous trip
  • Current Rating: 10A
  • Mechanism Type: not used (future use)
  • Shunt trip: Shunt trip not fitted
  • Special requirements: Not applicable
  • Special Termination: No special termination
  • Customer specific: Non customer specific
  • Voltage AC: 240V (IEC60947-2) & 277V (UL1077)
  • kA rating: 6kA (IEC60947-2) & 3kA (UL1077)

QF--1(18)D115A-----240V6kA

Frame: Q-Frame
  • Frame Type: QF - 18 mm width MCB
  • Switch/Neutral: NOT Switch or Neutral
  • Auxiliary Switch: Auxiliary or Trip alarm not fitted
  • No of Poles: 3
  • Module Width: 18 mm width MCB
  • Mounting: Din Mount 45mm Grey
  • Time Delay: Long delay, high instantaneous trip
  • Current Rating: 15A
  • Mechanism Type: not used (future use)
  • Shunt trip: Shunt trip not fitted
  • Special requirements: Not applicable
  • Special Termination: No special termination
  • Customer specific: Non customer specific
  • Voltage AC: 240V (IEC60947-2) & 277V (UL1077)
  • kA rating: 6kA (IEC60947-2) & 3kA (UL1077)

QF--1(18)D15A-----240V6kA

Frame: Q-Frame
  • Frame Type: QF - 18 mm width MCB
  • Switch/Neutral: NOT Switch or Neutral
  • Auxiliary Switch: Auxiliary or Trip alarm not fitted
  • No of Poles: 3
  • Module Width: 18 mm width MCB
  • Mounting: Din Mount 45mm Grey
  • Time Delay: Long delay, high instantaneous trip
  • Current Rating: 5A
  • Mechanism Type: not used (future use)
  • Shunt trip: Shunt trip not fitted
  • Special requirements: Not applicable
  • Special Termination: No special termination
  • Customer specific: Non customer specific
  • Voltage AC: 240V (IEC60947-2) & 277V (UL1077)
  • kA rating: 6kA (IEC60947-2) & 3kA (UL1077)

QF--1(18)D210A-----240V6kA

Frame: Q-Frame
  • Frame Type: QF - 18 mm width MCB
  • Switch/Neutral: NOT Switch or Neutral
  • Auxiliary Switch: Auxiliary or Trip alarm not fitted
  • No of Poles: 3
  • Module Width: 18 mm width MCB
  • Mounting: Din Mount 45mm Grey
  • Time Delay: Medium
  • Current Rating: 10A
  • Mechanism Type: not used (future use)
  • Shunt trip: Shunt trip not fitted
  • Special requirements: Not applicable
  • Special Termination: No special termination
  • Customer specific: Non customer specific
  • Voltage AC: 240V (IEC60947-2) & 277V (UL1077)
  • kA rating: 6kA (IEC60947-2) & 3kA (UL1077)

QF--1(18)D24A-----240V6kA

Frame: Q-Frame
  • Frame Type: QF - 18 mm width MCB
  • Switch/Neutral: NOT Switch or Neutral
  • Auxiliary Switch: Auxiliary or Trip alarm not fitted
  • No of Poles: 3
  • Module Width: 18 mm width MCB
  • Mounting: Din Mount 45mm Grey
  • Time Delay: Medium
  • Current Rating: 4A
  • Mechanism Type: not used (future use)
  • Shunt trip: Shunt trip not fitted
  • Special requirements: Not applicable
  • Special Termination: No special termination
  • Customer specific: Non customer specific
  • Voltage AC: 240V (IEC60947-2) & 277V (UL1077)
  • kA rating: 6kA (IEC60947-2) & 3kA (UL1077)

QF--1(18)D263A-----240V6kA

Frame: Q-Frame
  • Frame Type: QF - 18 mm width MCB
  • Switch/Neutral: NOT Switch or Neutral
  • Auxiliary Switch: Auxiliary or Trip alarm not fitted
  • No of Poles: 3
  • Module Width: 18 mm width MCB
  • Mounting: Din Mount 45mm Grey
  • Time Delay: Medium
  • Current Rating: 63A
  • Mechanism Type: not used (future use)
  • Shunt trip: Shunt trip not fitted
  • Special requirements: Not applicable
  • Special Termination: No special termination
  • Customer specific: Non customer specific
  • Voltage AC: 240V (IEC60947-2) & 277V (UL1077)
  • kA rating: 6kA (IEC60947-2) & 3kA (UL1077)

