Part No: D-2G2LX3RAS-0250-LBB-XXXXXWAVAB1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle - Mid Trip
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 2.5A
- Circuit Configuration: Mid Trip Handle and Aux Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2G2LX3RAS-1300-LAX-XXXXXWAVAZ1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle - Mid Trip
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 13A
- Circuit Configuration: Mid Trip Handle
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Special Specify
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2G2LX3RAS-1300-LBB-XXXXXWAVAZ1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle - Mid Trip
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 13A
- Circuit Configuration: Mid Trip Handle and Aux Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Special Specify
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2G2LX3RAS-1300-LXB-XXXXXWAVAZ1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle - Mid Trip
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 13A
- Circuit Configuration: Mid Trip Handle and Trip Alarm
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Special Specify
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2GALX2RAS-0800-BXX-XXXXXWAVAZ1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 8A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Special Specify
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2GALX2RAS-0800-KXB-XXXXXWAVAZ1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 8A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Special Specify
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2GALX3QAS-0250-BXX-XXXXXWAVAZ1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 2.5A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Special Specify
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2GALX3QAS-0250-KXB-XXXXXWAVAZ1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 2.5A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Special Specify
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2GALX3RAS-0100-BXX-XXXXXWAVAZ1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 1A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Special Specify
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2GALX3RAS-0100-KXB-XXXXXWAVAZ1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 1A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Special Specify
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2GALX3RAS-0130-BXX-XXXXXWAVAZ1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 1.3A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Special Specify
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2GALX3RAS-0130-KXB-XXXXXWAVAZ1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 1.3A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Special Specify
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2GALX3RAS-0420-BXX-XXXXXWAVAZ1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 4.2A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Special Specify
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2GALX3RAS-0420-KXB-XXXXXWAVAZ1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 4.2A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Special Specify
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2GALX3RAS-3500-BXX-XXXXXWAVAZ1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 35A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Special Specify
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2GALX3RAS-3500-KXB-XXXXXWAVAZ1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 35A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Special Specify
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2S04X2JBS-3000-BXX-XXXXXXXXBC2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Blank Pole - No Handle - Raised Front Plate
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2S04X3JBS-2000-BXX-XXXXXXXXBC2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Blank Pole - No Handle - Raised Front Plate
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2S04X3JBS-3000-BXX-XXXXXXXXBC2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Blank Pole - No Handle - Raised Front Plate
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2SH4X1NAS-4000-KXA-XXXXXBFVBX2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 1 pole - Metric
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 40A
- Circuit Configuration: Auxiliary Switch
- Switches: DB3-Gold Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 0.1A @ 250Vac & 0.1A @ 80Vdc and UL1054 0.1A @ 125/250Vac & 0.1A @ 30Vdc & 0.3A @ 60Vdc)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O and Amp rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
Part No: D-2SH4X2SBS-1600-BXX-XXXXXWGVBA2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 16A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: On - Off and Amp rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-SMALL
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2SH4X2SBS-2500-BXX-XXXXXWGVBA2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 25A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: On - Off and Amp rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-SMALL
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2SH4XAJAS-3000-BXX-XXXXXWHVAX1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2SH5XASBS-0500-BXX-XXXXXWHVAX2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 5A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2SH5XBSAS-2500-BXX-XXXXXBHVBB2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 25A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
Part No: D-2SH5XCJBS-3000-BXX-XXXXXWHVAC2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2SH5XCRBS-3000-BXX-XXXXXBHVAC1-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: CCC / CRCC
Part No: D-2SH5XCRBS-3000-BXX-XXXXXXXXBC1-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: CCC / CRCC
Part No: D-2SHAXBJBS-4000-BXX-XXXXXRHHAC1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle
- Termination: Stud (M5 or 10-32)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 40A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Red handle, White marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2SHAXBJBS-6000-BXX-XXXXXRHHAC1-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle
- Termination: Stud (M5 or 10-32)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 60A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Red handle, White marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: CCC / CRCC
Part No: D-2SHAXCRBS-5000-BXX-XXXXXWH1BA1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle
- Termination: Stud (M5 or 10-32)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 50A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical Reverse Mounting , Line @ Bottom
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-SMALL
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2SHMXANBS-8000-KXB-XXXXXRHVAX1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 80A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Red handle, White marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2SM3X1NCS-K100-KXB-XXXXXWHHBX2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Push-in Bullet (dia 7.8mm x 16.4mm)
- No of Poles: 1 pole - Metric
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Short Time Delay 50/60Hz or DC
- Main Circuit Current: 100A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2SM3XAJCS-1500-MXA-XXXXXWH1AX2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Push-in Bullet (dia 7.8mm x 16.4mm)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Short Time Delay 50/60Hz or DC
- Main Circuit Current: 15A
- Circuit Configuration: Trip Alarm, but no Mid Trip (Reversed Function - Latch Type)
- Switches: DB3-Gold Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 0.1A @ 250Vac & 0.1A @ 80Vdc and UL1054 0.1A @ 125/250Vac & 0.1A @ 30Vdc & 0.3A @ 60Vdc)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical Reverse Mounting , Line @ Bottom
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2SM3XBJCS-2500-MXA-XXXXXWH1AC2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Push-in Bullet (dia 7.8mm x 16.4mm)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Short Time Delay 50/60Hz or DC
- Main Circuit Current: 25A
- Circuit Configuration: Trip Alarm, but no Mid Trip (Reversed Function - Latch Type)
- Switches: DB3-Gold Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 0.1A @ 250Vac & 0.1A @ 80Vdc and UL1054 0.1A @ 125/250Vac & 0.1A @ 30Vdc & 0.3A @ 60Vdc)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical Reverse Mounting , Line @ Bottom
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2SM3XCJCS-2000-MXA-XXXXXWH1AC2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Push-in Bullet (dia 7.8mm x 16.4mm)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Short Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Trip Alarm, but no Mid Trip (Reversed Function - Latch Type)
- Switches: DB3-Gold Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 0.1A @ 250Vac & 0.1A @ 80Vdc and UL1054 0.1A @ 125/250Vac & 0.1A @ 30Vdc & 0.3A @ 60Vdc)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical Reverse Mounting , Line @ Bottom
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2SM4XANBS-1500-BXX-XXXXXWHVAX2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 15A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2SM4XBSBS-2000-BXX-XXXXXWHHAC2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2SM5XAJBS-2000-BXX-XXXXXWHVBX2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
Part No: D-2SM5XBJBS-2000-BXX-XXXXXRHVAC1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Red handle, White marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2SMAXAKAS-5000-KXB-XXXXXRHVBX1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M5 or 10-32)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 240Vac; 277Vac (Single Pole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 50A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Red handle, White marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2SMAXASBS-5000-BXX-XXXXXWHVAX2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M5 or 10-32)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 50A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2SMAXBRAS-3000-KXB-XXXXXRHVBX1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M5 or 10-32)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Red handle, White marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2SMAXBRAS-3500-KXB-XXXXXRHVBC1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M5 or 10-32)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 35A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Red handle, White marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2SMAXBRAS-5000-KXB-XXXXXRHVBC1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M5 or 10-32)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 50A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Red handle, White marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2SMAXCJCS-1500-BXX-XXXXXWH1AX2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M5 or 10-32)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Short Time Delay 50/60Hz or DC
- Main Circuit Current: 15A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical Reverse Mounting , Line @ Bottom
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2SMAXCRBS-5000-BXX-XXXXXRHVAC1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M5 or 10-32)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 50A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Red handle, White marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
Part No: D-2SMMX1NBS-8000-BXX-XXXXXWHVAX2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 1 pole - Metric
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 80A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2SMMX1NBS-8000-KXB-XXXXXWHVAX2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 1 pole - Metric
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 80A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
Part No: D-2SMMX1NCS-8000-KXB-XXXXXWHHBX2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 1 pole - Metric
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Short Time Delay 50/60Hz or DC
- Main Circuit Current: 80A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
Pages
If no results are displayed, please adjust your choices on the left. The first selections might be slow, as there are thousands of records to load! As you select, each remaining search parameter will recalculate.
Pages
Add a space between keywords.