QF--1(18)D910A-----240V6kA

Frame: Q-Frame
  • Frame Type: QF - 18 mm width MCB
  • Switch/Neutral: NOT Switch or Neutral
  • Auxiliary Switch: Auxiliary or Trip alarm not fitted
  • No of Poles: 3
  • Module Width: 18 mm width MCB
  • Mounting: Din Mount 45mm Grey
  • Time Delay: Long delay
  • Current Rating: 10A
  • Mechanism Type: not used (future use)
  • Shunt trip: Shunt trip not fitted
  • Special requirements: Not applicable
  • Special Termination: No special termination
  • Customer specific: Non customer specific
  • Voltage AC: 240V (IEC60947-2) & 277V (UL1077)
  • kA rating: 6kA (IEC60947-2) & 3kA (UL1077)

QF--2(13)D210A-----415V6kA

Frame: Q-Frame
  • Frame Type: QF - 13 mm Width MCB
  • Switch/Neutral: NOT Switch or Neutral
  • Auxiliary Switch: Auxiliary or Trip alarm not fitted
  • No of Poles: 3
  • Module Width: 13 mm Width MCB
  • Mounting: Din Mount 45mm Grey
  • Time Delay: Medium
  • Current Rating: 10A
  • Mechanism Type: not used (future use)
  • Shunt trip: Shunt trip not fitted
  • Special requirements: not used (future use)
  • Special Termination: No special termination
  • Customer specific: Non customer specific
  • Voltage AC: 415V
  • kA rating: 6kA

QF--2(13)D213A-----415V6kA

Frame: Q-Frame
  • Frame Type: QF - 13 mm Width MCB
  • Switch/Neutral: NOT Switch or Neutral
  • Auxiliary Switch: Auxiliary or Trip alarm not fitted
  • No of Poles: 3
  • Module Width: 13 mm Width MCB
  • Mounting: Din Mount 45mm Grey
  • Time Delay: Medium
  • Current Rating: 13A
  • Mechanism Type: not used (future use)
  • Shunt trip: Shunt trip not fitted
  • Special requirements: not used (future use)
  • Special Termination: No special termination
  • Customer specific: Non customer specific
  • Voltage AC: 415V
  • kA rating: 6kA

QF--2(13)DM216A-----415V6kA

Frame: Q-Frame
  • Frame Type: QF - 13 mm Width MCB
  • Switch/Neutral: NOT Switch or Neutral
  • Auxiliary Switch: Auxiliary or Trip alarm not fitted
  • No of Poles: 3
  • Module Width: 13 mm Width MCB
  • Mounting: Dual Mount 57mm Black
  • Time Delay: Medium
  • Current Rating: 16A
  • Mechanism Type: not used (future use)
  • Shunt trip: Shunt trip not fitted
  • Special requirements: not used (future use)
  • Special Termination: No special termination
  • Customer specific: Non customer specific
  • Voltage AC: 415V
  • kA rating: 6kA

QF--2(13)DM216A--High Shock--415V6kA

Frame: Q-Frame
  • Frame Type: QF - 13 mm Width MCB
  • Switch/Neutral: NOT Switch or Neutral
  • Auxiliary Switch: Auxiliary or Trip alarm not fitted
  • No of Poles: 3
  • Module Width: 13 mm Width MCB
  • Mounting: Dual Mount 57mm Black
  • Time Delay: Medium
  • Current Rating: 16A
  • Mechanism Type: not used (future use)
  • Shunt trip: Shunt trip not fitted
  • Special requirements: High Shock
  • Special Termination: No special termination
  • Customer specific: Non customer specific
  • Voltage AC: 415V
  • kA rating: 6kA