Displaying 1351 - 1400 of 2247D-2GALX2RAS-0800-KXB-XXXXXWAVAZ1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 8A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Special Specify
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2GALX3QAS-0250-BXX-XXXXXWAVAZ1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 2.5A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Special Specify
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2GALX3QAS-0250-KXB-XXXXXWAVAZ1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 2.5A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Special Specify
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2GALX3RAS-0100-BXX-XXXXXWAVAZ1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 1A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Special Specify
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2GALX3RAS-0100-KXB-XXXXXWAVAZ1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 1A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Special Specify
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2GALX3RAS-0130-BXX-XXXXXWAVAZ1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 1.3A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Special Specify
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2GALX3RAS-0130-KXB-XXXXXWAVAZ1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 1.3A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Special Specify
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2GALX3RAS-0420-BXX-XXXXXWAVAZ1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 4.2A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Special Specify
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2GALX3RAS-0420-KXB-XXXXXWAVAZ1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 4.2A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Special Specify
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2GALX3RAS-3500-BXX-XXXXXWAVAZ1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 35A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Special Specify
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2GALX3RAS-3500-KXB-XXXXXWAVAZ1-X
- Frame: DD-Frame
- Mounting: Rail and Surface Mount
- Handle Type: Standard Handle
- Termination: Clamp Terminal 3,5mm - Top and Bottom
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 35A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: Blank no marking
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Special Specify
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2S04X2JBS-3000-BXX-XXXXXXXXBC2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Blank Pole - No Handle - Raised Front Plate
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2S04X3JBS-2000-BXX-XXXXXXXXBC2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Blank Pole - No Handle - Raised Front Plate
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2S04X3JBS-3000-BXX-XXXXXXXXBC2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Blank Pole - No Handle - Raised Front Plate
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2SH4X1NAS-4000-KXA-XXXXXBFVBX2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 1 pole - Metric
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 40A
- Circuit Configuration: Auxiliary Switch
- Switches: DB3-Gold Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 0.1A @ 250Vac & 0.1A @ 80Vdc and UL1054 0.1A @ 125/250Vac & 0.1A @ 30Vdc & 0.3A @ 60Vdc)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O and Amp rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
D-2SH4X2SBS-1600-BXX-XXXXXWGVBA2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 16A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: On - Off and Amp rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-SMALL
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2SH4X2SBS-2500-BXX-XXXXXWGVBA2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Metric or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 25A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: On - Off and Amp rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-SMALL
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2SH4XAJAS-3000-BXX-XXXXXWHVAX1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2SH5XASBS-0500-BXX-XXXXXWHVAX2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 5A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2SH5XBSAS-2500-BXX-XXXXXBHVBB2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 25A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-LARGE (Rail Mount Product use Cropped Barrier)
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
D-2SH5XCJBS-3000-BXX-XXXXXWHVAC2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2SH5XCRBS-3000-BXX-XXXXXBHVAC1-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Black handle, White marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: CCC / CRCC
D-2SH5XCRBS-3000-BXX-XXXXXXXXBC1-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Not Applicable
- Handle Marking: Not Applicable
- Mounting Orientation: Not Applicable
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: CCC / CRCC
D-2SHAXBJBS-4000-BXX-XXXXXRHHAC1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle
- Termination: Stud (M5 or 10-32)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 40A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Red handle, White marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2SHAXBJBS-6000-BXX-XXXXXRHHAC1-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle
- Termination: Stud (M5 or 10-32)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 60A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Red handle, White marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: CCC / CRCC
D-2SHAXCRBS-5000-BXX-XXXXXWH1BA1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle
- Termination: Stud (M5 or 10-32)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 50A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical Reverse Mounting , Line @ Bottom
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-SMALL
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2SHMXANBS-8000-KXB-XXXXXRHVAX1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 80A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Red handle, White marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2SM3X1NCS-K100-KXB-XXXXXWHHBX2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Push-in Bullet (dia 7.8mm x 16.4mm)
- No of Poles: 1 pole - Metric
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Short Time Delay 50/60Hz or DC
- Main Circuit Current: 100A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2SM3XAJCS-1500-MXA-XXXXXWH1AX2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Push-in Bullet (dia 7.8mm x 16.4mm)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Short Time Delay 50/60Hz or DC
- Main Circuit Current: 15A
- Circuit Configuration: Trip Alarm, but no Mid Trip (Reversed Function - Latch Type)
- Switches: DB3-Gold Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 0.1A @ 250Vac & 0.1A @ 80Vdc and UL1054 0.1A @ 125/250Vac & 0.1A @ 30Vdc & 0.3A @ 60Vdc)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical Reverse Mounting , Line @ Bottom
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2SM3XBJCS-2500-MXA-XXXXXWH1AC2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Push-in Bullet (dia 7.8mm x 16.4mm)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Short Time Delay 50/60Hz or DC
- Main Circuit Current: 25A
- Circuit Configuration: Trip Alarm, but no Mid Trip (Reversed Function - Latch Type)
- Switches: DB3-Gold Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 0.1A @ 250Vac & 0.1A @ 80Vdc and UL1054 0.1A @ 125/250Vac & 0.1A @ 30Vdc & 0.3A @ 60Vdc)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical Reverse Mounting , Line @ Bottom
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2SM3XCJCS-2000-MXA-XXXXXWH1AC2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Push-in Bullet (dia 7.8mm x 16.4mm)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Short Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Trip Alarm, but no Mid Trip (Reversed Function - Latch Type)
- Switches: DB3-Gold Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 0.1A @ 250Vac & 0.1A @ 80Vdc and UL1054 0.1A @ 125/250Vac & 0.1A @ 30Vdc & 0.3A @ 60Vdc)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical Reverse Mounting , Line @ Bottom
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2SM4XANBS-1500-BXX-XXXXXWHVAX2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 15A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2SM4XBSBS-2000-BXX-XXXXXWHHAC2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Flush Rear Screw Terminal, (M5 or 10-32)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2SM5XAJBS-2000-BXX-XXXXXWHVBX2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
D-2SM5XBJBS-2000-BXX-XXXXXRHVAC1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Double Quick Connect Terminal (0.8mm x 6.35mm)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 20A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Red handle, White marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2SMAXAKAS-5000-KXB-XXXXXRHVBX1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M5 or 10-32)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 240Vac; 277Vac (Single Pole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 50A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Red handle, White marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2SMAXASBS-5000-BXX-XXXXXWHVAX2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M5 or 10-32)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 240/415Vac; 120/240Vac or 240Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 50A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2SMAXBRAS-3000-KXB-XXXXXRHVBX1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M5 or 10-32)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 30A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Red handle, White marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2SMAXBRAS-3500-KXB-XXXXXRHVBC1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M5 or 10-32)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 35A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Red handle, White marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2SMAXBRAS-5000-KXB-XXXXXRHVBC1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M5 or 10-32)
- No of Poles: 2 pole – Imperial or RAU/LVR + 1 Circuit Breaker pole
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 50A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Red handle, White marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2SMAXCJCS-1500-BXX-XXXXXWH1AX2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M5 or 10-32)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240Vac; 120Vac (Single Pole)
- Time Delay : Short Time Delay 50/60Hz or DC
- Main Circuit Current: 15A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical Reverse Mounting , Line @ Bottom
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2SMAXCRBS-5000-BXX-XXXXXRHVAC1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M5 or 10-32)
- No of Poles: 3 pole – Imperial or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 50A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Red handle, White marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier-Z Type LARGE
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2SMMX1NBS-8000-BXX-XXXXXWHVAX2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 1 pole - Metric
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 80A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2SMMX1NBS-8000-KXB-XXXXXWHVAX2-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 1 pole - Metric
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Medium Time Delay 50/60Hz or DC
- Main Circuit Current: 80A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: Not Applicable
D-2SMMX1NCS-8000-KXB-XXXXXWHHBX2-C
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 1 pole - Metric
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Short Time Delay 50/60Hz or DC
- Main Circuit Current: 80A
- Circuit Configuration: Auxiliary Switch
- Switches: DB2-Silver Tips, Equally Spaced Terminals, 2.75mm (0.108") - EN61058 10A @ 250Vac & 0.1A @ 80Vdc and UL1054 10A @ 125/250Vac)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUL, UL listed UL489, IEC/EN60947-2, CE
- Safety marks: CCC / CRCC
D-2SMMX3RBH-4000-BXX-XXXXXWHHB31-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz
- Main Circuit Current: 40A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Inter-Phase Barrier and Terminal Cover-LARGE
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2SMMX3RBH-7000-HXX-A5EXXGGHA31-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 3 pole – Metric or RAU/LVR + 2 Circuit Breaker poles
- Rated voltages - Main Circuit: 240/415Vac; 277/480Vac (Multipole)
- Time Delay : Medium Time Delay 50/60Hz
- Main Circuit Current: 70A
- Circuit Configuration: Dual Control - Relay Trip Construction (4 terminal)
- Voltages & Coil Ratings (Dual Control): 220-240V AC 50/60Hz
- Voltages & Coil Ratings (Dual Control): Stud Terminals (M5 / 10-32)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: Green handle, White marking
- Handle Marking: On - Off and Amp rating
- Mounting Orientation: Horizontal, Line @ Left
- Front Plate Marking: Standard Marking, Standard Handle
- Interphase Barrier or Cover: Inter-Phase Barrier and Terminal Cover-LARGE
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2SMMXANAS-4000-BXX-XXXXXWHVBX1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 40A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2SMMXANAS-5000-BXX-XXXXXWHVBX1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 50A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable
D-2SMMXANAS-6000-BXX-XXXXXWHVBX1-X
- Frame: DD-Frame
- Mounting: Front Mount, Rectangular Aperture - Flush Rocker Handle
- Handle Type: Flush Rocker Handle - Two Tone
- Termination: Stud (M6 or 1/4-20)
- No of Poles: 1 pole - Imperial
- Rated voltages - Main Circuit: 80Vdc
- Time Delay : Long Time Delay 50/60Hz or DC
- Main Circuit Current: 60A
- Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
- RMU - Model: Not Applicable
- Customer Specific: Not Applicable
- Handle Color: White handle, Black marking
- Handle Marking: I - O/On - Off and Amp Rating
- Mounting Orientation: Vertical, Standard Mounting , Line @ Top
- Front Plate Marking: No Marking for Pole without Handle
- Interphase Barrier or Cover: Not Applicable
- Approvals: CUR, UL recognized UL1077, IEC/EN60934, CE
- Safety marks: Not Applicable