QF--2(13)DM220A-----415V6kA

Frame: Q-Frame
  • Frame Type: QF - 13 mm Width MCB
  • Switch/Neutral: NOT Switch or Neutral
  • Auxiliary Switch: Auxiliary or Trip alarm not fitted
  • No of Poles: 3
  • Module Width: 13 mm Width MCB
  • Mounting: Dual Mount 57mm Black
  • Time Delay: Medium
  • Current Rating: 20A
  • Mechanism Type: not used (future use)
  • Shunt trip: Shunt trip not fitted
  • Special requirements: not used (future use)
  • Special Termination: No special termination
  • Customer specific: Non customer specific
  • Voltage AC: 415V
  • kA rating: 6kA

QF--2(13)DM220A--High Shock--415V6kA

Frame: Q-Frame
  • Frame Type: QF - 13 mm Width MCB
  • Switch/Neutral: NOT Switch or Neutral
  • Auxiliary Switch: Auxiliary or Trip alarm not fitted
  • No of Poles: 3
  • Module Width: 13 mm Width MCB
  • Mounting: Dual Mount 57mm Black
  • Time Delay: Medium
  • Current Rating: 20A
  • Mechanism Type: not used (future use)
  • Shunt trip: Shunt trip not fitted
  • Special requirements: High Shock
  • Special Termination: No special termination
  • Customer specific: Non customer specific
  • Voltage AC: 415V
  • kA rating: 6kA

QF--2(13)DM22A-----415V6kA

Frame: Q-Frame
  • Frame Type: QF - 13 mm Width MCB
  • Switch/Neutral: NOT Switch or Neutral
  • Auxiliary Switch: Auxiliary or Trip alarm not fitted
  • No of Poles: 3
  • Module Width: 13 mm Width MCB
  • Mounting: Dual Mount 57mm Black
  • Time Delay: Medium
  • Current Rating: 2A
  • Mechanism Type: not used (future use)
  • Shunt trip: Shunt trip not fitted
  • Special requirements: not used (future use)
  • Special Termination: No special termination
  • Customer specific: Non customer specific
  • Voltage AC: 415V
  • kA rating: 6kA

QF--2(18)D210A-----415V6kA

Frame: Q-Frame
  • Frame Type: QF - 18 mm width MCB
  • Switch/Neutral: NOT Switch or Neutral
  • Auxiliary Switch: Auxiliary or Trip alarm not fitted
  • No of Poles: 3
  • Module Width: 18 mm width MCB
  • Mounting: Din Mount 45mm Grey
  • Time Delay: Medium
  • Current Rating: 10A
  • Mechanism Type: not used (future use)
  • Shunt trip: Shunt trip not fitted
  • Special requirements: Not applicable
  • Special Termination: No special termination
  • Customer specific: Non customer specific
  • Voltage AC: 415V (IEC60947-2) 480V (UL1077)
  • kA rating: 6kA (IEC60947-2) & 3kA (UL1077)

QF--2(18)D232A-----415V6kA

Frame: Q-Frame
  • Frame Type: QF - 18 mm width MCB
  • Switch/Neutral: NOT Switch or Neutral
  • Auxiliary Switch: Auxiliary or Trip alarm not fitted
  • No of Poles: 3
  • Module Width: 18 mm width MCB
  • Mounting: Din Mount 45mm Grey
  • Time Delay: Medium
  • Current Rating: 32A
  • Mechanism Type: not used (future use)
  • Shunt trip: Shunt trip not fitted
  • Special requirements: Not applicable
  • Special Termination: No special termination
  • Customer specific: Non customer specific
  • Voltage AC: 415V (IEC60947-2) 480V (UL1077)
  • kA rating: 6kA (IEC60947-2) & 3kA (UL1077)

QF--2(18)D26A-----415V6kA

Frame: Q-Frame
  • Frame Type: QF - 18 mm width MCB
  • Switch/Neutral: NOT Switch or Neutral
  • Auxiliary Switch: Auxiliary or Trip alarm not fitted
  • No of Poles: 3
  • Module Width: 18 mm width MCB
  • Mounting: Din Mount 45mm Grey
  • Time Delay: Medium
  • Current Rating: 6A
  • Mechanism Type: not used (future use)
  • Shunt trip: Shunt trip not fitted
  • Special requirements: Not applicable
  • Special Termination: No special termination
  • Customer specific: Non customer specific
  • Voltage AC: 415V (IEC60947-2) 480V (UL1077)
  • kA rating: 6kA (IEC60947-2) & 3kA (UL1077)